Large-eddy simulations (LES) with the newThis is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. R. Heinze et al.at building confidence in the model's ability to simulate small-to mesoscale variability in turbulence, clouds and precipitation. The results are encouraging: the high-resolution model matches the observed variability much better at small-to mesoscales than the coarser resolved reference model. In its highest grid resolution, the simulated turbulence profiles are realistic and column water vapour matches the observed temporal variability at short time-scales. Despite being somewhat too large and too frequent, small cumulus clouds are well represented in comparison with satellite data, as is the shape of the cloud size spectrum. Variability of cloud water matches the satellite observations much better in ICON than in the reference model. In this sense, it is concluded that the model is fit for the purpose of using its output for parametrization development, despite the potential to improve further some important aspects of processes that are also parametrized in the high-resolution model.
A new technique for interactive vector field visualization using large numbers of properly illuminated field lines is presented. Taking into account ambient, diffuse, and specular reflection terms as well as transparency and depth cueing, we employ a realistic shading model which significantly increases quality and realism of the resulting images. While many graphics workstations offer hardware support for illuminating surface primitives, usually no means for an accurate shading of line primitives are provided. However, we show that proper illumination of lines can be implemented by exploiting the texture mapping capabilities of modern graphics hardware. In this way high rendering performance with interactive frame rates can be achieved. We apply the technique to render large numbers of integral curves of a vector field. The impression of the resulting images can be further improved by a number of visual enhancements, like transparency and depthcueing. We also describe methods for controlling the distribution of field lines in space. These methods enable us to use illuminated field lines for interactive exploration of vector fields.
Time-efficient and easy-to-use segmentation algorithms (contour generation) are a precondition for various applications in radiation oncology, especially for planning purposes in hyperthermia. We have developed the three following algorithms for contour generation and implemented them in an editor of the HyperPlan hyperthermia planning system. Firstly, a manual contour input with numerous correction and editing options. Secondly, a volume growing algorithm with adjustable threshold range and minimal region size. Thirdly, a watershed transformation in two and three dimensions. In addition, the region input function of the Helax commercial radiation therapy planning system was available for comparison. All four approaches were applied under routine conditions to two-dimensional computed tomographic slices of the superior thoracic aperture, mid-chest, upper abdomen, mid-abdomen, pelvis and thigh; they were also applied to a 3D CT sequence of 72 slices using the three-dimensional extension of the algorithms. Time to generate the contours and their quality with respect to a reference model were determined. Manual input for a complete patient model required approximately 5 to 6 h for 72 CT slices (4.5 min/slice). If slight irregularities at object boundaries are accepted, this time can be reduced to 3.5 min/slice using the volume growing algorithm. However, generating a tetrahedron mesh from such a contour sequence for hyperthermia planning (the basis for finite-element algorithms) requires a significant amount of postediting. With the watershed algorithm extended to three dimensions, processing time can be further reduced to 3 min/slice while achieving satisfactory contour quality. Therefore, this method is currently regarded as offering some potential for efficient automated model generation in hyperthermia. In summary, the 3D volume growing algorithm and watershed transformation are both suitable for segmentation of even low-contrast objects. However, they are not always superior to user-friendly manual programs for contour generation. When the volume growing algorithm is used, the contours have to be postprocessed with suitable filters. The watershed transformation has a large potential if appropriately developed to 3D sequences and 3D interaction features. After all, the practicality and feasibility of every segmentation method critically depend on various details of the user software as pointed out in this article.
Flow visualization of a near wall flow is of great importance in the field of biofluid mechanics in general and for studies of pathologic vessel enlargements (aneurysms) particularly. Wall shear stress (WSS) is one of the important hemodynamic parameters implicated in aneurysm growth and rupture. The WSS distributions in anatomically realistic vessel models are normally investigated by computational fluid dynamics (CFD). However, the results of CFD flow studies should be validated. The recently proposed Wall-PIV method was first applied in an enlarged transparent model of a cerebri anterior artery terminal aneurysm made of silicon rubber. This new method, called Wall-PIV, allows the investigation of a flow adjacent to transparent surfaces with two finite radii of curvature (vaulted walls). Using an optical method which allows the observation of particles up to a predefined depth enables the visualization solely of the boundary layer flow. This is accomplished by adding a specific molecular dye to the fluid which absorbs the monochromatic light used to illuminate the region of observation. The results of the Wall-PIV flow visualization were qualitatively compared with the results of the CFD flow simulation under steady flow conditions. The CFD study was performed using the program FLUENT®. The results of the CFD simulation were visualized using the line integral convolution (LIC) method with a visualization tool from AMIRA®. The comparison found a very good agreement between experimental and numerical results.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.