This is a proposal and description of a new configuration for an Offner imaging spectrometer based on the theory of aberrations of off-plane classical-ruled spherical diffraction gratings. This new spectrometer comprises a concave mirror used in double reflection and a convex reflection grating operating in quadrature, in a concentric layout. A very simple procedure obtains designs that are anastigmatic for a given point on the entrance slit and a given wavelength. Specific examples show that the performance of this type of system improves the performance of analogous conventional in-plane systems, when compactness and/or high spectral resolution is of fundamental importance.
In this paper, the imaging performance of an Offner concentric imaging spectrometer is analyzed when the spectrometer entrance slit is disposed arbitrarily on the plane that is parallel to the grating grooves and contains the common center of curvature. Astigmatism-corrected designs are obtained for off-plane incidence on the grating if one point on the slit is located on the Rowland circle of the primary mirror. In this case, the combined system of primary mirror plus diffraction grating provides two astigmatic line images oriented parallel and orthogonal to the plane of diffraction, with the former located on the same plane as the slit. Consequently, these images can be brought to a single focus on this plane by the tertiary mirror if its radius of curvature is chosen properly. In addition, coma aberration is simultaneously removed. These results can be applied to the design of two-mirror or three-mirror spectrometers, generalizing the concept of the best imaging circle and providing solutions to get anastigmatic imaging for two object points and two wavelengths.
Abstract:The availability and performance of laser-based adaptive optics (AO) systems are strongly dependent on the power and quality of the laser beam before being projected to the sky. Frequent and time-consuming alignment procedures are usually required in the laser systems with free-space optics to optimize the beam. Despite these procedures, significant distortions of the laser beam have been observed during the first two years of operation of the Gemini South multi-conjugate adaptive optics system (GeMS). A beam shaping concept with two deformable mirrors is investigated in order to provide automated optimization of the laser quality for astronomical AO. This study aims at demonstrating the correction of quasi-static aberrations of the laser, in both amplitude and phase, testing a prototype of this two-deformable mirror concept on GeMS. The paper presents the results of the preparatory study before the experimental phase. An algorithm to control amplitude and phase correction, based on phase retrieval techniques, is presented with a novel unwrapping method. Its performance is assessed via numerical simulations, using aberrations measured at GeMS as reference. The results predict effective amplitude and phase correction of the laser distortions with about 120 actuators per mirror and a separation of 1.4 m between the mirrors. The spot size is estimated to be reduced by up to 15% thanks to the correction. In terms of AO noise level, this has the same benefit as increasing the photon flux by 40%.
We review the theory of spherical diffraction gratings with regard to their imaging properties in off-plane arrangements. Our study is restricted to gratings with equally spaced grooves, and it is focused on the quadrature configuration, where the incident and diffraction planes are orthogonal to each other. We identify regions of low astigmatism and propose some monochromator mounts.
The light path function (LPF) of an Offner spectrometer is presented. The evaluation of the LPF of this spectrometer enables its imaging properties to be studied for arbitrary object and image positions, while avoiding the more complicated analysis of intermediate images generated by the diffraction grating, which is often involved. A power series expansion of the LPF on the grating coordinates directly determines pupil aberrations of the generated spectrum and facilitates the search for configurations with small low-order aberrations. This analysis not only confirms the possibility of reducing low-order aberrations in Rowland-type mounts, namely astigmatism and coma, as predicted in previous studies, but also proves that all third-order terms in the series expansion of the aberration function can be canceled at the image of the design point and for the corresponding design wavelength, when the design point is located on a plane orthogonal to the optical axis. Furthermore, fourth-order terms are computed and shown to represent the most relevant contribution to image blurring. Third- and fourth-order aberrations are also evaluated for Rowland mounts with the design point located outside the aforementioned plane. The study described in this manuscript is not restricted to small angles of incidence, and, therefore, it goes beyond Seidel and Buchdahl aberrations.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.