Pacing threshold is affected by many factors. A pacing system able to confirm capture at each beat and automatically adjust its output close to the actual pacing threshold is highly desirable. This study evaluates the safety and efficacy of the Autocapture function of the Pacesetter Microny SR+. One hundred thirteen patients were recruited from 16 centers in 7 European countries and followed up for 1 year. All pacemakers were implanted with Pacesetter's low polarization, bipolar leads. The key feature of Autocapture is the immediate delivery of a 4.5 V safety backup pulse 62.5 ms after any ineffective ongoing low output pulse. Holter recordings confirmed total reliability of this feature without any exit block. The measured evoked response (ER) signal was stable over time. Acute and chronic pacing thresholds measured by VARIO and Autocapture tests correlated (r > 0.79) over the period of the study. The incidence of backup pulses was 1.1% during pacing. With Autocapture programmed ON, the overall total current consumption was 4.1 microA for VVI and 5.0 microA for VVIR pacing. This study proved that the Autocapture safely and reliably regulates the pacemaker's output according to the prevailing threshold thus providing maximum patient safety and prolonging service life.
BackgroundIf conservative treatment for chronic plantar fasciitis fails, often a corticosteroid injection is given. Corticosteroid injection gives temporarily pain reduction, but no healing. Blood platelets initiate the natural healing rate. GPS® gives an eightfold concentrate platelets of patients own blood. Injection of these platelets in the attachment of the fascia to the os calcis might induce a healing rate.Methods and designA randomized controlled multi centre trial will be performed. The study population consists of 120 patients of 18 years and older. Patients with chronic plantar fasciitis will be allocated randomly to have a steroid injection or an autologous platelet concentrate injections. Data will be collected before the procedure, 4,8,12,26 weeks and 1 year after the procedure.The main outcome measures of this study are pain and function measured with questionnaires.ConclusionRecent literature show positive effects for the treatment of tendinosis with autologous platelet injections. The forthcoming trial will compare treatment for chronic plantar fasciitis with a steroid injection versus an autologous platelet injection. Our results will be published as soon as they become available.Trial RegistrationTrial registration number: http://www.clinicaltrials.gov NCT00758641.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.