Major advances in delivery systems in recent years have turned radiotherapy (RT) into a more effective way to manage prostate cancer. Still, adjacency of organs at risk (OARs) can severely limit RT benefits. Rectal spacer implant in recto-prostatic space provides sufficient separation between prostate and rectum, and therefore, the opportunity for potential dose escalation to the target and reduction of OAR dose. Pretreatment simulation of spacer placement can potentially provide decision support to reduce the risks and increase the efficacy of the spacer placement procedure. Methods: A novel finite element method-oriented spacer simulation algorithm, FEMOSSA, was developed in this study. We used the finite element (FE) method to model and predict the deformation of rectum and prostate wall, stemming from hydrogel injection. Ten cases of prostate cancer, which undergone hydrogel placement before the RT treatment, were included in this study. We used the pre-injection organ contours to create the FE model and post-injection spacer location to estimate the distribution of the virtual spacer. Material properties and boundary conditions specific to each patient's anatomy were assigned. The FE analysis was then performed to determine the displacement vectors of regions of interest (ROIs), and the results were validated by comparing the virtually simulated contours with the real post-injection contours. To evaluate the different aspects of our method's performance, we used three different figures of merit: dice similarity coefficient (DSC), nearest neighbor distance (NND), and overlapped volume histogram (OVH). Finally, to demonstrate a potential dosimetric application of FEMOSSA, the predicted rectal dose after virtual spacer placement was compared against the predicted post-injection rectal dose. Results: Our simulation showed a realistic deformation of ROIs. The post-simulation (virtual spacer) created the same separation between prostate and rectal wall, as post-injection spacer. The average DSCs for prostate and rectum were 0.87 and 0.74, respectively. Moreover, there was a statistically significant increase in rectal contour similarity coefficient (P < 0.01). Histogram of NNDs showed the same overall shape and a noticeable shift from lower to higher values for both post-simulation and post-injection, indicative of the increase in distance between prostate and rectum. There was less than 2.2-and 2.1-mm averaged difference between the mean and fifth percentile NNDs. The difference between the OVH distances and the corresponding predicted rectal dose was, on average, less than 1 mm and 1.5 Gy, respectively. Conclusions: FEMOSSA provides a realistic simulation of the hydrogel injection process that can facilitate spacer placement planning and reduce the associated uncertainties. Consequently, it increases the robustness and success rate of spacer placement procedure that in turn improves prostate cancer RT quality.
We investigate two margin-based schemes for optimization target volumes (OTV), both isotropic expansion (2 mm) and beam-specific OTV, to account for uncertainties due to the setup errors and range uncertainties in pancreatic stereotactic pencil beam scanning (PBS) proton therapy. Also, as 2-mm being one of the extreme sizes of margin, we also study whether the plan quality of 2mm uniform expansion could be comparable to other plan schemes. Methods and Materials: We developed 2 schemes for OTV: (1) a uniform expansion of 2 mm (OTV 2mm ) for setup uncertainty and (2) a water equivalent thickness−based, beam-specific expansion (OTV WET ) on beam direction and 2 mm expansion laterally. Six LAPC patients were planned with a prescribed dose of 33 Gy (RBE) in 5 fractions. Robustness optimization (RO) plans on gross tumor volumes, with setup uncertainties of 2 mm and range uncertainties of 3.5%, were implemented as a benchmark. Results: All 3 optimization schemes achieved decent target coverage with no significant difference. The OTV 2mm plans show superior organ at risk (OAR) sparing, especially for proximal duodenum. However, OTV 2mm plans demonstrate severe susceptibility to range and setup uncertainties with a passing rate of 19% of the plans meeting the goal of 95% volume covered by the prescribed dose. The proposed dose spread function analysis shows no significant difference. Conclusions: The use of OTV WET mimics a union volume for all scenarios in robust optimization but saves optimization time noticeably. The beam-specific margin can be attractive to online adaptive stereotactic body proton therapy owing to the efficiency of the plan optimization.
PurposeWe proposed a Haar feature-based method for tracking endoscopic ultrasound (EUS) probe in diagnostic computed tomography (CT) and Magnetic Resonance Imaging (MRI) scans for guiding hydrogel injection without external tracking hardware. This study aimed to assess the feasibility of implementing our method with phantom and patient images.Materials and MethodsOur methods included the pre-simulation section and Haar features extraction steps. Firstly, the simulated EUS set was generated based on anatomic information of interpolated CT/MRI images. Secondly, the efficient Haar features were extracted from simulated EUS images to create a Haar feature dictionary. The relative EUS probe position was estimated by searching the best matched Haar feature vector of the dictionary with Haar feature vector of target EUS images. The utilization of this method was validated using EUS phantom and patient CT/MRI images.ResultsIn the phantom experiment, we showed that our Haar feature-based EUS probe tracking method can find the best matched simulated EUS image from a simulated EUS dictionary which includes 123 simulated images. The errors of all four target points between the real EUS image and the best matched EUS images were within 1 mm. In the patient CT/MRI scans, the best matched simulated EUS image was selected by our method accurately, thereby confirming the probe location. However, when applying our method in MRI images, our method is not always robust due to the low image resolution.ConclusionsOur Haar feature-based method is capable to find the best matched simulated EUS image from the dictionary. We demonstrated the feasibility of our method for tracking EUS probe without external tracking hardware, thereby guiding the hydrogel injection between the head of the pancreas and duodenum.
Sensory systems must continuously adapt to optimally encode stimuli encountered within the natural environment. The prevailing view is that such optimal coding comes at the cost of increased ambiguity, yet to date, prior studies have focused on artificial stimuli. Accordingly, here we investigated whether such a trade-off between optimality and ambiguity exists in the encoding of natural stimuli in the vestibular system. We recorded vestibular nuclei and their target vestibular thalamocortical neurons during naturalistic and artificial self-motion stimulation. Surprisingly, we found no trade-off between optimality and ambiguity. Using computational methods, we demonstrate that thalamocortical neural adaptation in the form of contrast gain control actually reduces coding ambiguity without compromising the optimality of coding under naturalistic but not artificial stimulation. Thus, taken together, our results challenge the common wisdom that adaptation leads to ambiguity and instead suggest an essential role in underlying unambiguous optimized encoding of natural stimuli.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.