This relatively simple methodology provides a scientific and systematic approach, which can be used in the region to estimate population sizes, understand geographical distribution of these groups and recognize the various operational typologies and dynamics of these populations for developing effective prevention strategies.
Introduction. Transfusion Transmitted Infections (TTIs) continue to be a major risk in transfusions in many parts of the world. The transfusion-dependent β-thalassaemia patients are particularly at risk of acquiring TTIs. The current study was undertaken to estimate the prevalence of TTIs in transfusion-dependent β-thalassaemia patients. Material and Methods. A cross-sectional study of 1253 multitransfused thalassaemia major patients was conducted in five different centres of Islamabad, Rawalpindi, and Karachi. The study subjects were screened for HIV, HCV, and HBV. The screening was performed at two centres: Department of Pathology, Shaheed Zulfiqar Ali Bhutto (SZAB) Medical University, and Blood Transfusion Services, Jinnah Postgraduate Medical Centre, from July to December 2015. The confirmatory screening was performed by Chemiluminescent Immunoassay (CLIA). Results. Out of the 1253 multiple transfused patients, 317 (25.3%) were infected with TTIs. HCV was positive in 273 cases (21.7%), HBV in 38 cases (3.0%), and HIV in 6 cases (0.5%). Conclusion. HCV was the leading TTI in multitransfused thalassaemia major patients in the study. Presence of HIV in thalassaemia patients is a recent disturbing development in Pakistan. Improved regulation of blood banks including use of internationally or nationally evaluated kits will bring down the incidence of TTIs in transfusion-dependent β-thalassaemia patients. More stringent behavioral and serological pretransfusion screening of blood for TTIs must be implemented in blood banks.
Objective: To determine the prevalence of Hepatitis-B, Hepatitis-C and Human Immunodeficiency infections in replacement blood donors.Materials and Methods: From January 2004 to December 2011, 108,598 apparently healthy donors donated blood at our Blood Bank. Screening was done by Microparticle Enzyme Immuno Assay (MEIA) method on Axsym System (Abbott Diagnostic, USA) and in year 2011 by Chemiluminescent Immunoassay (CIA) method on Architect i2000 (Abbott Diagnostic, USA). From 2010 onward, HIV reactive donors were advised for confirmatory tests and reported back with the results.Results: Of the 108,598 total donors, 108,393 (99.8%) were replacement donors with a mean age of 28.92 (17-55) years. Of this, only 164 (0.15%) were females. Among the replacement donors, 4,906 (4.5%) were found to be reactive for Hepatitis-B, C and Human Immunodeficiency Virus. All the reactive patients, except one, were males. HbsAg was positive in 2,068 (1.90%) and anti-HCV in 2832 (2.61%) donors, while 111 (0.10%) were positive for Human Immunodeficiency Virus. Co-infectivity was observed in 103 (0.09%) cases. The prevalence appeared to be higher in younger age group (17-30 yrs). Only 16.6% cases should be patients returned with results of the confirmatory tests for HIV and were found positive.Conclusion: Hepatitis-B and C sero-prevalence in our series of replacement donors appears high compared to most studies from neighboring countries and relatively low in comparison to earlier studies from Pakistan. Prevalence of HIV, however, appears low and turn out of HIV positive cases for confirmatory tests is low.Conflict of interest:None declared.
