IntroductionEndovascular treatment of stroke, although highly effective, may fail to reach complete recanalization in around 20% of cases. The Advanced Thrombectomy System (ANCD) is a novel stroke thrombectomy device designed to reduce clot fragmentation and facilitate retrieval by inducing local flow arrest and allowing distal aspiration in combination with a stent retriever. We aimed to assess the preclinical efficacy of ANCD.MethodsSoft red blood cell (RBC)-rich (n=20/group) and sticky fibrin-rich (n=30/group) clots were used to create middle cerebral artery (MCA) occlusions in two vascular phantoms. Three different treatment strategies were tested: (1) balloon guide catheter + Solitaire (BGC+SR); (2) distal access catheter + SR (DAC+SR); and (3) ANCD+SR, until complete recanalization was achieved or to a maximum of three passes. The recanalization rate was determined after each pass.ResultsAfter one pass, ANCD+SR resulted in an increased recanalization rate (94%) for all clots together compared with BGC+SR (66%; p<0.01) or DAC+SR (80%; p=0.04). After the final pass the recanalization rate increased in all three groups but remained higher with ANCD+SR (100%) than with BGC+SR (74%; p<0.01) or DAC+SR (90%; p=0.02). The mean number of passes was lower with ANCD+SR (1.06) than with BGC+SR (1.46) or DAC+SR (1.25) (p=0.01). A logistic regression model adjusted for treatment arm, clot type, and model used showed that both RBC-rich clots (OR 8.1, 95% CI 1.6 to 13.5) and ANCD+SR (OR 3.9, 95% CI 1.01 to 15.8) were independent predictors of first-pass recanalization.ConclusionIn in vitro three-dimensional models replicating MCA-M1 occlusion, ANCD+SR showed significantly better recanalization rates in fewer passes than other commonly used combinations of devices.
BackgroundANA Advanced Neurovascular Access provides a novel funnel component designed to reduce clot fragmentation and facilitate retrieval in combination with stent-retrievers (SRs) in stroke patients by restricting flow and limiting clot shaving. In previous publications ANA presented excellent in vitro/in vivo efficacy data, especially with fibrin-rich hard clots. We aimed to determine the main physical property responsible for these results, namely suction force versus aspiration flow.MethodsWe evaluated in a bench model the suction force and flow generated by ANA and compared them to other neurovascular catheters combined with a SR (Solitaire). Aspiration flow was evaluated with a flow rate sensor while applying vacuum pressure with a pump. Suction force was determined using a tensile strength testing machine and a purposely designed tool that completely seals the device tip simulating complete occlusion by a hard clot. Suction force was defined as the force needed to separate the device from the clot under aspiration. All experiments were repeated five times, and mean values used for comparisons.ResultsAspiration flow increased with the inner diameter of the device: ANA 1.85±0.04 mL/s, ACE68 3.74±0.05 mL/s, and 8F-Flowgate2 5.96±0.30 mL/s (P<0.001). After introducing the SR, the flow was reduced by an average of 0.57±0.12 mL/s. Due to its larger distal surface, ANA suction force (1.69±0.40 N) was significantly higher than ACE68 (0.26±0.04 N) and 8F-Flowgate2 (0.42±0.06 N) (P<0.001). After introducing the SR, suction force variation was not relevant except for ANA that increased to 2.64±0.41 N.ConclusionDespite lower in vitro aspiration flow, the ANA design showed a substantially higher suction force than other thrombectomy devices.
BackgroundThe Advanced Thrombectomy System (ANCD) provides a new funnel component designed to reduce clot fragmentation and facilitate retrieval in patients with stroke by locally restricting flow, allowing distal aspiration in combination with a stent retriever (SR).ObjectiveTo evaluate the preclinical efficacy and safety of the ANCD in a swine clot model.MethodsSoft and firm clots were implanted in the lingual and cervical arteries of 11 swine to obtain Thrombolysis in Cerebral Infarction (TICI) 0 blood flow. Mechanical thrombectomy was performed with either a balloon guide catheter+Solitaire 2 stent retriever (BGC+SR, n=13) or ANCD+SR (n=13). TICI flow was evaluated and successful revascularization was defined as TICI 3 (normal perfusion). To characterize safety, a total of 3 passes were performed in each vessel independent of recanalization. Tissues were explanted for histopathological analysis after 3 and 30 days, respectively.ResultsFirst pass reperfusion rates were ANCD+SR: 69% and BGC+SR: 46%. Reperfusion increased after the third pass in both groups (ANCD+SR: 100%, vs BGC+SR: 77%). Recanalization was achieved after an average of 1.4 and 1.9 passes in ANCD+SR and BGC+SR (p=0.095), respectively. Vessel injury was comparable in both groups; endothelial loss at 3 days was the most common injury seen (ANCD+SR: 1.78±1.22; BGC+SR: 2.03±1.20; p=0.73), while other histopathological markers were absent or minimal. Tissues downstream from targeted vessels also showed absence or minimal lesions across both groups.ConclusionsResults in a swine clot model support the high efficacy of the ANCD+SR without causing clinically significant vessel injury potentially related to the new funnel component.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.