Background: Intensive medical care in companion animal clinics could pose a risk for the selection and dissemination of multidrug-resistant organisms (MDROs). Infection prevention and control (IPC) concepts are key measures to reduce the spread of MDROs, but data on IPC standards in companion animal clinics is sparse. The study assessed IPC standards in seven companion animal clinics and practices in Switzerland by structured IPC audits and combined results with environmental MDRO contamination and MDRO carriage of the personnel. Methods: IPC audits were held between August 2018 and January 2019. The observations in 34 IPC areas were scored based on predefined criteria (not fulfilled/partially fulfilled/fulfilled = score 0/1/2). Environmental swabs and nasal and stool samples from veterinary personnel were tested for methicillin-resistant (MR) staphylococci and macrococci and for colistin-resistant, extended-spectrum β-lactamaseand carbapenemase-producing (CP) Enterobacterales (CPE). Species was identified by MALDI-TOF MS, antimicrobial resistance determined by microdilution and β-lactam resistance gene detection, and genetic relatedness assessed by REP−/ERIC-PCR and multilocus sequence typing.
Surgical robots have been proposed ex vivo to drill precise holes in the temporal bone for minimally invasive cochlear implantation. The main risk of the procedure is damage of the facial nerve due to mechanical interaction or due to temperature elevation during the drilling process.To evaluate the thermal risk of the drilling process, a simplified model is proposed which aims to enable an assessment of risk posed to the facial nerve for a given set of constant process parameters for different mastoid bone densities. The model uses the bone density distribution along the drilling trajectory in the mastoid bone to calculate a time dependent heat production function at the tip of the drill bit. Using a time dependent moving point source Green's function, the heat equation can be solved at a certain point in space so that the resulting temperatures can be calculated over time. The model was calibrated and initially verified with in vivo temperature data. The data was collected in minimally invasive robotic drilling of 12 holes in four different sheep. The sheep were anesthetized and the temperature elevations were measured with a thermocouple which was inserted in a previously drilled hole next to the planned drilling trajectory. Bone density distributions were extracted from pre-operative CT data by averaging Hounsfield values over the drill bit diameter. Post-operative µCT data was used to verify the drilling accuracy of the trajectories. The comparison of measured and calculated temperatures shows a very good match for both heating and cooling phases. The average prediction error of the maximum temperature was less than 0.7°C and the average root mean square error was approximately 0.5°C. To analyze potential thermal damage, the model was used to calculate temperature profiles and cumulative equivalent minutes at 43°C at a minimal distance to the facial nerve. For the selected drilling parameters, temperature elevation profiles and cumulative equivalent minutes suggest that thermal elevation of this minimally invasive cochlear implantation surgery may pose a risk to the facial nerve, especially in sclerotic or high density mastoid bones. Optimized drilling parameters need to be evaluated and the model could be used for future risk evaluation.
Hypothesis: A multielectrode probe in combination with an optimized stimulation protocol could provide sufficient sensitivity and specificity to act as an effective safety mechanism for preservation of the facial nerve in case of an unsafe drill distance during image-guided cochlear implantation. Background: A minimally invasive cochlear implantation is enabled by image-guided and robotic-assisted drilling of an access tunnel to the middle ear cavity. The approach requires the drill to pass at distances below 1 mm from the facial nerve and thus safety mechanisms for protecting this critical structure are required. Neuromonitoring is currently used to determine facial nerve proximity in mastoidectomy but lacks sensitivity and specificity necessaries to effectively distinguish the close distance ranges experienced in the minimally invasive approach, possibly because of current shunting of uninsulated stimulating drilling tools in the drill tunnel and because of nonoptimized stimulation parameters. To this end, we propose an advanced neuromonitoring approach using varying levels of stimulation parameters together with an integrated bipolar and monopolar stimulating probe. Materials and Methods: An in vivo study (sheep model) was conducted in which measurements at specifically planned and navigated lateral distances from the facial nerve were performed to determine if specific sets of stimulation parameters in combination with the proposed neuromonitoring system could reliably detect an imminent collision with the facial nerve. For the accurate positioning of the neuromonitoring probe, a dedicated robotic system for image-guided cochlear implantation was used and drilling accuracy was corrected on postoperative microcomputed tomographic images. Results: From 29 trajectories analyzed in five different subjects, a correlation between stimulus threshold and drillto-facial nerve distance was found in trajectories colliding with the facial nerve (distance <0.1 mm). The shortest pulse duration that provided the highest linear correlation between stimulation intensity and drill-to-facial nerve distance was 250 ms. Only at low stimulus intensity values ( 0.3 mA) and with the bipolar configurations of the probe did the neuromonitoring system enable sufficient lateral specificity (>95%) at distances to the facial nerve below 0.5 mm. However, reduction in stimulus threshold to 0.3 mA or lower resulted in a decrease of facial nerve distance detection range below 0.1 mm (>95% sensitivity). Subsequent histopathology follow-up of three representative cases where the neuromonitoring system could reliably detect a collision with the facial nerve (distance <0.1 mm) revealed either mild or inexistent damage to the nerve fascicles. Conclusion: Our findings suggest that although no general correlation between facial nerve distance and stimulation threshold existed, possibly because of variances in patient-specific anatomy, correlations at very close distances to the facial nerve and high levels of specificity would enable a binary respo...
