Purpose Noninvasive prenatal testing (NIPT) is a highly sensitive and specific method for detection of fetal chromosomal aneuploidies from maternal plasma. The objective of this study was to determine the performance of a new paired-end sequencing-based NIPT assay in 13,607 pregnancies from a single center in Germany. Methods Samples from 13,607 pregnant women who previously underwent NIPT were analyzed using VeriSeq NIPT Solution v2 assay for presence of common fetal trisomies and monosomy X. Follow-up to determine clinical truth was carried out. Results Of the 13,607 cases, 13,509 received a NIPT call resulting in a low study failure rate of 0.72%. There were 188 (1.4%) high-risk calls: 117 trisomy 21, 34 trisomy 18, 23 trisomy 13, one trisomy 21 + 13, and 13 monosomy X. High sensitivities and specificities of ≥ 98.89% were reported for all four aneuploidy conditions. Of the high-risk cases, clinical follow-up data were available for 77.1% (145/188). Clinical follow-up of high-risk calls revealed an overall positive predictive value of 84.8% (potential range 65.4–88.3%). NIPT results were provided for samples across a range of fetal fractions, down to 2% fetal fraction. Conclusion The VeriSeq NIPT Solution v2 assay detected fetal chromosomal aneuploidies across a range of fetal fractions with high sensitivities and specificities observed based on known clinical outcomes, a high overall PPV, and a low failure rate.
Background & Patient: Data from 3?008 patients, who underwent single-nucleotide-polymorphism (SNP)-based noninvasive prenatal testing (NIPT) are presented. Method: The PanoramaTM test (Natera, San Carlos, CA) was used to analyze cell-free fetal DNA from maternal blood for trisomies 21, 18, and 13, triploidy and sex-chromosome aneuploidies. Result: In 2?942 (97.8%) cases, a result was obtained. The average fetal fraction was 10.2%. A high-risk result for fetal aneuploidy was made for 65 (2.2%) cases. In 59 (90.8%) of these cases, invasive testing confirmed the aneuploidy. There were 6 false-positive cases. In the false-positive group, the fetal fraction was significantly lower. The overall positive predictive value was 90.8%. No false-negative cases were reported but many patients in this study have not delivered yet. Therefore, exact data cannot be given for potential false-negative cases. Conclusion: SNP-based NIPT is a reliable screening method for evaluating the risk of aneuploidies of chromosomes 21, 18 and 13. By using NIPT, the number of invasive procedures may be reduced significantly compared to maternal age and first-trimester screening.
Analysis of 545 NIPT high-risk cases with high risk for trisomy 21 (T21), 18 (T18), and 13 (T13), as well as monosomy X (MX) from routine NIPT testing in a single prenatal center in Germany. Analysis was performed using the VeriSeq NIPT Solution v2 (Illumina Inc., USA). The assessment of true vs false positive results were based on clinical outcome data.The average fetal fraction of 9.7% was within the expected range in T21 and MX but lower in T18 and T13. For all high-risk groups sensitivity and specificity was far above 99%. The positive predictive value (PPV) was highest at trisomy 21 with 94.1%, followed by trisomy 18 with 80.9%. For trisomy 13 and Monosomy X, the PPV was clearly lower at 60.5% and 65.6%, respectively. PPV was dependent on different indications and maternal age.We could show that statistical tools of the method like the log likelihood ratio (LLR) score and T-Statistics value are important to distinguish between (clinical) false positive and true positive NIPT results in trisomies. The relationship between results and quality scores is less significant for MX cases.The study shows that the Illumina VeriSeq v2 procedure is a highly reliable NIPT method with a low no call rate in the hands of experienced diagnostic laboratories.
In this study we wanted to determine the performance of a paired-end sequencing-based noninvasive prenatal testing (NIPT) assay in the detection of common fetal trisomies in twin pregnancy samples. Samples from patients with a twin pregnancy were collected from at least 10 weeks of gestation and analyzed at a single prenatal center in Germany. Results of Anomaly Detected (i.e., high risk) or No Anomaly Detected (i.e., low risk) for trisomy 21, trisomy 18, or trisomy 13 were reported. Follow-up confirmatory outcomes were requested for all cases. A total of 1,658 patients with twin pregnancies submitted samples during the study period; only two of these samples failed resulting in a low failure rate of 0.12%. Of the remaining 1,656 cases, there were 1,625 (98.1%) low-risk and 31 (1.9%) high-risk NIPT samples in our cohort. Of these, follow-up information was available for 301 (18.5%) of the low-risk samples and 19 (61.3%) of the high-risk samples. All of the low-risk cases with follow-up were determined to be true negatives giving an estimated negative predictive value of 100%. Seventeen of the 19 high-risk samples with follow-up were true positives, resulting in an overall positive predictive value of 89.5%. Sensitivities of > 99.9% were noted for both trisomy 21 and trisomy 18, with high specificities of ≥ 99.7% observed for all three trisomies. In conclusion, our study showed strong performance of the NIPT assay in the detection of common fetal trisomies in twin pregnancy samples, with high sensitivities, specificities, and positive predictive values observed based on known clinical outcomes along with a low failure rate.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.