Introduction Mitotane (o,p'–DDD) is the drug of choice for adrenocortical carcinomas (ACC) and its measurement in plasma is essential to control drug administration. Objective To develop and validate a simple, reliable and straightforward method for Mitotane determination in plasma samples. Method Drug free plasma samples were collected in potassium-ethylenediamine tetraacetate (K-EDTA) tubes and spiked with 1.0, 2.5, 10.0, 25.0 and 50.0 µg/mL of DDD. p,p´-DDD was used as internal standard and was added at 25.0 µg /mL to each sample, standards and controls. Samples were submitted to protein precipitation with acetonitrile and than centrifuged and 50 uL sobrenadant was injecting into a 1260 Infinity II liquid chromatography system (Agilent Technologies) and DDD and IS were detected at 230 nm by diodo array detector (DAD) in a 12 minutes isocratic mode with a solvent mixture of 60% acetonitrile and 40% formic acid in water 0.1% pump mixed, at 0.6 mL/min flow rate. Chromatography column Waters Acquity HSS T3 was kept at 28°C. We evaluated sensitivity, precision, presence of carry-over, recovery, linearity and the accuracy of this method. Results Our method resulted in a symmetrical peak shape and good baseline resolution for DDD (mitotane) and 4,4´-DDD (internal standard) with retention times of 6.0min, 6.4mim, respectively, with resolution higher than 1.5. Endogenous plasma compounds did not interfere with the evaluated peaks when blank plasma and spiked plasma with standards were compared. Linearity was assessed over the range of 1.0 to 50.0 µg/mL for DDD (R2 > 0.9987 and a 97.8% - 105.5% extraction efficiency). Analytical sensitivity was 0.98 µg/mL, functional sensitivity was 1.00 µg/mL, intra-assay and inter-assay coefficient of variation were less than 9. 98%, carry-over was not detected, recovery ranged from 98% to 117% and high accuracy was observed (89.4% to 105.9%) with no matrix effects for mitotane measurements. Patient's samples results were compared with previous measurement by GC-MS method with a high correlation (r=0.88 and bias=-10.2%) showed that our method is usefull for routine mitotane measurement. Conclusion DDD determination in plasma samples by our developed and validated method is simple, robust, efficient and sensitive for therapeutic drug monitoring and dose management in order to achieve therapeutic index of mitotane in patients with adrenocortical cancer. Presentation: Saturday, June 11, 2022 1:00 p.m. - 3:00 p.m.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.