The sheep is a popular animal model for human biomechanical research involving invasive surgery on the hind limb. These painful procedures can only be ethically justified with the application of adequate analgesia protocols. Regional anaesthesia as an adjunct to general anaesthesia may markedly improve well-being of these experimental animals during the postoperative period due to a higher analgesic efficacy when compared with systemic drugs, and may therefore reduce stress and consequently the severity of such studies. As a first step 14 sheep cadavers were used to establish a new technique for the peripheral blockade of the sciatic and the femoral nerves under sonographic guidance and to evaluate the success rate by determination of the colorization of both nerves after an injection of 0.5 mL of a 0.1% methylene blue solution. First, both nerves were visualized sonographically. Then, methylene blue solution was injected and subsequently the length of colorization was measured by gross anatomical dissection of the target nerves. Twenty-four sciatic nerves were identified sonographically in 12 out of 13 cadavers. In one animal, the nerve could not be ascertained unequivocally and, consequently, nerve colorization failed. Twenty femoral nerves were located by ultrasound in 10 out of 13 cadavers. In three cadavers, signs of autolysis impeded the scan. This study provides a detailed anatomical description of the localization of the sciatic and the femoral nerves and presents an effective and safe yet simple and rapid technique for performing peripheral nerve blocks with a high success rate.
An 11-year-old neutered female domestic shorthair indoor cat was presented to our hospital for treatment of a left-sided rostro-temporal basal meningioma. Focal seizures in the facial muscles had been observed sporadically for 1 year. Two weeks prior to presentation the cat had developed generalised seizures and was treated with symptomatic anticonvulsive treatment. Focal facial seizures, especially on the right side, persisted after medical therapy. From the computed tomography scan, a basal meningioma was suspected by the treating veterinarian. A left-sided suprazygomatical temporobasal approach to the zygomatic arch was chosen because it causes less soft tissue damage. After craniotomy, durotomy and gentle dorsal retraction of the left piriform lobe, the meningioma was removed. Postoperative magnetic resonance imaging confirmed complete excision of the tumour. One day after surgery the cat was alert and a left-sided facial nerve palsy was noticed. Otherwise the neurological examination was normal. Anticonvulsive and eye moistening therapy was continued for 3 months. Six months after surgery the cat was clinically normal without any recurrence of seizures.
Acute thoracolumbar disk disease leads to elevated ITP in chondrodystrophic dogs, which may contribute to increased compression of spinal cord parenchyma.
20This study aimed to characterize the nociceptive withdrawal reflex (NWR) and to define the 21 nociceptive threshold in 25 healthy, non-medicated experimental sheep in standing posture. 22Electrical stimulation of the dorsal lateral digital nerves of the right thoracic and the pelvic limb 23 was performed and surface-electromyography (EMG) from the deltoid (all animals) and the 24 femoral biceps (18 animals) or the peroneus tertius muscles (7 animals) was recorded. The 25 behavioural reaction following each stimulation was scored on a scale from 0 (no reaction) to 5 26 (strong whole body reaction). A train-of-five 1 ms constant-current pulse was used and current 27 intensity was stepwise increased until NWR threshold intensity was reached. The NWR 28 threshold intensity (I t ) was defined as the minimal stimulus intensity able to evoke a reflex with 29 a minimal Root-Mean-Square amplitude (RMS A ) of 20 µV, a minimal duration of 10 ms and a 30 minimal reaction score of 1 (slight muscle contraction of the stimulated limb) within the time 31 window 20 to 130 ms post-stimulation. Based on this value, further stimulations were 32 performed below (0.9I t ) and above threshold (1.5I t and 2I t ). The stimulus-response curve was 33 described. Data are reported as medians and interquartile ranges. 34At the deltoid muscle I t was 4.4 mA (2.9-5.7) with an RMS A of 62 µV (30-102
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.