A new concept in intraoperative decision support for tumour delineation is proposed showing that artificial intelligence provides categorising information and interpretation from the images captured during fluorescence-guided colorectal cancer operations. This is potentially applicable to all cancer subtypes and is pertinent to new fluorophore development.A new concept in intraoperative decision support for tumour delineation is proposed showing that artificial intelligence provides categorising information and interpretation from the images captured during fluorescence-guided colorectal cancer operations. This is potentially applicable to all cancer subtypes and is pertinent to new fluorophore development. A new concept in intraoperative decision support for tumour delineation is proposed showing that artificial intelligence provides categorising information and interpretation from the images captured during fluorescence-guided colorectal cancer operations. This is potentially applicable to all cancer subtypes and is pertinent to new fluorophore development.
Shows promise
Despite of some beneficial effect of epidural analgesia on return of bowel function and pain in laparoscopic surgery, it does not affect LOS, which is multifactorial.
BackgroundThere is currently conflicting evidence surrounding the effects of obesity on postoperative outcomes. Previous studies have found obesity to be associated with adverse events, but others have found no association. The aim of this study was to determine whether increasing body mass index (BMI) is an independent risk factor for development of major postoperative complications.MethodsThis was a multicentre prospective cohort study across the UK and Republic of Ireland. Consecutive patients undergoing elective or emergency gastrointestinal surgery over a 4‐month interval (October–December 2014) were eligible for inclusion. The primary outcome was the 30‐day major complication rate (Clavien–Dindo grade III–V). BMI was grouped according to the World Health Organization classification. Multilevel logistic regression models were used to adjust for patient, operative and hospital‐level effects, creating odds ratios (ORs) and 95 per cent confidence intervals (c.i.).ResultsOf 7965 patients, 2545 (32·0 per cent) were of normal weight, 2673 (33·6 per cent) were overweight and 2747 (34·5 per cent) were obese. Overall, 4925 (61·8 per cent) underwent elective and 3038 (38·1 per cent) emergency operations. The 30‐day major complication rate was 11·4 per cent (908 of 7965). In adjusted models, a significant interaction was found between BMI and diagnosis, with an association seen between BMI and major complications for patients with malignancy (overweight: OR 1·59, 95 per cent c.i. 1·12 to 2·29, P = 0·008; obese: OR 1·91, 1·31 to 2·83, P = 0·002; compared with normal weight) but not benign disease (overweight: OR 0·89, 0·71 to 1·12, P = 0·329; obese: OR 0·84, 0·66 to 1·06, P = 0·147).ConclusionOverweight and obese patients undergoing surgery for gastrointestinal malignancy are at increased risk of major postoperative complications compared with those of normal weight.
As indocyanine green (ICG) with near-infrared (NIR) endoscopy enhances real-time intraoperative tissue microperfusion appreciation, it may also dynamically reveal neoplasia distinctively from normal tissue especially with video software fluorescence analysis. Colorectal tumours of patients were imaged mucosally following ICG administration (0.25 mg/kg i.v.) using an endo-laparoscopic NIR system (PINPOINT Endoscopic Fluorescence System, Stryker) including immediate, continuous in situ visualization of rectal lesions transanally for up to 20 min. Spot and dynamic temporal fluorescence intensities (FI) were quantified using ImageJ (including videos at one frame/second, fps) and by a bespoke MATLAB® application that provided digitalized video tracking and signal logging at 30fps (Fluorescence Tracker App downloadable via MATLAB® file exchange). Statistical analysis of FI-time plots compared tumours (benign and malignant) against control during FI curve rise, peak and decline from apex. Early kinetic FI signal measurement delineated discriminative temporal signatures from tumours (n = 20, 9 cancers) offering rich data for analysis versus delayed spot measurement (n = 10 cancers). Malignant lesion dynamic curves peaked significantly later with a shallower gradient than normal tissue while benign lesions showed significantly greater and faster intensity drop from apex versus cancer. Automated tracker quantification efficiently expanded manual results and provided algorithmic KNN clustering. Photobleaching appeared clinically irrelevant. Analysis of a continuous stream of intraoperatively acquired early ICG fluorescence data can act as an in situ tumour-identifier with greater detail than later snapshot observation alone. Software quantification of such kinetic signatures may distinguish invasive from non-invasive neoplasia with potential for real-time in silico diagnosis.
Right-sided colonic (cecal) tumors rarely present with features of acute appendicitis. Only those patients with atypical presentation and findings should have pre-operative radiological evaluation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.