In total, 17 pediatric patients with hematologic malignancies (n ¼ 14) and Fanconi anemia (FA) (n ¼ 3) underwent haploidentical SCT with T-cell depletion. The patients were conditioned with reduced-intensity regimens, and CYA was used for GVHD prophylaxis. Successful engraftment occurred in 16 patients (94%). One patient failed to achieve a primary engraftment. Another patient rejected the first SCT after 10 weeks and had a successful second transplant. Of all engrafted patients, only one developed severe acute GVHD. Ten patients were alive at a median follow-up of 18 months (range, 5-62 months). The 5-years' OS was 53.8%. The three patients with FA are currently well with full-donor chimerism at 16, 6 and 5 months post transplant, respectively. The OS of 14 patients with high-risk hematologic malignancies was 47.6%. Three patients died as a result of post transplant leukemia relapse. CMV infection, GVHD and organ injury were other causes of mortality. Haploidentical SCT was found to be an alternative feasible treatment in Uruguay for patients who need allogenic transplantation but lack an HLA-identical family donor. It should be considered as an early option in FA patients before transformation or significant exposure to blood products.
Monitoring of minimal residual disease (MRD) by flow cytometry (FCM) is a powerful prognostic tool for predicting outcomes in acute lymphoblastic leukemia (ALL). To apply FCM-MRD in large, collaborative trials, dedicated laboratory staff must be educated to concordantly high levels of expertise and their performance quality should be continuously monitored. We sought to install a unique and comprehensive training and quality control (QC) program involving a large number of reference laboratories within the international Berlin-Frankfurt-Münster (I-BFM) consortium, in order to complement the standardization of the methodology with an educational component and persistent quality control measures. Our QC and quality assurance (QA) program is based on four major cornerstones: (i) a twinning maturation program, (ii) obligatory participation in external QA programs (spiked sample send around, United Kingdom National External Quality Assessment Service (UK NEQAS)), (iii) regular participation in list-mode-data (LMD) file ring trials (FCM data file send arounds), and (iv) surveys of independent data derived from trial results. We demonstrate that the training of laboratories using experienced twinning partners, along with continuous educational feedback significantly improves the performance of laboratories in detecting and quantifying MRD in pediatric ALL patients. Overall, our extensive education and quality control program improved inter-laboratory concordance rates of FCM-MRD assessments and ultimately led to a very high conformity of risk estimates in independent patient cohorts.
Our main goal was to evaluate the CD34+ dose in patients undergoing haemotopoietic stem celltransplantation and its results in terms of recovery of neutrophile and platelet counts, transfusion requirements, days of fever, antibiotic requirements and length of hospital stay. We studied 38 consecutive patients with haematological malignancies transplanted at our Department, from Feb. 96 through Sept. 98. The CD34+ cell quantification technique was standardized, using a modification of the ISAGHE 96 protocol. Patients were sorted into three groups according to the CD34+ count administered: a) between 3 and 5 x 10(6) cells/kg; b) between 5 and 10 x 10(6) cells/kg; c) > 10 x 10(6) CD34+ cells/kg. As a secondary end point, results were assessed according to the number of aphereses required to arrive at the target count of CD34+, separating those patients that required only 1 or 2 aphereses versus those requiring 3 or more. Finally, an analysis was made of the results of transplantation comparing the different sources of stem cells (PBSC versus PBSC + B.M.). The best results were obtained in the group with cells between 3 and 5 x 10(6) CD34+. No statistically significant advantages were found in the group with cells over 5. The supra-optimal dose of more 10 x 10(6) would yield no additional beneficial results, while they can imply a greater infusion of residual tumor cells. The number of aphereses had no impact on engraftment. Results obtained with PBSC transplants were better than those with BM+PBSC in terms of neutrophile and platelet recovery. The number of CD34+ cells remains the main element in stem cell transplantation to evaluate the haematopoietic recovery after engraftment. Minimum and optimum yields remain unclear. Centers should establish their own optimal dose based on local methodologies and outcomes, maximizing costs and benefits.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.