Background
We present a complex case of a failing tricuspid mechanical valve prosthesis in a patient with refractory cardiogenic shock at prohibitive risk for surgery in whom balloon ‘valvuloplasty’ resulted in immediate haemodynamic improvement in valve function.
Case summary
A 67-year-old woman with remote history of endocarditis s/p tricuspid valve repair and mechanical aortic valve replacement was referred for second opinion and management of new severe symptomatic tricuspid valve stenosis resulting in progressive debilitating congestive heart failure (HF). The patient was approved by the heart team to undergo redo open heart for surgical repair of the tricuspid valve. Intraoperative technical challenges were met to repair the tricuspid valve. In turn, the native valve was resected and a 33 mm On-X mechanical valve prosthesis. The patient’s post-operative course was complicated by recurrent haemoptysis, prolonged mechanical respiratory support, acute kidney injury, and cardiogenic shock. Surgical re-exploration to address the dysfunctional mechanical tricuspid valve was felt to be prohibitive. Structural heart team was consulted. Cardiac catheterization was recommended to ascertain and confirm findings. The patient was transferred to the cardiac catheterization laboratory. Initial fluoroscopic examination of the heart confirmed the echocardiographic results of an immobile septal leaflet of the recently implanted mechanical tricuspid valve. An 8 × 40 mm Mustang OTW angioplasty balloon was then advanced across the mechanical valve and inflated gradually at nominal pressure. A single inflation resulted in successful restoration of valve leaflet function.
Discussion
To the best of our knowledge, this is the first balloon ‘valvuloplasty’ on a mechanical On-X valve in the tricuspid position.
Mitral paravalvular leak (PVL) remains a well-known complication after mitral valve replacement. Since the first report over 25 years ago, several catheter-based PVL closure techniques have been described. Most of these comprise of either an antegrade transseptal approach, or a retrograde transaortic or transapical approach. We herein report a novel percutaneous mitral PVL closure technique that was safely and successfully performed after failed attempt using a conventional antegrade approach.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.