Background An infraacetabular screw path facilitates the closure of a periacetabular fixation frame to increase the plate fixation strength in acetabular fractures up to 50%. Knowledge of the variance in corridor sizes and axes has substantial surgical relevance for safe screw placement. Questions/purposes (1) What proportion of healthy pelvis specimens have an infraacetabular corridor that is 5 mm or larger in diameter? (2) Does a universal corridor axis and specific screw entry point exist? (3) Are there sex-specific differences in the infraacetabular corridor size or axis and are these correlated with anthropometric parameters like age, body weight and height, or the acetabular diameter? Methods A template pelvis with a mean shape from 523 segmented pelvis specimens was generated using a CTbased advanced image analyzing system. Each individual pelvis was registered to the template using a free-form registration algorithm. Feasible surface regions for the entry and exit points of the infraacetabular corridor were marked on the template and automatically mapped to the individual samples to perform a measurement of the maximum sizes and axes of the infraacetabular corridor on each specimen. A minimum corridor diameter of at least 5 mm was defined as a cutoff for placing a 3.5-mm cortical screw in clinical settings. Results In 484 of 523 pelves (93%), an infraacetabular corridor with a diameter of at least 5 mm was found. Using the mean axis angulations (54.8°[95% confidence interval {CI}, 0.6] from anterocranial to posterocaudal in relation to the anterior pelvic plane and 1.5°[95% CI, 0.4] from anteromedial to posterolateral in relation to the sagittal midline plane), a sufficient osseous corridor was present in 64% of pelves. Allowing adjustment of the three-dimensional axis by another 5°included an additional 25% of pelves. All corridor parameters were different between females and males (corridor diameter, 6.9 [95% CI, 0
Background Percutaneous iliosacral screw placement is the standard procedure for fixation of posterior pelvic ring lesions, although a transsacral screw path is being used more frequently in recent years owing to increased fracture-fixation strength and better ability to fix central and bilateral sacral fractures. However, biomorphometric data for the osseous corridors are limited. Because placement of these screws in a safe and effective manner is crucial to using transsacral screws, we sought to address precise sacral anatomy in more detail to look for anatomic variation in the general population. Questions/purposes We asked: (1) What proportion of healthy pelvis specimens have no transsacral corridor at the level of the S1 vertebra owing to sacral dysmorphism? (2) If there is no safe diameter for screw placement in the transsacral S1 corridor, is an increased and thus safe diameter of the transsacral S2 corridor expected? (3) Are there sex-specific differences in sacral anatomy and are these correlated with known anthropometric parameters? Methods CT scans of pelves of 280 healthy patients acquired exclusively for medical indications such as polytrauma (20%), CT angiography (70%), and other reasons (10%), were segmented manually. Using an advanced CT-based image analysis system, the mean shape of all segmented pelves was generated and functioned as a template. On this template, the cylindric transsacral osseous corridor at the level of the S1 and S2 vertebrae was determined manually. Each pelvis then was registered to the template using a free-form registration algorithm to measure the maximum screw corridor diameters on each specimen semiautomatically. Results Thirty of 280 pelves (11%) had no transsacral S1 corridor owing to sacral dysmorphism. The average of maximum cylindrical diameters of the S1 corridor for the remaining 250 pelves was 12.8 mm (95% CI, 12.1-13.5 mm). A transverse corridor for S2 was found in 279 of 280 pelves, with an average of maximum cylindrical diameter of 11.6 mm (95% CI, 11.3-11.9 mm). Decreasing
For a variety of medical applications, detailed knowledge on the statistical distribution of morphometric characteristics among specific patient groups is required. We present a novel approach for performing automated morphometric measurements on the surface of anatomical bone samples obtained from CT segmentation. The system developed supports various types of measurements (distances, angles, radii) on several kinds of features (points, lines, planes or circles), which are performed automatically for every bone sample in a given data set. The desired features can be specified by the user in two ways, either by marking them on a standardized template that is mapped to all samples via a correspondence mapping, or by hierarchically building new features from existing features. The system was implemented and tested on a database containing about 1200 segmented femur. The quality of the automated matching was assessed through a study comparing the performance of the system with results obtained from manual labeling by medical experts. It was found that the deviation between the two methods was generally less than 2mm.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.