Fluorescent microscopy and flow cytometry are widely used tools in biomedical sciences. Cost-effective translation of these technologies to remote and resource-limited environments could create new opportunities especially for telemedicine applications. Toward this direction, here we demonstrate the integration of imaging cytometry and fluorescent microscopy on a cell phone using a compact, lightweight, and cost-effective optofluidic attachment. In this cell-phone-based optofluidic imaging cytometry platform, fluorescently labeled particles or cells of interest are continuously delivered to our imaging volume through a disposable microfluidic channel that is positioned above the existing camera unit of the cell phone. The same microfluidic device also acts as a multilayered optofluidic waveguide and efficiently guides our excitation light, which is butt-coupled from the side facets of our microfluidic channel using inexpensive light-emitting diodes. Since the excitation of the sample volume occurs through guided waves that propagate perpendicular to the detection path, our cell-phone camera can record fluorescent movies of the specimens as they are flowing through the microchannel. The digital frames of these fluorescent movies are then rapidly processed to quantify the count and the density of the labeled particles/cells within the target solution of interest. We tested the performance of our cell-phone-based imaging cytometer by measuring the density of white blood cells in human blood samples, which provided a decent match to a commercially available hematology analyzer. We further characterized the imaging quality of the same platform to demonstrate a spatial resolution of ~2 μm. This cell-phone-enabled optofluidic imaging flow cytometer could especially be useful for rapid and sensitive imaging of bodily fluids for conducting various cell counts (e.g., toward monitoring of HIV+ patients) or rare cell analysis as well as for screening of water quality in remote and resource-poor settings.
We demonstrate wide-field fluorescent and darkfield imaging on a cell-phone with compact, lightweight and cost-effective optical components that are mechanically attached to the existing camera unit of the cell-phone. For this purpose, we used battery powered light-emitting diodes (LEDs) to pump the sample of interest from the side using butt-coupling, where the pump light was guided within the sample cuvette to uniformly excite the specimen. The fluorescent emission from the sample was then imaged using an additional lens that was positioned right in front of the existing lens of the cell-phone camera. Because the excitation occurs through guided waves that propagate perpendicular to our detection path, an inexpensive plastic colour filter was sufficient to create the dark-field background required for fluorescent imaging, without the need for a thin-film interference filter. We validate the performance of this platform by imaging various fluorescent micro-objects in 2 colours (i.e., red and green) over a large field-of-view (FOV) of ~81 mm 2 with a raw spatial resolution of ~20 μm. With additional digital processing of the captured cell-phone images, through the use of compressive sampling theory, we demonstrate ~2 fold improvement in our resolving power, achieving ~10 μm resolution without a trade-off in our FOV. Further, we also demonstrate darkfield imaging of non-fluorescent specimen using the same interface, where this time the scattered light from the objects is detected without the use of any filters. The capability of imaging a wide FOV would be exceedingly important to probe large sample volumes (e.g., >0.1 mL) of e.g., blood, urine, sputum or water, and for this end we also demonstrate fluorescent imaging of labeled white-blood cells from whole blood samples, as well as waterborne pathogenic protozoan parasites such as Giardia Lamblia cysts. Weighing only ~28 g (~1 ounce), this compact and cost-effective fluorescent imaging platform attached to a cell-phone could be quite useful especially for resource-limited settings, and might provide an important tool for wide-field imaging and quantification of various lab-on-a-chip assays developed for global health applications, such as monitoring of HIV+ patients for CD4 counts or viral load measurements.
Improving the access to effective and affordable healthcare has long been a global endeavor. In this quest, the development of cost-effective and easy-to-use medical testing equipment that enable rapid and accurate diagnosis is essential to reduce the time and costs associated with healthcare services. To this end, point-of-care (POC) diagnostics plays a crucial role in healthcare delivery in both the developed and developing countries by bringing medical testing to patients, or to sites near patients. As the diagnosis of a wide range of diseases, including various types of cancers and many endemics relies on optical techniques, numerous compact and cost-effective optical imaging platforms have been developed in recent years for use at the POC. Here, we review the state-of-the-art optical imaging techniques that can have significant impact on global health by facilitating effective and affordable POC diagnostics.
We demonstrate a compact and cost-effective imaging cytometry platform installed on a cell-phone for the measurement of the density of red and white blood cells as well as hemoglobin concentration in human blood samples. Fluorescent and bright-field images of blood samples are captured using separate optical attachments to the cell-phone and are rapidly processed through a custom-developed smart application running on the phone for counting of blood cells and determining hemoglobin density. We evaluated the performance of this cell-phone based blood analysis platform using anonymous human blood samples and achieved comparable results to a standard bench-top hematology analyser. Test results can either be stored on the cell-phone memory or be transmitted to a central server, providing remote diagnosis opportunities even in field settings.
