This paper suggests a fast and low-cost method that can be applied in several DC/DC converter topologies for detecting open circuit faults (OCFs) and short circuit faults (SCFs). The suggested method may identify the faults of several power switches even if they occur simultaneously in multi-phase interleaved boost converters (MPh-IBC) by using just the sensors needed to control the converter. This fault detection method (FDM) is based mainly on comparing the measured inductor current and two fault detection thresholds, one for OCFs detection and the other for SCFs detection. This method combined with a corrective strategy to mitigate the negative impacts of OCFs, particularly the significant rise in the ripple of the DC bus voltage and the fuel cell (FC) current, which reduces FC aging and converter reliability. The simulation findings indicate the FDM's excellent performance and speed, as well as its usefulness in detecting defects of many power switches in the converter, with a fault detection time of up to 1.7 µs. The acquired findings further show the excellent effectiveness of the corrective strategy in reducing these ripples in the event of one or two faults.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.