Objective. The aim of the study was to compare titration of positive end-expiratory pressure (PEEP) with electrical impedance tomography (EIT) and with ventilator-embedded pressure–volume (PV) loop in moderate to severe acute respiratory distress syndrome (ARDS). Approach. Eighty-seven moderate to severe ARDS patients (arterial oxygen partial pressure to fractional inspired oxygen ratio, PaO2/FiO2 ≤ 200 mmHg) were randomized to either EIT group (n = 42) or PV group (n = 45). All patients received identical medical care using the same general support guidelines and protective mechanical ventilation. In the EIT group, the selected PEEP equaled the airway pressure at the intercept between cumulated collapse and overdistension percentages curves and in the PV group, at the pressure where maximal hysteresis was reached. Main results. Baseline characteristics and settings were comparable between the groups. After optimization, PEEP was significantly higher in the PV group (17.4 ± 1.7 versus 16.2 ± 2.6 cmH2O, PV versus EIT groups, p = 0.02). After 48 h, driving pressure was significantly higher in the PV group (12.4 ± 3.6 versus 10.9 ± 2.5 cmH2O, p = 0.04). Lung mechanics and oxygenation were better in the EIT group but did not statistically differ between the groups. The survival rate was lower in the PV group (44.4% versus 69.0%, p = 0.02; hazard ratio 2.1, confidence interval 1·1–3.9). None of the other pre-specified exploratory clinical endpoints were significantly different. Significance. In moderate to severe ARDS, PEEP titration guided with EIT, compared with PV curve, might be associated with improved driving pressure and survival rate.
Trial registration: NCT03112512, 13 April, 2017.
Background
Clinical management of COVID-19 requires close monitoring of lung function. While computed tomography (CT) offers ideal way to identify the phenotypes, it cannot monitor the patient response to therapeutic interventions. We present a case of ventilation management for a COVID-19 patient where electrical impedance tomography (EIT) was used to personalize care.
Case presentation
The patient developed acute respiratory distress syndrome, required invasive mechanical ventilation, and was subsequently weaned. EIT was used multiple times: to titrate the positive end-expiratory pressure, understand the influence of body position, and guide the support levels during weaning and after extubation. We show how EIT provides bedside monitoring of the patient´s response to various therapeutic interventions and helps guide treatments.
Conclusion
EIT provides unique information that may help the ventilation management in the pandemic of COVID-19.
Compliance with the SRB for patients developing septic shock in the general medical wards is very low. Besides providing educational programs to improve awareness and acceptance of the SRB, measures to help in central venous catheterization and completion of SRB may be considered.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.