Deep vein thrombosis (DVT) of the lower extremities can be associated with significant morbidity and may progress to pulmonary embolism and postthrombotic syndrome. Early diagnosis and treatment are important to minimize the risk of these complications. We systematically reviewed the accuracy of diagnostic tests for first-episode and recurrent DVT of the lower extremities, including proximal compression ultrasonography (US), whole leg US, serial US, and high-sensitivity quantitative D-dimer assays. We searched Cochrane Central, MEDLINE, and EMBASE for eligible studies, reference lists of relevant reviews, registered trials, and relevant conference proceedings. Two investigators screened and abstracted data. Risk of bias was assessed using Quality Assessment of Diagnostic Accuracy Studies-2 and certainty of evidence using the Grading of Recommendations Assessment, Development and Evaluation framework. We pooled estimates of sensitivity and specificity. The review included 43 studies. For any suspected DVT, the pooled estimates for sensitivity and specificity of proximal compression US were 90.1% (95% confidence interval [CI], 86.5-92.8) and 98.5% (95% CI, 97.6-99.1), respectively. For whole-leg US, pooled estimates were 94.0% (95% CI, 91.3-95.9) and 97.3% (95% CI, 94.8-98.6); for serial US pooled estimates were 97.9% (95% CI, 96.0-98.9) and 99.8% (95% CI, 99.3-99.9). For D-dimer, pooled estimates were 96.1% (95% CI, 92.6-98.0) and 35.7% (95% CI, 29.5-42.4). Recurrent DVT studies were not pooled. Certainty of evidence varied from low to high. This systematic review of current diagnostic tests for DVT of the lower extremities provides accuracy estimates. The tests are evaluated when performed in a stand-alone fashion, and in a diagnostic pathway. The pretest probability of DVT often assessed by a clinical decision rule will influence how, together with sensitivity and specificity estimates, patients will be managed.
Pulmonary embolism (PE) is a common, potentially life-threatening yet treatable condition. Prompt diagnosis and expeditious therapeutic intervention is of paramount importance for optimal patient management. Our objective was to systematically review the accuracy of D-dimer assay, compression ultrasonography (CUS), computed tomography pulmonary angiography (CTPA), and ventilation-perfusion (V/Q) scanning for the diagnosis of suspected first and recurrent PE. We searched Cochrane Central, MEDLINE, and EMBASE for eligible studies, reference lists of relevant reviews, registered trials, and relevant conference proceedings. 2 investigators screened and abstracted data. Risk of bias was assessed using Quality Assessment of Diagnostic Accuracy Studies-2 and certainty of evidence using the Grading of Recommendations Assessment, Development and Evaluation framework. We pooled estimates of sensitivity and specificity. The review included 61 studies. The pooled estimates for D-dimer sensitivity and specificity were 0.97 (95% confidence interval [CI], 0.96-0.98) and 0.41 (95% CI, 0.36-0.46) respectively, whereas CTPA sensitivity and specificity were 0.94 (95% CI, 0.89-0.97) and 0.98 (95% CI, 0.97-0.99), respectively, and CUS sensitivity and specificity were 0.49 (95% CI, 0.31-0.66) and 0.96 (95% CI, 0.95-0.98), respectively. Three variations of pooled estimates for sensitivity and specificity of V/Q scan were carried out, based on interpretation of test results. D-dimer had the highest sensitivity when compared with imaging. CTPA and V/Q scans (high probability scan as a positive and low/non-diagnostic/normal scan as negative) both had the highest specificity. This systematic review was registered on PROSPERO as CRD42018084669.
