The purpose of this article is to review and update the current status of carotid artery stent placement in the world. Surveys to major interventional centers in Europe, North and South America, and Asia were initially completed in June 1997. Subsequent information from these 24 centers in addition to 12 new centers has been obtained to update the information. The survey asked the various questions regarding the patients enrolled, procedure techniques, and results of carotid stenting, including complications and restenosis. The total number of endovascular carotid stent procedures that have been performed worldwide to date included 5,210 procedures involving 4,757 patients. There was a technical success of 98.4% with 5,129 carotid arteries treated. Complications that occurred during the carotid stent placement or within a 30-day period following placement were recorded. Overall, there were 134 transient ischemic attacks (TIAs) for a rate of 2.82%. Based on the total patient population, there were 129 minor strokes with a rate of occurrence of 2.72%. The total number of major strokes was 71 for a rate of 1.49%. There were 41 deaths within a 30-day postprocedure period resulting in a mortality rate of 0.86%. The combined minor and major strokes and procedure-related death rate was 5.07%. Restenosis rates of carotid stenting have been 1.99 % and 3.46% at 6 and 12 months, respectively. The rate of neurologic events after stent placement has been 1.42% at 6 -12-month follow-up. Endovascular stent treatment of carotid artery atherosclerotic disease is growing as an alternative for vascular surgery, especially for patients that are high risk for standard carotid endarterectomy. The periprocedure risks for major and minor strokes and death are generally acceptable at this early stage of development and have not changed significantly since the first survey results. Cathet. Cardiovasc. Intervent. 50:160 -167, 2000.
The purpose of this article is to review and update the current status of carotid artery stent placement in the world. Surveys to major interventional centers in Europe, North and South America, and Asia were initially completed in June 1997. Subsequent information from these 24 centers in addition to 12 new centers has been obtained to update the information. The survey asked the various questions regarding the patients enrolled, procedure techniques, and results of carotid stenting, including complications and restenosis. The total number of endovascular carotid stent procedures that have been performed worldwide to date included 5,210 procedures involving 4,757 patients. There was a technical success of 98.4% with 5,129 carotid arteries treated. Complications that occurred during the carotid stent placement or within a 30‐day period following placement were recorded. Overall, there were 134 transient ischemic attacks (TIAs) for a rate of 2.82%. Based on the total patient population, there were 129 minor strokes with a rate of occurrence of 2.72%. The total number of major strokes was 71 for a rate of 1.49%. There were 41 deaths within a 30‐day postprocedure period resulting in a mortality rate of 0.86%. The combined minor and major strokes and procedure‐related death rate was 5.07%. Restenosis rates of carotid stenting have been 1.99% and 3.46% at 6 and 12 months, respectively. The rate of neurologic events after stent placement has been 1.42% at 6–12‐month follow‐up. Endovascular stent treatment of carotid artery atherosclerotic disease is growing as an alternative for vascular surgery, especially for patients that are high risk for standard carotid endarterectomy. The periprocedure risks for major and minor strokes and death are generally acceptable at this early stage of development and have not changed significantly since the first survey results. Cathet. Cardiovasc. Intervent. 50:160–167, 2000. ©2000 Wiley–Liss,Inc.
Background and Purpose-Fear of distal embolization and stroke has aroused concern regarding carotid stenting. Devices to protect the cerebral circulation may make carotid stenting safer. Methods-A multidisciplinary study group tested a balloon occlusion-aspiration emboli entrapment device in conjunction with carotid stenting. The device consists of an elastomeric balloon on a steerable wire with a detachable adapter that inflates and deflates the distal temporary occlusion balloon. An aspiration catheter is used to remove trapped emboli after stenting and before occlusion balloon deflation. Results-Seventy-five patients with severe internal carotid artery stenosis were treated with stents deployed with this cerebrovasculature protection system. All 75 patients (100%) had grossly visible particulate material aspirated, and all were treated successfully without major or minor stroke or death at 30 days. Preintervention stenosis was 81Ϯ10%, and residual stenosis was 5Ϯ7%. Nine patients (12%) had angiographic evidence of thrombus before intervention, but no patient had thrombus or vessel cutoff after the procedure. Four patients (5%) developed transient neurological symptoms during protection balloon occlusion, but symptoms resolved with balloon deflation. The 22 to 667 particles aspirated per patient ranged from 3.6 to 5262 m in maximum diameter (mean, 203Ϯ256 m). These particles included fibrous plaque debris, lipid or cholesterol vacuoles, and calcific plaque fragments. Conclusions-Protected carotid stenting was performed successfully and safely in this study early in the experience with cerebrovascular protection devices. Particulate emboli are frequent with stenting, and cerebral protection will likely be necessary to minimize stroke. Randomized trials comparing protected carotid stenting with endarterectomy are warranted.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.