Ultrasonic guided waves allow long-range screening of the full cross-section of pipelines and are thus ideal for corrosion detection. Systems using removable arrays of sensors for one-off inspections are nowadays widely-available. Guided wave pipeline monitoring, on the other hand, consists of using cheap, robust and usually permanently-mounted sensors to compare the present state of the structure with a previous or undamaged condition. Current application of available monitoring systems shows that robustness and defect detection capability remain a challenge, and some major oil and gas companies therefore consider monitoring to be less well-established. This paper deals with the design and testing of a system designed for monitoring buried and coated pipelines, focusing especially on the development of an array (or collar) of sensors. It starts by showing in detail the characterization of single piezoelectric transducers. Finite element modelling was then used to establish the dimensions of an array of these transducers, and to describe its wave-field generation characteristics. These results were then validated experimentally, initially in laboratory conditions; subsequently, a prototype was built and blind tested in near-operational conditions, which consisted of a buried full-scale pipe segment coated with Stopaq and polyethylene. The pipe segment was subjected to electrolytically accelerated corrosion at uncertain locations and at a rate which was unknown to the authors at LAMEF-UFRGS who were involved in data analysis. Results show that after 2 years of periodic data gathering, the collar showed good stability and robustness, and that it was able to detect corrosion defects found in the dissection of the pipe.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.