Open fractures are at risk of serious infection and, if infected, require several surgical interventions and courses of systemic antibiotics. We investigated a new injectable formulation that simultaneously hardens in vivo to form a porous scaffold for bone repair and delivers antibiotics at high concentrations to the local site of infection. Duration of antimicrobial activity against Staphylococcus aureus was determined using the serial plate transfer test. Ultimate compressive strength and porosity of the material was measured with and without antibiotics. The material was evaluated in vivo in an ovine medial femoral condyle defect model contaminated with S. aureus. Sheep were sacrificed at either 2 or 13 weeks and the defect and surrounding bone assessed using micro-computed tomography and histology. Antimicrobial activity in vitro persisted for 19-21 days. Sheep with antibiotic-free material and bacteria became infected, while those with antibiotic-containing material and bacteria did not. Similarly, new bone growth was seen in uninoculated animals with plain polymer, and in those with antibiotic polymer with bacteria, but not in sheep with plain polymer and bacteria. The antibiotic-impregnated scaffolds were effective in preventing S. aureus infections whilst supporting bone growth and repair. If translated into clinical practice, this approach might reduce the need for systemic antibiotics.
There is a need to control the spatio-temporal release kinetics of growth factors in order to mitigate current usage of high doses. A novel delivery system, capable of providing both structural support and controlled release kinetics, has been developed from PLGA microparticles. The inclusion of a hydrophilic PLGA–PEG–PLGA triblock copolymer altered release kinetics such that they were decoupled from polymer degradation. A quasi zero order release profile over four weeks was produced using 10% w/w PLGA–PEG–PLGA with 50:50 PLGA whereas complete and sustained release was achieved over ten days using 30% w/w PLGA–PEG–PLGA with 85:15 PLGA and over four days using 30% w/w PLGA–PEG–PLGA with 50:50 PLGA. These three formulations are promising candidates for delivery of growth factors such as BMP-2, PDGF and VEGF. Release profiles were also modified by mixing microparticles of two different formulations providing another route, not previously reported, for controlling release kinetics. This system provides customisable, localised and controlled delivery with adjustable release profiles, which will improve the efficacy and safety of recombinant growth factor delivery.
Abstract:The development of growth factor delivery strategies to circumvent the burst release phenomenon prevalent in most current systems has driven research towards encapsulating molecules in resorbable polymer matrices. For these polymer release techniques to be efficacious in a clinical setting, several key points need to be addressed. This present study has investigated the encapsulation of the growth factor, BMP-2 within PLGA/PLGA-PEG-PLGA microparticles. Morphology, size distribution, encapsulation efficiency and release kinetics were investigated and we have demonstrated a sustained release of bioactive BMP-2. Furthermore, biocompatibility of the PLGA microparticles was established and released BMP-2 was shown to promote the differentiation of MC3T3-E1 cells towards the osteogenic lineage to a greater extent than osteogenic supplements (as early as day 10 in culture), as determined using alkaline phosphatase and alizarin red assays. This study showcases a potential BMP-2 delivery system which may OPEN ACCESSPolymers 2011, 3 572 now be translated into more complex delivery systems, such as 3D, mechanically robust scaffolds for bone tissue regeneration applications.
Biodegradable polymer scaffolds have great potential for regenerative medicine applications such as the repair of musculoskeletal tissues. Here, we describe the development of scaffolds that blend hydrogel components with thermoplastic materials, combining the unique properties of both components to create mouldable formulations. This study focuses on the structural and mechanical properties of the composite scaffolds, produced by combining temperature-sensitive poly(DL-lactic acid-co-glycolic acid) (PLGA)/poly(ethylene glycol) (PEG) particles with a hydrogel component [Pluronic F127, fibrin or hyaluronic acid (HyA)]. The composite formulations solidified over time at 37°C, with a significant increase (p ≤ 0.05) in compressive strength observed from 15 min to 2 h at this temperature. The maximum compressive strength was 1.2 MPa for PLGA/PEG-Pluronic F127 scaffolds, 2.4 MPa for PLGA/PEG-HyA scaffolds and 0.6 MPa for PLGA/PEG-fibrin scaffolds. Porosity for each of the PLGA/PEG-hydrogel formulations tested was between 50 and 51%. This study illustrates the ability to combine this thermoplastic PLGA/PEG system with hydrogels to fabricate composite scaffolds, and demonstrates that altering the particle to hydrogel ratio produces scaffolds with varying mechanical properties.