Von Willebrand disease, (VWD) disproportionately affects women due to potential issues with heavy menstrual bleeding (HMB), delivery complications, and postpartum hemorrhage (PPH). To systematically synthesize the evidence regarding first line management of HMB, treatment of women requiring/desiring neuraxial analgesia, and management of PPH. We searched Medline and EMBASE through October 2019 for randomized trials, comparative observational studies, and case series comparing the effects of desmopressin, hormonal therapy, and tranexamic acid (TXA) on HMB, comparing different von Willebrand factor (VWF) levels in women with VWD undergoing labor and receiving neuraxial anesthesia and the effects of TXA on PPH We conducted duplicate study selection, data abstraction, and appraisal of risk of bias. Whenever possible, we conducted meta-analyses. We assessed the quality of the evidence using the GRADE approach. We included 1 randomized trial, 3 comparative observational studies and 10 case series. Moderate certainty evidence showed that desmopressin results in a smaller reduction of menstrual blood loss (difference in mean change from baseline, 41.6 [95% CI, 16.6 to 63.6] points in pictorial blood assessment chart score as compared to TXA. There was very low certainty evidence about how first line treatments compare against each other, the effects of different VWF levels in women receiving neuraxial anesthesia, and the effects of TXA administration postpartum. Most of the evidence relevant to the gynecologic and obstetric management of women with VWD addressed by most guidelines is very low quality. Future studies addressing research priorities will be key when updating such guidelines.
The long-term overall survival of Ewing sarcoma (EWS) patients remains poor; less than 30% of patients with metastatic or recurrent disease survive despite aggressive combinations of chemotherapy, radiation and surgery. To identify new therapeutic options, we employed a multi-pronged approach using in silico predictions of drug activity via an integrated bioinformatics approach in parallel with an in vitro screen of FDA-approved drugs. Twenty-seven drugs and forty-six drugs were identified, respectively, to have anti-proliferative effects for EWS, including several classes of drugs in both screening approaches. Among these drugs, 30 were extensively validated as mono-therapeutic agents and 9 in 14 various combinations in vitro. Two drugs, auranofin, a thioredoxin reductase inhibitor, and ganetespib, an HSP90 inhibitor, were predicted to have anti-cancer activities in silico and were confirmed active across a panel of genetically diverse EWS cells. When given in combination, the survival rate in vivo was superior compared to auranofin or ganetespib alone. Importantly, extensive formulations, dose tolerance, and pharmacokinetics studies demonstrated that auranofin requires alternative delivery routes to achieve therapeutically effective levels of the gold compound. These combined screening approaches provide a rapid means to identify new treatment options for patients with a rare and often-fatal disease.
Upper extremity deep vein thrombosis (UEDVT) accounts for ≤10% of DVT and can be associated with morbidity and mortality. Accurate diagnosis and treatment are necessary for safe and effective patient management. We systematically reviewed the accuracy of D-dimer and duplex ultrasonography (US) for the evaluation of suspected first-episode UEDVT. We searched the Cochrane Central Register, OVID MEDLINE, EMBASE, and PubMed for eligible studies, reference lists of relevant reviews, registered trials, and relevant conference proceedings. We included prospective cross-sectional and cohort studies that evaluated test accuracy. Two investigators independently screened and collected data. The risk of bias was assessed using Quality Assessment of Diagnostic Accuracy Studies 2 and certainty of evidence using the Grading of Recommendations Assessment, Development and Evaluation framework. We pooled estimates of sensitivity and specificity. The review included 9 studies. The pooled estimates for D-dimer sensitivity and specificity were 0.96 (95% confidence interval [CI], 0.87-0.99) and 0.47 (95% CI, 0.43-0.52), respectively. The pooled estimates for duplex US sensitivity and specificity were 0.87 (95% CI, 0.73-0.94) and 0.85 (95% CI, 0.72-0.93), respectively. Certainty of evidence was moderate. In this review, we summarized the test accuracy (sensitivity and specificity) of D-dimer and duplex US for this indication. The sensitivity and specificity of the tests found in the present review should be considered in the context of whether they are used alone or in combination, which is dependent on the prevalence of disease in the population, the clinical setting in which the patient is being evaluated, cost, potential harms, and patient outcomes. This study was registered at PROSPERO as Systematic Review Registration Number CRD42018098488.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.