The stability of a simply-supported tube subjected to annular flow in a finitelength narrow gap support is experimentally investigated. The exit boundary condition of the annular-leakage passage is known to be a possible cause of instability of the inner tube. In this study, therefore, several finite-length gap supports considering two diffuser angles were investigated on the effects of the annular gap and diffuser angle to the instability of the inner tube. Numerous experiments with the different supports have been performed in a transparent plexiglass tube so that a basic annular-flow can be provided for the inner tube and the movement of the tube can be measured by several laser vibrometers. It is observed that (1) the tube loses stability by flutter at very low flow velocity; the highest critical flow velocity is 3 m/s, (2) the critical flow velocity is strongly dependent on the annular gap size, the diffuser angle and the combination of both, and (3) generally the smaller the gap the lower the critical flow velocity.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.