Despite their significant impact on public health, antibiotic resistance and size distributions of airborne viable bacteria in indoor environments in neonatal intensive care units (NICU) remain understudied. Therefore, the objective of this study was to assess the antibiotic resistance of airborne viable bacteria for different sizes (0.65–7 µm) in private-style and public-style neonatal intensive care units (NICU). Airborne bacteria concentrations were assessed by a six-stage Andersen impactor, operating at 28.3 L/min. Public-style NICU revealed higher concentrations of airborne viable bacteria (53.00 to 214.37 CFU/m3) than private-style NICU (151.94–466.43), indicating a possible threat to health. In the public-style NICU, Staphylococcus was the highest bacterial genera identified in the present study, were Staphylococcus saprophyticus and Staphylococcus epidermidis predominated, especially in the second bronchi and alveoli size ranges. Alloiococcus otitidis, Bacillus subtiles, Bacillus thuringiensis, Kocuria rosea, and Pseudomonas pseudoalcaligene, were identified in the alveoli size range. In NICU#2, eight species were identified in the alveoli size range: Bacillus cereus, Bacillus subtilis, Bacillus thuringiensis, Eikenella corrodens, Pseudomonas aeruginosa, Staphylococcus aureus, Staphylococcus epidermidis, and Streptococcus gordoni. Multi-drug-resistant organisms (MDROs) were found in both of the NICUs. Bacillus cereus strains were resistant to Ampicillin, Cefoxitin, Ceftaroline, and Penicillin G. Staphylococcus cohnii ssp. cohnii was resistant in parallel to ampicillin and G penicillin. Staphylococcus saprophyticus strains were resistant to Ampicillin, Penicillin G, Oxaxilin, and Erythromycin. Results may indicate a potential threat to human health due to the airborne bacteria concentration and their antibiotic resistance ability. The results may provide evidence for the need of interventions to reduce indoor airborne particle concentrations and their transfer to premature infants with underdeveloped immune systems, even though protocols for visitors and cleaning are well-established.
The object of this research to determine the statistical relationship and degree of association between variables: hospital admission days and diagnostic (disease) potentially associated to fungal bioaerosols exposure. Admissions included acute respiratory infections, atopic dermatitis, pharyngitis and otitis. Statistical analysis was done using Statgraphics Centurion XVI software. In addition, was estimated the occupational exposure to fungal aerosols in stages of a landfill using BIOGAVAL method and represented by Golden Surfer XVI program. Biological risk assessment with sentinel microorganism A. fumigatus and Penicillium sp, indicated that occupational exposure to fungal aerosols is Biological action level. Preventive measures should be taken to reduce the risk of acquiring acute respiratory infections, dermatitis or other skin infections.
The object of this research was to obtain the Crude Enzymatic Extract (CEE) of Yarrowia lipolytica ATCC 9773, in the medium of 30% Water of Sales (SW) applying a biologically treatment to three different concentrations yeast inoculum food wastewater, collected from cheese and whey production. It was evaluated the behavior of the inoculum in a suitable medium that stimulates lipids biodegradation. The standard liquid-liquid partition method SM 5520 B was used to quantify fat and oil removal for each concentration of yeast, before treatment and post treatment. The Industrial Fat effluent was characterized by physical chemical patterns, and two treatments were evaluated; Treatment 1 consisted of pH 5.0 and treatment 2 with a pH of 6.5, both with the following characteristics; Concentration of inoculum 8% 12% and 16% at 27Â °C temperature and evaluation time 32Â h. The best results (2.702Â mg/L fat and 83% degradation oil) were found to be pH 5.0, 16% concentration and 27Â °C, BOD5, and COD decreased by 43.07% and 44.35%, respectively during the 32Â h; For pH 6.5, 8% concentration at 32Â h and at room temperature, degraded 2.177Â mg/L fat and oil (67% degradation); The BOD5, and COD decreased by 37.93% and 39.19%, in the same time span. The treatment at pH 5.0 inoculum concentration of 16% was effective in removing 83% of the volume of fats and oil in the effluent, representing a useful tool for the wastewater treatment.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.