3-D surgical planning for restorative osteotomy is costly and time-consuming because surgeons need to be helped from commercial companies to get 3-D printed bones. However, practitioners can save time and keep the cost to a minimum by utilizing free software and establishing their 3-D printers locally. Surgical planning for the corrective osteotomy of antebrachial growth deformities (AGD) is challenging for several reasons (the nature of the biapical or multiapical conformational abnormalities and lack of a reference value for the specific breed). Pre-operative planning challenges include: a definite description of the position of the center of rotation of angulation (CORA) and proper positioning of the osteotomies applicable to the CORA. In the present study, we demonstrated an accurate and reproducible bone-cutting technique using patient-specific instrumentations (PSI) 3-D technology. The results of the location precision showed that, by using PSIs, the surgeons were able to accurately replicate preoperative resection planning. PSI results also indicate that PSI technology provides a smaller standard deviation than the freehand method. PSI technology performed in the distal radial angular deformity may provide good cutting accuracy. In conclusion, the PSI technology may improve bone-cutting accuracy during corrective osteotomy by providing clinically acceptable margins.
Lipopolysaccharides (LPS) cause systemic inflammatory responses, which are characterized by high mortality and multiple signs, including metabolic disturbances, respiratory acidosis, hypotension, and vital organs disorder. Cytokines secretion and oxidative stress are the main features of the disease. Diagnosis and treatment of systemic inflammation (SI) remain a challenge. Korean Red Ginseng (RG) is one of medicinal herbs that showed a potent anti-oxidant effect. We aimed to study the protective effects of RG on systemic inflammatory response in rats and RAW 264.7 macrophage cells induced by LPS. The rats were treated with water and alcohol extracts of RG for four weeks to prevent the inflammatory response. The result showed that LPS toxin increased morbidity and mortality, and induced liver, kidney, and lung injuries manifested by deteriorated biomarkers. Hypotension, hypomagnesemia, acidosis, and oxidative stress were observed in septic rats. However, RG extracts attenuated liver, kidney, and lung enzymes and metabolites in treated groups via its anti-inflammatory and anti-oxidant properties. Furthermore, RG improved magnesium and blood pressure in the treated groups. RAW 264.7 macrophage cells exposed to LPS disturbance in translocation of p65 and MAPK/p38. Nevertheless, RG-pretreated cells did not significantly alter. In conclusion, RG reduced the rates of mortality and morbidity of treated rats — liver, kidney, and lung injuries were protected in the treated groups through the potentiation of anti-oxidant defense. RG was able to conserve mitochondrial function, inhibiting the activation of MAPK/p38 signaling and suppressing NF-[Formula: see text]B p65 cytoplasm-nucleus transport. Further studies are needed to examine the effects on chronic conditions in animal models and human.
One of the most frequent bone deformities in dogs is antebrachial growth deformity (AGD), which results from malunion of the distal growth plates. The objective of the present study was to re-align the limbs, which can correct the length mismatch and reset the coherence of the joint with the aid of a 3-D phantom model for surgical preplanning. A 14-month-old, intact female Golden Retriever with an angular deformity of the left radius and ulna was selected for the study. The diagnosis was confirmed by orthogonal radiographs. Moreover, computed tomography (CT) scans revealed a multiplane deformity with valgus, procurator, and external rotation of the left radius. The pre-surgical planning started with the quantification of the angular deformity, followed by a simulated virtual osteotomy, and concluded with an in vitro rehearsal surgery on 3-D printed phantom bone models. In the operating room, prefabricated patient-specific instrumentation (PSI) was attached at the planned site of the radial bone surface for a precise closing wedge osteotomy. Then two locking plates were fixed routinely. Post-operative radiographs showed accurate correction of the deformity as we had planned. At 12 weeks post-operatively, the follow-up surveys revealed improved gait, weight-bearing, and progression of bone healing. Our PSI design, based on novel surgical planning, was steady yet straightforward during the osteotomy. The osteotomy was performed without difficulty since the PSI that pre-determined the sites and angles let the surgeon perform the antebrachial malformation surgery. This method of operation reduces stress on the operator and helps to improve accuracy, repeatability, and surgery time.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.