Comminuted subcapital humerus fracture as a complication of subcutaneous implantable cardioverter-defibrillator insertion is related to an abducted and externally rotated arm position during the defibrillation threshold test at which the current pathway is through the pectoral muscle. It is advisable to adduct the arm before defibrillation threshold testing. (
Level of Difficulty: Beginner.
)
Introduction
To avoid general anesthesia (GA) and improve postoperative pain management for subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation there is a growing interest for alternative methods. We describe the first experience in the Netherlands of S-ICD implantation under Ultrasound-guided Serratus Anterior Plane Block (US-SAPB).
Methods
US-SAPB was performed 1 hour before S-ICD implantation. The two-incision technique was used and a pocket beneath the latissimus dorsi muscle was surgically created. Lidocaine was used to provide anesthesia of the skin. Sedation during defibrillation testing (DFT) was induced by intravenous Propofol. Periprocedural pain experience was monitored using the Numerical Rating Scale for Pain (NRS-Pain). The results were compared with a control group of patients undergoing S-ICD implantation under GA.
Results
Forty consecutive patients (29 Male/11 Female, median age 59 years (range 34–84 years), median body mass index 26 (range 17–41) underwent S-ICD implantation; Twenty patients under US-SAPB and twenty under GA. Median procedure time was 42 min. (range 28–60 min.) with no differences between both groups. In both groups implantations went successful and defibrillation was accomplished using 65 J. US-SAPB was successful in 19 of the 20 patients and GA was successful in all cases. Median NRS-Pain in the US-SAPB group was 2 (range 2–6) and in the GA group 4 (range 2–6). In the US-SAPB group 5 patients required additional opioids postoperatively compared to 10 patients in the GA group.
Conclusions
S-ICD implantation under US-SAPB is feasible, safe and reduces the need for postoperative opioids significantly. S-ICD implantation under US-SAPB seems a good alternative for GA.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.