The EU/COLIPA in vitro phototoxicity study involved the testing of 30 chemicals in Phase II, and the ECVAM/COLIPA study on UV filter chemicals involved the testing of 20 chemicals, for which in vivo human and/or animal data were available. Primary human keratinocytes, from four separate male donors, were not found to be sensitive to the 5J/cm2 UVA produced by the SOL500 lamp when assayed by using the neutral red uptake endpoint, as employed with the 3T3 cells used in these international interlaboratory validation studies. The primary human keratinocytes tested in one laboratory alongside the 3T3 fibroblasts gave consistent indications of phototoxicity with all the phototoxicants tested in the Phase II and UV filter studies. The one exception was bithionol, which was predicted to be non-phototoxic in both studies. None of the non-phototoxic chemicals resulted in a positive reaction with the Photo-irritation Factor (PIF) version of the prediction model. However, when the Mean Photo Effect (MPE) prediction model version was applied (with a cut-off point of 0.1), one sunscreen agent, octyl salicylate, was deemed to have phototoxic potential. The entire set of negative rated chemicals included in Phase II and in the UV filter study were also rated as non-phototoxic by the MPE prediction model.
Genetic and pharmacological evidence indicates that the reduction of ataxia telangiectasia-mutated (ATM) kinase activity can ameliorate mutant huntingtin (mHTT) toxicity in cellular and animal models of Huntington’s disease (HD), suggesting that selective inhibition of ATM could provide a novel clinical intervention to treat HD. Here, we describe the development and characterization of ATM inhibitor molecules to enable in vivo proof-of-concept studies in HD animal models. Starting from previously reported ATM inhibitors, we aimed with few modifications to increase brain exposure by decreasing P-glycoprotein liability while maintaining potency and selectivity. Here, we report brain-penetrant ATM inhibitors that have robust pharmacodynamic (PD) effects consistent with ATM kinase inhibition in the mouse brain and an understandable pharmacokinetic/PD (PK/PD) relationship. Compound 17 engages ATM kinase and shows robust dose-dependent inhibition of X-ray irradiation-induced KAP1 phosphorylation in the mouse brain. Furthermore, compound 17 protects against mHTT (Q73)-induced cytotoxicity in a cortical-striatal cell model of HD.
A range of cosmetics formulations with human patch-test data were supplied in a coded form, for the examination of the use of a combined in vitro permeability barrier assay and cell viability assay to generate, and then test, a prediction model for assessing potential human skin patch-test results. The target cells employed were of the Madin Darby canine kidney cell line, which establish tight junctions and adherens junctions able to restrict the permeability of sodium fluorescein across the barrier of the confluent cell layer. The prediction model for interpretation of the in vitro assay results included initial effects and the recovery profile over 72 hours. A set of the hand-wash, surfactant-based formulations were tested to generate the prediction model, and then six others were evaluated. The model system was then also evaluated with powder laundry detergents and hand moisturisers: their effects were predicted by the in vitro test system. The model was under-predictive for two of the ten hand-wash products. It was over-predictive for the moisturisers, (two out of six) and eight out of ten laundry powders. However, the in vivo human patch test data were variable, and 19 of the 26 predictions were correct or within 0.5 on the 0–4.0 scale used for the in vivo scores, i.e. within the same variable range reported for the repeat-test hand-wash in vivo data.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.