Many procedures in modern clinical medicine rely on the use of electronic implants in treating conditions that range from acute coronary events to traumatic injury. However, standard permanent electronic hardware acts as a nidus for infection: bacteria form biofilms along percutaneous wires, or seed haematogenously, with the potential to migrate within the body and to provoke immune-mediated pathological tissue reactions. The associated surgical retrieval procedures, meanwhile, subject patients to the distress associated with re-operation and expose them to additional complications. Here, we report materials, device architectures, integration strategies, and in vivo demonstrations in rats of implantable, multifunctional silicon sensors for the brain, for which all of the constituent materials naturally resorb via hydrolysis and/or metabolic action, eliminating the need for extraction. Continuous monitoring of intracranial pressure and temperature illustrates functionality essential to the treatment of traumatic brain injury; the measurement performance of our resorbable devices compares favourably with that of non-resorbable clinical standards. In our experiments, insulated percutaneous wires connect to an externally mounted, miniaturized wireless potentiostat for data transmission. In a separate set-up, we connect a sensor to an implanted (but only partially resorbable) data-communication system, proving the principle that there is no need for any percutaneous wiring. The devices can be adapted to sense fluid flow, motion, pH or thermal characteristics, in formats that are compatible with the body's abdomen and extremities, as well as the deep brain, suggesting that the sensors might meet many needs in clinical medicine.
1322 wileyonlinelibrary.com applications in fi elds of healthcare monitoring, human-computer interaction, and electronic skin. [ 12 ] The relative resistance Δ R normalized by the initial resistance R 0 depends on Poisson's ratio ( ν ) and resistivity variation (Δ ρ ) normalized by its initial resistivity ρ 0 through the expression ΔR / R 0 = (1 + 2ν) ε + Δ ρ / ρ 0.[ 13 ] The sensitivity revealed by gauge factor (GF, defi ned as ( ΔR / R 0 )/ ε ) depends on both intrinsic property and structural feature. According to this formula, graphene-based strain sensors have shown low sensitivities due to the rigid and stable structure of intrinsic graphene. [ 14 ] With hardly opened band gap, the GF of a suspended graphene is only about 1.9 under moderate uniaxial strains. [ 15 ] Therefore, structural engineering of graphene is needed to boost the sensitivity of graphene-based strain sensors.Adjustment of the connection channels in graphene is an effective way to alter its resistivity for improved sensitivity in strain sensors. Two common methods for the structural construction of graphene include high temperature processing based chemical vapor deposition (CVD) and solution processing based sheets/fl akes assembly. As for CVD, the resistivity of graphene would be affected by its grain boundary, grain size, and the defect density. [16][17][18] Continuous graphene fi lms grown by CVD could sustain 1% strain with a GF of only 6.1, [ 19 ] and the GF increases to 151 for a 5% strain due to the morphological Large-Area Ultrathin Graphene Films by Single-Step Marangoni Self-Assembly for Highly Sensitive Strain Sensing ApplicationXinming Li , Tingting Yang , Yao Yang , Jia Zhu , Li Li , Fakhr E. Alam , Xiao Li , Kunlin Wang , Huanyu Cheng , Cheng-Te Lin , * Ying Fang , * and Hongwei Zhu * Promoted by the demand for wearable devices, graphene has been proved to be a promising material for potential applications in fl exible and highly sensitive strain sensors. However, low sensitivity and complex processing of graphene retard the development toward the practical applications. Here, an environment-friendly and cost-effective method to fabricate large-area ultrathin graphene fi lms is proposed for highly sensitive fl exible strain sensor. The assembled graphene fi lms are derived rapidly at the liquid/air interface by Marangoni effect and the area can be scaled up. These graphene-based strain sensors exhibit extremely high sensitivity with gauge factor of 1037 at 2% strain, which represents the highest value for graphene platelets at this small deformation so far. This simple fabrication for strain sensors with highly sensitive performance of strain sensor makes it a novel approach to applications in electronic skin, wearable sensors, and health monitoring platforms.
Transparent, stretchable films of carbon nanotubes (CNTs) have attracted significant attention for applications in flexible electronics, while the lack of structural strength in CNT networks leads to deformation and failure under high mechanical load. In this work, enhancement of the strength and load transfer capabilities of CNT networks by chemical vapor deposition of graphene in the nanotube voids is proposed. The graphene hybridization significantly strengthens the CNT networks, especially at nanotube joints, and enhances their resistance to buckling and bundling under large cyclic strain up to 20%. The hybridized films show linear and reproducible responses to tensile strains, which have been applied in strain sensors to detect human motions with fast response, high sensitivity, and durability.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.