The turn-to-turn contact resistance (characteristic resistance) is a very important factor to a no-insulation (NI) (RE)Ba2Cu3Oy (REBCO) pancake coil. It characterizes the stability and charging delay of NI REBCO pancake coils. However, the ordinary sudden-discharging method cannot measure the turn-to-turn contact resistance under different conditions, such as an operating current, a temperature, and an external magnetic field. Although the turn-to-turn contact condition is strongly affected by the pressure inside of the NI REBCO coils, the feature of the contact resistance must be clarified to estimate the stability of NI REBCO coils.In this paper, we have proposed a new method to measure the turn-to-turn contact resistance applying AC current. The theory and the measurement results are also shown. The measured turn-to-turn contact resistance is reasonable, compared with that measured by the ordinary sudden-discharging method. In near future, we will measure the turn-to-turn contact resistance under different conditions by means of the proposed method.Index Terms-No-insulation winding technique, REBCO pancake coil, turn-to-turn contact resistance measurement.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.