PurposeThis study was aimed to compare the clinical, functional, and radiographic outcomes between symmetric and asymmetric extension and mediolateral gap balance after navigation‐assisted (NA) total knee arthroplasty (TKA) using ultracongruent (UC) insets and the medial stabilising technique (MST).
MethodsIn all, 363 knees of 275 patients who underwent mechanical alignment‐target NA TKA with MST between January 2015 and December 2017 were analysed. Patients were divided into balanced (extension mediolateral gap difference ≤ 2 mm) and tight medial (difference ≥ 3 mm) groups. Pre‐ and postoperative clinical, functional (range of motion, Western Ontario and McMaster University Osteoarthritis [WOMAC] index, Knee Society Knee Score [KSKS], and Knee Society Function Score [KSFS]) and radiographic (hip–knee–ankle [HKA] angle, femoral condylar offset, extension angle [a minus indicates hyperextension], and joint line distance) outcomes were compared between the groups. Student’s t‐ or Chi‐squared test was used to compare the outcomes.
ResultsAmong the 363 knees analysed, 279 (77%) were assigned to the balanced group and 84 (23%) to the tight medial group. The preoperative HKA angle was significantly greater in the tight medial group than in the balanced group (9.7° ± 4.1° vs 14.3° ± 4.7°, P < 0.001). The postoperative WOMAC index, KSKS, and KSFS were similar between the groups. The change in the joint line distance was not significantly different (1.5 ± 3.7 vs 2.0 ± 3.3; n.s).
ConclusionThe clinical, functional, and radiographic outcomes, including joint line distance, were comparable between the tight medial and balanced group after mechanical alignment‐targeted UC TKA with MST.
Level of evidenceLevel III, retrospective comparative study.
Background. Coronary artery disease (CAD) is considered as the leading cause of the cardiovascular fatalities worldwide. CAD is diagnosed by many modalities of imaging such as myocardial perfusion imaging (MPI) and coronary angiography (CAG). Methods. A retrospective cross-sectional study was conducted that included all patients referred to the KAMC (King Abdullah Medical City) nuclear cardiology lab from its opening until the end of May 2014 (a period of 17 months). A total of 228 patient reports with a history of conducting either CAG or MPI or both were used in this study and statistically analyzed. Results. An analysis of the MPI results revealed that 78.5% of the samples were abnormal. On the other hand, 26.75% of the samples revealed that they were subjected to CAG and MPI. There was a significant and fair agreement between MPI and CAG by using all the agreement coefficients (kappa = 0.237, phi = 0.310, and P value = 0.043). The sensitivity, specificity, and accuracy of MPI with reference to CAG were 97.8%, 20%, and 78.69%, respectively. In addition, positive predictive and negative predictive values were 78.95% and 75%, respectively. Conclusion. In a tertiary referral center, there was a significant agreement between MPI and CAG and a high accuracy of MPI. MPI was a noninvasive diagnostic test that could be used as a gatekeeper for CAG.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.