Background: The Carpentier-Edwards Perimount valves have a proven track record in aortic valve replacement: good durability, hemodynamic performance, rates of survival, and low rates of valve-related complications and prosthesis-patient mismatch. The St. Jude Medical Trifecta is a newer valve that has shown comparable early and midterm outcomes. Studies show reoperation rates of Trifecta are comparable with Perimount valves, with a few recent studies bringing into focus early structural valve deterioration (SVD), and increased midterm SVD in younger patients. Given that midterm data for Trifecta is still sparse, we wanted to confirm the early low reoperation rates of Trifecta persist over time compared with Perimount. Methods: The Maritime Heart Centre Database was searched for AVR between 2011 and 2016, inclusive. The primary endpoint of the study was all-cause reoperation rate. Results: In total, 711 Perimount and 453 Trifecta implantations were included. The reoperation hazards were determined for age: 0.96 (0.92-0.99; p = .02), female (vs. male): 0.35 (0.08-1.53; p = .16), smoker (vs. nonsmoker): 2.44 (0.85-7.02; p = .1), and Trifecta (vs. Perimount): 2.68 (0.97-7.39; p = .06). Kaplan-Meier survival analysis in subgroups-age <60, age ≥60, male, female, smoker, and nonsmokershowed Perimount having lower reoperation rates than Trifecta in patients younger than 60 (p = .02) and current smokers (p < .01). Conclusions: The rates of reoperation of Perimount and Trifecta were comparable, with Trifecta showing higher rates in patients younger than 60 years, and current smokers. Continued diligence and further independent reporting of midterm reoperation and SVD rates of the Trifecta, including detailed echocardiographic follow-up, are needed to confirm these findings.
Atrial septal defect (ASD) with drainage of the inferior vena cava (IVC) into the left atrium (LA) is a rare congenital anomaly. Few cases have been reported in the literature. We present a 17-year-old female with an ASD and an anomalous drainage of the IVC into the LA leading to cyanosis since early childhood. Diagnosis was documented by computed tomography (CT) angiography and confirmed intra-operatively. The patient underwent successful surgical correction with an uneventful postoperative course.
Background
Patient‐prosthesis mismatch (PPM) has been identified as a risk factor for mortality and reoperation in patients undergoing surgical aortic valve replacement (SAVR). We present a retrospective analysis of risk factors for PPM and the effects of PPM on early postoperative outcomes after SAVR.
Methods
Chart review was conducted for patients (N = 3003) undergoing SAVR. PPM was calculated from valve reference orifice areas and patient body surface area. Logistic regression was used to analyze risk factors for PPM and develop a risk score from these results. Regression was also conducted to identify associations between projected PPM status and postoperative outcomes.
Results
Risk factors for PPM included female sex, higher body mass index (BMI), and use of the St. Jude Epic valve. Patients receiving St. Jude trifecta valves or mechanical valves were less likely to have predicted PPM. We developed a risk score using BMI, sex, and valve type, and retrospectively predicted PPM in our cohort. Mild PPM (odds ratio [OR] = 2.267), severe PPM (OR = 2.869), male sex (OR = 2.091), and younger age (OR = 0.940) were all predictors of SAVR reoperation, while aortic root replacement was associated with reduced reoperation rates (OR = 0.122). Severe PPM carried a risk of in‐hospital mortality (OR = 3.599), and moderate PPM carried a smaller but significant risk (OR = 1.920). Other factors increasing postoperative morbidity and mortality included older age, renal failure, and diabetes.
Conclusion
PPM could be retrospectively predicted in our cohort using a risk calculation from sex, BMI and valve type. We conclude that all degrees of PPM carry risk for mortality and reoperation.
Cor triatriatum is a rare congenital cardiac anomaly that usually becomes symptomatic in the first years of life. We present a 28-year-old pregnant female patient presented with shortness of breath, palpitations and decreased exercise tolerance. Transthoracic (TTE) and transesophageal (TEE) echocardiography showed cor triatriatum, features of severe mitral stenosis and atrial septal defect (ASD). The patient underwent successful surgical correction with an uneventful postoperative course.
Spontaneous bleeding from liver is a possible complication after open heart surgery. We submit the case for the academic interest and to discuss the possible cause of hemorrhage.
Pyoderma gangrenosum (PG) can mimic early postoperative sternal wound infections. Steroid therapy is the only method of treatment for this condition, which recognizes the fact that steroids can lead to immunosuppression and potentially inhibit healing after major surgery.
Background
Aortic valve replacement (AVR) is one of the most common open‐heart surgical procedures. The durability of the tissue valve in the aortic position is crucial in AVR and transcatheter AVR. We reviewed structural valve deterioration using echocardiographic follow‐up in three types of surgical aortic tissue valves.
Methods
A retrospective analysis was conducted where hemodynamic deterioration was evaluated and compared using transthoracic echocardiography, including pressure gradients and effective orifice area. Kaplan–Meier analyses were used to summarize the time to failure.
Results
The study included 133 Trifecta, 156 Epic, and 321 Magna Ease valves. Seventy‐six percent (1941/2551) of patients had to be excluded due to insufficient echo data. Through univariate analysis, 34% (216/610) of valves met deterioration criteria after 24 months. Unadjusted survival curves showed a significant difference between valves (p ≤ .001), with a longer mean time to deterioration for the Magna Ease versus Trifecta and Epic of 68.9 versus 50.1 and 38.2 months, respectively. A Cox proportional hazard analysis found worse hazard ratios of 1.69 (p ≤ .04) and 2.4 (p ≤ .01) for Trifecta versus Magna and Epic versus Trifecta, respectively.
Conclusion
All three valve types demonstrated structural valve deterioration on echocardiographic follow‐up with significant differences in rate. The Magna Ease appeared to have the highest durability, and the Epic the lowest. Further investigation is warranted to confirm the results in a larger multicenter study.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.