The principles, development, and recent application of electrospray ionization-mass spectrometry (ESI-MS) to biological compounds are reviewed. ESI-MS methods now allow determination of accurate molecular weights for proteins extending to over 50,000, and in some cases well over 100,000. Similar capabilities are being developed for oligonucleotides. The instrumentation used for ESI-MS is briefly described and it is shown that, although ionization efficiency appears to be uniformly high, detector sensitivity may be directly correlated with molecular weight. The use of tandem mass spectrometry (e.g., MS/MS) for extending collision-induced dissociation (CID) methods to the structural studies of large molecules is described. For example, effective CID of various albumin species (molecular weight approximately 66,000) can be obtained, far larger than obtainable for singly charged molecular ions. The combination of capillary electrophoresis, in both free solution zone electrophoresis and isotachophoresis formats, as well as microcolumn liquid chromatography with ESI-MS, provides the capability for on-line separation and analysis of subpicomole quantities of proteins. These and other new developments related to ESI-MS are illustrated by a range of examples. Fundamental considerations suggest even more impressive developments may be anticipated related to detection sensitivity and methods for obtaining structural information.
We describe and demonstrate a global strategy that extends the sensitivity, dynamic range, comprehensiveness, and throughput of proteomic measurements based upon the use of peptide "accurate mass tags" (AMTs) produced by global protein enzymatic digestion. The two-stage strategy exploits Fourier transform-ion cyclotron resonance (FT-ICR) mass spectrometry to validate peptide AMTs for a specific organism, tissue or cell type from "potential mass tags" identified using conventional tandem mass spectrometry (MS/MS) methods, providing greater confidence in identifications as well as the basis for subsequent measurements without the need for MS/MS, and thus with greater sensitivity and increased throughput. A single high resolution capillary liquid chromatography separation combined with high sensitivity, high resolution and accurate FT-ICR measurements has been shown capable of characterizing peptide mixtures of significantly more than 10(5) components with mass accuracies of < 1 ppm, sufficient for broad protein identification using AMTs. Other attractions of the approach include the broad and relatively unbiased proteome coverage, the capability for exploiting stable isotope labeling methods to realize high precision for relative protein abundance measurements, and the projected potential for study of mammalian proteomes when combined with additional sample fractionation. Using this strategy, in our first application we have been able to identify AMTs for >60% of the potentially expressed proteins in the organism Deinococcus radiodurans.
Understanding biological systems and the roles of their constituents is facilitated by the ability to make quantitative, sensitive, and comprehensive measurements of how their proteome changes, e.g., in response to environmental perturbations. To this end, we have developed a high-throughput methodology to characterize an organism's dynamic proteome based on the combination of global enzymatic digestion, high-resolution liquid chromatographic separations, and analysis by Fourier transform ion cyclotron resonance mass spectrometry. The peptides produced serve as accurate mass tags for the proteins and have been used to identify with high confidence >61% of the predicted proteome for the ionizing radiation-resistant bacterium Deinococcus radiodurans. This fraction represents the broadest proteome coverage for any organism to date and includes 715 proteins previously annotated as either hypothetical or conserved hypothetical.
The development of a new ion mobility/mass spectrometry instrument that incorporates a multifield drift tube/ion funnel design is described. In this instrument, individual components from a mixture of ions can be resolved and selected on the basis of mobility differences prior to collisional activation inside the drift tube. The fragment ions that are produced can be dispersed again in a second ion mobility spectrometry (IMS) region prior to additional collisional activation and MS analysis. The result is an IMS-IMS analogue of MS-MS. Here, we describe the preliminary instrumental design and experimental approach. We illustrate the approach by examining the highly characterized bradykinin and ubiquitin systems. Mobility-resolved fragment ions of bradykinin show that b-type ions are readily discernible fragments, because they exist as two easily resolvable structural types. Current limitations and future directions are briefly discussed.
Electrospray-ionization (ESI) mass spectrometry is used to monitor higher order structural changes of polypeptides induced by alteration of the pH or organic solvent composition in the protein solution environment. A bimodal charge-state distribution is observed in the ESI mass spectrum of ubiquitin (relative molecular mass 8565) in solutions containing small amounts (less than 20%) of organic solvents. The distribution of peaks at high m/z (low-charge state) is found to represent the protein in its native, globular state; the higher-charge-state distribution is characteristic for a more extended conformation. Addition of methanol denaturant in excess of 40% v/v is needed to eliminate the low-charge-state distribution completely. Lesser amounts of acetonitrile, acetone, or isopropanol (approximately 20%) are required to denature the ubiquitin protein. Other proteins showing conformational effects in their ESI mass spectra are also illustrated. While the ESI spectra are related to solution phase structure, ESI-tandem mass spectrometry of multiply charged molecular ions of different conformation is suggested as a probe of gas-phase protein three-dimensional structure.
In this study, high-efficiency packed capillary reversed-phase liquid chromatography (RPLC) coupled on-line with high-performance Fourier transform ion cyclotron resonance (FTICR) mass spectrometry has been investigated for the characterization of complex cellular proteolytic digests. Long capillary columns (80-cm) packed with small (3-micron) C18 bonded particles provided a total peak capacity of approximately 1000 for cellular proteolytic polypeptides when interfaced with an ESI-FTICR mass spectrometer under composition gradient conditions at a pressure of 10,000 psi. Large quantities of cellular proteolytic digests (e.g., 500 micrograms) could be loaded onto packed capillaries of 150-micron inner diameter without a significant loss of separation efficiency. Precolumns with suitable inner diameters were found useful for improving the elution reproducibility without a significant loss of separation quality. Porous particle packed capillaries were found to provide better results than those containing nonporous particles because of their higher sample capacity. Two-dimensional analyses from the combination of packed capillary RPLC with high-resolution FTICR yield a combined capacity for separations of > 1 million polypeptide components and simultaneously provided information for the identification of the separated components based upon the accurate mass tag concept previously described.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.