BackgroundInfection with the Hepatitis B virus (HBV) continues to be one of the leading healthcare issues in Pakistan, affecting over 6 million people. The existence of HBsAg mutants is well documented in many countries. In Pakistan, HBV screening in the majority of the blood banks is performed by Rapid Detection Devices or ELISA tests. These tests are designed to detect HBsAg, but may not detect the mutant HBsAg. Failure to detect the HBsAg mutant may result in the transmission of HBV infection from donor to recipient. Hence, there is a need to identify a HBsAg assay which can detect mutants in a country where simple and conventional HBsAg assays with varying sensitivity and specificity are used to detect HBV infections.Material and methodsThree routinely used diagnostic tests (Rapid Detection Devices, ELISA and CLIA) for HBsAg were compared with the LIAISON® XL Murex HBsAg Quant Assay to determine the prevalence of HBV mutants in the Pakistani blood donor population.The samples of blood donors from different cities of Pakistan were collected. The testing was performed using SD Bioline rapid assay (n = 1500), ELISA (n = 1500), and Abbott ARCHITECT®CLIA system (n = 1500) at the centers where the donations were collected. All samples (n = 4500) were re-tested for comparative analysis on the LIAISON® XL Murex HBsAg Quant assay (DiaSorin S.p.A.). PCR testing was performed as a gold standard on all discordant samples.Results119/4500 (2.64%) of the samples were positive for antibodies against HBsAg. The sensitivity of SD Bioline Rapid, GB HBsAg ELISA, Abbott ARCHITECT® and LIAISON® XL Murex HBsAg Quant assay was 17.24%, 43.75%, 90.91%and 100% respectively. The specificity of SD Bioline Rapid, GB HBsAg ELISA, Abbott ARCHITECT® and LIAISON® XL Murex HBsAg Quant Assay was 98.82%, 99.59%, 100% and 100%, respectively.ConclusionLIAISON® XL Murex HBsAg Quant assay is a highly sensitive, specific and accurate screening assay for detecting wild type as well as mutant HBsAg.
The big picture An overview of the HIV epidemic and response in Asia and the Pacific Asia and the Pacific's AIDS response is showing mixed results. ■ Despite important progress, such as a 26% reduction in new HIV infections since 2001 and significantly increased domestic financing for AIDS, the epidemic still outpaces the response and half of people eligible for antiretroviral treatment are not accessing it. ■ There are growing epidemics in some geographical areas and within key populations at higher risk, notably among men who have sex with men, in many countries. ■ Not enough people from key populations at higher risk know their HIV status. This is hampering increased access to treatment. ■ Domestic financing for HIV has increased considerably in the region but HIV expenditure remains insufficient and international funding is shrinking. An estimated 3-4 million people living in Asia inject drugs. In three countries with expanding epidemics-Indonesia, Pakistan and the Philippines-injecting drug use has been a significant factor in the spread of HIV. In 2012, HIV prevalence among people who inject drugs was 36.4% in Indonesia, 27.2% in Pakistan and 13.6% in the Philippines. 5 National trends sometimes mask significant geographical variations in HIV prevalence among injecting drug users. In the Philippine province of Cebu, prevalence among people who inject drugs was estimated at 53.8% in 2011 compared with 13.6% nationally. 6 In the province of Thai Nguyen in Viet Nam, the prevalence among this group was reported to be 38.8% in 2012, compared with national prevalence of 11.6%. 7 There has been progress in reducing new HIV infections among female sex workers across the region. National prevalence has declined in the early Fewer new HIV infections overall, but instances of rising trends Total people living with HIV in 12 countries 4 734 000
INTRODUCTION:Internal quality control (IQC) is the backbone of quality assurance program. In blood banking, the quality control of blood products ensures the timely availability of a blood component of high quality with maximum efficacy and minimal risk to potential recipients. The main objective of this study is to analyze the IQC of blood products as an indicator of our blood bank performance.METHODS:An observational cross-sectional study was conducted at the blood bank of Liaquat National Hospital and Medical College, from January 2014 to December 2015. A total of 100 units of each blood components were arbitrarily chosen during the study. Packed red cell units were evaluated for hematocrit (HCT); random platelet concentrates were evaluated for pH, yield, and culture; fresh frozen plasma (FFP) and cryoprecipitate (CP) were evaluated for unit volume, factor VIII, and fibrinogen concentrations.RESULTS:A total of 400 units were tested for IQC. The mean HCT of packed red cells was 69.5 ± 7.24, and in 98% units, it met the standard (<80% of HCT). The mean platelet yield was 8.8 ± 3.40 × 109/L and pH was ≥6.2 in 98% bags; cultures were negative in 97% of units tested. Mean factor VIII and fibrinogen levels were found to be 84.24 ± 15.01 and 247.17 ± 49.69 for FFP, respectively. For CP, mean factor VIII and fibrinogen level were found to be 178.75 ± 86.30 and 420.7 ± 75.32, respectively.CONCLUSION:The IQC of blood products at our blood bank is in overall compliance and met recommended international standards. Implementation of standard operating procedures, accomplishment of standard guidelines, proper documentation with regular audit, and staff competencies can improve the quality performance of the transfusion services.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.