The role of biofeedback in blood pressure control remains ill-defined because of nonspecific (placebo) effects, small study numbers, and the technical limitations of continuous pressure feedback. Clarification of its potential is awaited by those seeking a nonpharmacological approach to blood pressure control. This study examines the capability for systolic pressure lowering of 5 mm Hg or more using continuous pressure feedback in a statistical sample of untreated, well-characterized, mildly hypertensive individuals. Subjects were randomized in a double-blind study to active or placebo biofeedback. Placebo consisted of a modified contingency approach, using a partial disguise based on a digital high pass filter with 15 elements. Blood pressure-lowering capability was assessed during two laboratory sessions. Continuous visual feedback resulted in 11 of 28 subjects on active treatment and 12 of 28 on placebo treatment lowering their systolic pressure by 5 mm Hg or more (11 +/- 5.6 and 12 +/- 8.4 mm Hg, respectively; P = NS). Prestudy pressure was well-matched (153 +/- 9/97 +/- 4 and 154 +/- 8/98 +/- 4 mm Hg, respectively). An initial small difference in diurnal profile did not change. These findings indicate that among mildly hypertensive individuals, almost half can lower systolic pressure at will for short periods. This capability is independent of the real or placebo nature of the feedback signal. We conclude that there is no specific short-term biofeedback pressure-lowering capability in hypertensive individuals. Further exploration is needed to determine whether specific components of the placebo effect can be delineated, whether personality characteristics influence the response, and whether further biofeedback training can alter the outcome.
A new tunable optical filter incorporated in a solar magrtetograph consists of an interference filter followed by three ataomatically controlled Fabry-P6rot interfcrometers. It has a spectral rcsolving power of 105, an angular resolution of 5" arc and a field angle of 30' arc for this spectral resolving power. By using auxiliary optics the angular resolution of the object may be improved at the expense of the angular field. Thus angular field ......... 6 arc rain (arc sec)-J. aL{gu]ar resolution It is operational over the range 400-650 nm and may be tuned through ~: 0.2 nm about the selected transmission band.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.