Bioimpedance spectroscopy (BIS) has been suggested for the assessment of fluid shifts between intracellular (ICV) and extracellular volume (ECV) during dialysis. The electrical tissue parameters are estimated by fitting a Cole-Cole model to the impedance data. Those parameters are used for the calculation of ICV and ECV with a fluid distribution model (FDM). We investigated whether postural changes cause artifacts in the volume data measured with a commercial BIS system. This is of importance at the beginning of dialysis, when the patient lies down for treatment. Volume estimations were performed during tilt table experiments with 11 healthy volunteers. Impedance spectra (5 to 500 kHz) were recorded for the total body as well as for body segments (leg and arm) during three phases: (1) 30 minutes resting in a supine position after standing; (2) 30 minutes 70 degrees head up tilt; and (3) a 30-minute resting period in a supine position. ECV and ICV were estimated with a commercially utilized FDM which is based on Hanai's mixture theory. A monoexponential function was fitted to the data for extracting the time constants and the extrapolated steady state values of the volume changes. The ECV and ICV data changed significantly during all three periods, that is, a steady state could not be reached within 30 minutes. During phase 1 the ECV decreased by 1.8 +/- 0.7%, in the tilt phase it increased by 3.8 +/- 1.1%, and in phase 3 it decreased again by 2.9 +/- 1%. The ICV increased by 3.6 +/- 2.4% during phase 1 and decreased by 6.8 +/- 5.1% during tilting; in phase 3 it increased by 4.6 +/- 1.7%. The time constants were 36.4 +/- 12.7 minutes (ECV) and 10.8 +/- 5.4 minutes (ICV) during phase 3. Segmental measurements revealed that the legs contribute significantly to the measured volume changes. The absolute volume changes in ICV and ECV differed significantly in all phases, and the same was found for the time constants during phases 1 and 3. From this discrepancy it is concluded that the measured volume changes are artifacts that are caused by extracellular fluid redistribution. Furthermore, it appears unlikely that the measured fluid shifts actually occur between ECV and ICV in the absence of osmotic changes in the body fluids. The validity of the method for a reliable assessment of volume changes during dialysis appears questionable, as dialysis-induced volume changes lie in the same range as the orthostatically-induced spurious volume changes.
OBJECTIVE: Abdominal fat is of major importance in terms of body fat distribution but is poorly re¯ected in conventional body impedance measurements. We developed a new technique for assessing the abdominal subcutaneous fat layer thickness (SFL) with single-frequency determination of the electrical impedance across the waist (SAI). SUBJECTS AND MEASUREMENTS:The method uses a tetrapolar arrangement of surface electrodes which are placed symmetrically to the umbilicus in a plane perpendicular to the body axis. Twenty-four test subjects (12 male, 12 female) underwent SAI and abdominal magnetic resonance imaging (MRI). The SFL below the sensing electrodes was determined from MRI and correlated with the SAI data at four different frequencies (5,20, 50 and 204 kHz). RESULTS: A highly signi®cant linear correlation (r 2 0.99) between SFL and SAI over a wide range of the abdominal SFL was found. Separate regression models for female and male subjects did not differ signi®cantly, except at 50 kHz. CONCLUSION: SAI represents a good predictor of the SFL and provides an excellent tool for the assessment of central obesity.
Modern pacemaker technology renders possible the adaptation of pacing rate to hemodynamic requirements. The most ambitious approach aims at restoration of the physiological closed-loop system by utilizing the information supplied by the autonomic nervous system (ANS) and extracted from myocardial contractile performance. Measurement is accomplished by the impedance method using the stimulation electrode as the measuring electrode. The ventricular inotropic parameter (VIP) has been identified as an ANS dependent parameter. A special detection algorithm, regional effective slope quantity (RQ), with high ANS sensitivity has been developed. Rate adaptation has been achieved by using an individually adjustable inotropic index (II). The concept has been evaluated in a multicenter study using a standardized exercise protocol. The results in patients with AV block demonstrate excellent agreement between spontaneous sinus rhythm and the ANS-controlled stimulation rate during different forms of exercise. Measurement of mean arterial blood pressure (MABP) supports the physiological approach of adapting the pacing rate to various types of hemodynamic challenges.
We have developed a novel model for the simulation of artefacts which are produced by stray capacitance during bioimpedance spectroscopy. We focused on whole body and segmental measurements in the frequency range 5-1000 kHz. The current source was assumed to by asymmetric with respect to ground as is the case for many commercial devices. We considered the following stray pathways: 1, cable capacitance; 2, capacitance between neighbouring electrode leads; 3. capacitance between different body segments and earth; 4, capacitance between signal ground of the device and earth. According to our results the pathways 3 and 4 cause a significant spurious dispersion in the measured impedance spectra at frequencies > 500 kHz. During segmental measurements the spectra have been found to be sensitive to an interchange of the electrode cable pairs. The sensitivity was also observed in vivo and is due to asymmetry of the potential distribution along the segment with respect to earth. In contrast to previously published approaches, our model renders possible the simulation of this effect. However, it is unable to fully explain the deviations of in vivo measured impedance spectra from a single Cole circle. We postulate that the remaining deviations are due to a physiologically caused superposition of two dispersions from two different tissues.
During dialysis the ion concentrations in many body fluids change significantly. The influence of these changes on the accuracy of volume measurements with bioimpedance spectroscopy is investigated by the following procedure: Plasma ion concentrations and impedance spectra (5-500 kHz) are measured during six standard haemodialyses. Intracellular ion concentrations are estimated using a multi-compartment model. Intra- (ICV) and extracellular (ECV) volumes are calculated using a fluid distribution model (FDM) based on Hanai's mixture theory. The input variables of the FDM are intra- and extracellular resistance data that have been fitted from impedance spectra with a Cole-Cole model. Resistivity changes (RCs) due to concentration changes of Na+, K+, Cl-, HCO3- and unspecified intracellular ions are estimated. The FDM is corrected for the RCs. Corrected ICVs and ECVs are calculated and compared with uncorrected values. The range of relative RCs between the start and end of the dialyses is -3.2% to 1.4% in the ECV and -3.7% to 1.7% in the ICV. From the RCs, volume estimation errors of -1.0% to 1.9% (ECV) and -1.2% to 2.1% (ICV) relative to the initial values have been calculated. At the end of dialysis, the percentage of the error with respect to the volume change is < 15% for the ECV but > 20% for the ICV. Consequently, a correction of the FDM for RCs is necessary to obtain more reliable ICV data.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.