Radiomics, the high-throughput mining of quantitative image features from standard-of-care medical imaging that enables data to be extracted and applied within clinical-decision support systems to improve diagnostic, prognostic, and predictive accuracy, is gaining importance in cancer research. Radiomic analysis exploits sophisticated image analysis tools and the rapid development and validation of medical imaging data that uses image-based signatures for precision diagnosis and treatment, providing a powerful tool in modern medicine. Herein, we describe the process of radiomics, its pitfalls, challenges, opportunities, and its capacity to improve clinical decision making, emphasizing the utility for patients with cancer. Currently, the field of radiomics lacks standardized evaluation of both the scientific integrity and the clinical relevance of the numerous published radiomics investigations resulting from the rapid growth of this area. Rigorous evaluation criteria and reporting guidelines need to be established in order for radiomics to mature as a discipline. Herein, we provide guidance for investigations to meet this urgent need in the field of radiomics.
In this study, we performed a systematic literature search linking radiomics to tumor biology. All but two studies (n = 39) revealed that radiomic features derived from ultrasound, CT, PET and/or MR are significantly associated with one or several specific tumor biologic substrates, from somatic mutation status to tumor histopathologic grading and metabolism. Considerable inter-observer differences were found with regard to RQS scoring, while important questions were raised concerning the interpretability of the outcome of such scores.
Historically, medical imaging has been a qualitative or semi-quantitative modality. It is difficult to quantify what can be seen in an image, and to turn it into valuable predictive outcomes. As a result of advances in both computational hardware and machine learning algorithms, computers are making great strides in obtaining quantitative information from imaging and correlating it with outcomes. Radiomics, in its two forms “handcrafted and deep,” is an emerging field that translates medical images into quantitative data to yield biological information and enable radiologic phenotypic profiling for diagnosis, theragnosis, decision support, and monitoring. Handcrafted radiomics is a multistage process in which features based on shape, pixel intensities, and texture are extracted from radiographs. Within this review, we describe the steps: starting with quantitative imaging data, how it can be extracted, how to correlate it with clinical and biological outcomes, resulting in models that can be used to make predictions, such as survival, or for detection and classification used in diagnostics. The application of deep learning, the second arm of radiomics, and its place in the radiomics workflow is discussed, along with its advantages and disadvantages. To better illustrate the technologies being used, we provide real-world clinical applications of radiomics in oncology, showcasing research on the applications of radiomics, as well as covering its limitations and its future direction.
Abstract. We present K-band commissioning observations of the Mira star prototype o Cet obtained at the ESO Very Large Telescope Interferometer (VLTI) with the VINCI instrument and two siderostats. The observations were carried out between 2001 October and December, in 2002 January and December, and in 2003 January. Rosseland angular radii are derived from the measured visibilities by fitting theoretical visibility functions obtained from center-to-limb intensity variations (CLVs) of Mira star models (Bessell et al. 1996;Hofmann et al. 1998;Tej et al. 2003b). Using the derived Rosseland angular radii and the SEDs reconstructed from available photometric and spectrophotometric data, we find effective temperatures ranging from T eff = 3192±200 K at phase Φ = 0.13 to 2918±183 K at Φ = 0.26. Comparison of these Rosseland radii, effective temperatures, and the shape of the observed visibility functions with model predictions suggests that o Cet is a fundamental mode pulsator. Furthermore, we investigated the variation of visibility function and diameter with phase. The Rosseland angular diameter of o Cet increased from 28.9 ± 0.3 mas (corresponding to a Rosseland radius of 332 ± 38 R for a distance of D = 107 ± 12 pc) at Φ = 0.13 to 34.9 ± 0.4 mas (402 ± 46 R ) at Φ = 0.4. The error of the Rosseland linear radius almost entirely results from the error of the parallax, since the error of the angular diameter is only approximately 1%.
Purpose CT ventilation imaging (CTVI) is being used to achieve functional avoidance lung cancer radiation therapy in three clinical trials (NCT02528942, NCT02308709, NCT02843568). To address the need for common CTVI validation tools, we have built the Ventilation And Medical Pulmonary Image Registration Evaluation (VAMPIRE) Dataset, and present the results of the first VAMPIRE Challenge to compare relative ventilation distributions between different CTVI algorithms and other established ventilation imaging modalities. Methods The VAMPIRE Dataset includes 50 pairs of 4DCT scans and corresponding clinical or experimental ventilation scans, referred to as reference ventilation images (RefVIs). The dataset includes 25 humans imaged with Galligas 4DPET/CT, 21 humans imaged with DTPA‐SPECT, and 4 sheep imaged with Xenon‐CT. For the VAMPIRE Challenge, 16 subjects were allocated to a training group (with RefVI provided) and 34 subjects were allocated to a validation group (with RefVI blinded). Seven research groups downloaded the Challenge dataset and uploaded CTVIs based on deformable image registration (DIR) between the 4DCT inhale/exhale phases. Participants used DIR methods broadly classified into B‐splines, Free‐form, Diffeomorphisms, or Biomechanical modeling, with CT ventilation metrics based on the DIR evaluation of volume change, Hounsfield Unit change, or various hybrid approaches. All CTVIs were evaluated against the corresponding RefVI using the voxel‐wise Spearman coefficient rS, and Dice similarity coefficients evaluated for low function lung (DSClow) and high function lung (DSChigh). Results A total of 37 unique combinations of DIR method and CT ventilation metric were either submitted by participants directly or derived from participant‐submitted DIR motion fields using the in‐house software, VESPIR. The rS and DSC results reveal a high degree of inter‐algorithm and intersubject variability among the validation subjects, with algorithm rankings changing by up to ten positions depending on the choice of evaluation metric. The algorithm with the highest overall cross‐modality correlations used a biomechanical model‐based DIR with a hybrid ventilation metric, achieving a median (range) of 0.49 (0.27–0.73) for rS, 0.52 (0.36–0.67) for DSClow, and 0.45 (0.28–0.62) for DSChigh. All other algorithms exhibited at least one negative rS value, and/or one DSC value less than 0.5. Conclusions The VAMPIRE Challenge results demonstrate that the cross‐modality correlation between CTVIs and the RefVIs varies not only with the choice of CTVI algorithm but also with the choice of RefVI modality, imaging subject, and the evaluation metric used to compare relative ventilation distributions. This variability may arise from the fact that each of the different CTVI algorithms and RefVI modalities provides a distinct physiologic measurement. Ultimately this variability, coupled with the lack of a “gold standard,” highlights the ongoing importance of further validation studies before CTVI can be widely translated from academic ce...
Quantitative radiomics features, extracted from medical images, characterize tumour-phenotypes and have been shown to provide prognostic value in predicting clinical outcomes. Stability of radiomics features extracted from apparent diffusion coefficient (ADC)-maps is essential for reliable correlation with the underlying pathology and its clinical applications. Within a multicentre, multi-vendor trial we established a method to analyse radiomics features from ADC-maps of ovarian (n = 12), lung (n = 19), and colorectal liver metastasis (n = 30) cancer patients who underwent repeated (<7 days) diffusion-weighted imaging at 1.5 T and 3 T. From these ADC-maps, 1322 features describing tumour shape, texture and intensity were retrospectively extracted and stable features were selected using the concordance correlation coefficient (CCC > 0.85). Although some features were tissue- and/or respiratory motion-specific, 122 features were stable for all tumour-entities. A large proportion of features were stable across different vendors and field strengths. By extracting stable phenotypic features, fitting-dimensionality is reduced and reliable prognostic models can be created, paving the way for clinical implementation of ADC-based radiomics.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.