We theoretically and experimentally analyze the biomolecule detection capability of the liquid core optical ring resonator (LCORR) as a label-free bio/chemical sensor. We first establish a simple and general linear relationship between the LCORR's bulk refractive index sensitivity (BRIS) and its response to molecule deposition onto the surface, which enables us to easily characterize the LCORR sensing performance. Then, biosensing experiments are performed with bovine serum albumin (BSA) and LCORRs of various BRISs. The experimental results are in good agreement with the theoretical prediction. Further analysis shows that the LCORR is capable of detecting BSA below 10 pM with sub-picogram/mm2 mass detection limit.
We report a cell-phone based Escherichia coli (E. coli) detection platform for screening of liquid samples. In this compact and cost-effective design attached to a cell-phone, we utilize anti-E. coli O157:H7 antibody functionalized glass capillaries as solid substrates to perform a quantum dot based sandwich assay for specific detection of E. coli O157:H7 in liquid samples. Using battery-powered inexpensive light-emitting-diodes (LEDs) we excite/pump these labelled E. coli particles captured on the capillary surface, where the emission from the quantum dots is then imaged using the cell-phone camera unit through an additional lens that is inserted between the capillary and the cell-phone. By quantifying the fluorescent light emission from each capillary tube, the concentration of E. coli in the sample is determined. We experimentally confirmed the detection limit of this cell-phone based fluorescent imaging and sensing platform as ~5 to 10 cfu mL−1 in buffer solution. We also tested the specificity of this E. coli detection platform by spiking samples with different species (e.g., Salmonella) to confirm that non-specific binding/detection is negligible. We further demonstrated the proof-of-concept of our approach in a complex food matrix, e.g., fat-free milk, where a similar detection limit of ~5 to 10 cfu mL−1 was achieved despite challenges associated with the density of proteins that exist in milk. Our results reveal the promising potential of this cell-phone enabled field-portable and cost-effective E. coli detection platform for e.g., screening of water and food samples even in resource limited environments. The presented platform can also be applicable to other pathogens of interest through the use of different antibodies.
IMPORTANCE The epidemiologic and clinical characteristics of pediatric patients with coronavirus disease 2019 (COVID-19) have been reported, but information on immune features associated with disease severity is scarce. OBJECTIVE To delineate and compare the immunologic features of mild and moderate COVID-19 in pediatric patients. DESIGN, SETTING, AND PARTICIPANTS This single-center case series included 157 pediatric patients admitted to Wuhan Children's Hospital with laboratory-confirmed severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Data were collected from January 25 to April 18, 2020. EXPOSURES Documented SARS-CoV-2 infection. MAIN OUTCOMES AND MEASURES Clinical and immunologic characteristics were collected and analyzed. Outcomes were observed until April 18, 2020. RESULTS Of the 157 pediatric patients with COVID-19, 60 (38.2%) had mild clinical type with pneumonia, 88 (56.1%) had moderate cases, 6 (3.8%) had severe cases, and 3 (1.9%) were critically ill. The 148 children with mild or moderate disease had a median (interquartile range [IQR]) age of 84 (18-123) months, and 88 (59.5%) were girls. The most common laboratory abnormalities were increased levels of alanine aminotransferase (ALT) (median [IQR], 16.0 [12.0-26.0] U/L), aspartate aminotransferase (AST) (median [IQR], 30.0 [23.0-41.8] U/L), creatine kinase MB (CK-MB) activity (median [IQR], 24.0 [18.0-34.0] U/L), and lactate dehydrogenase (LDH) (median [IQR], 243.0 [203.0-297.0] U/L), which are associated with liver and myocardial injury. Compared with mild cases, levels of inflammatory cytokines including interleukin 6, tumor necrosis factor α, and interferon γ were unchanged, whereas the level of immune suppressive interleukin 10 was markedly increased in moderate cases compared with mild cases (median [IQR], 3.96 [3.34-5.29] pg/mL vs 3.58 [3.10- 4.36] pg/mL; P = .048). There was no statistically significant difference in absolute number of lymphocytes (including T cells and B cells) between mild and moderate cases, but moderate cases were associated with a decrease in neutrophil levels compared with mild cases (median [IQR],
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.