H e l m u t K a n t e r M i t 16 Abbildungen Herrn Prof. Dr. Gustav Hertz zum YO. Geburtstage gewidmet Inhaltsiibersicht Gerichtete Elektronenstrahlen mit einer Primarenergie von 10, 30, 50 und 70 keV werden an Al, Cu, Ag und Au gestreut und dabei die Energie-und Winkelverteilung der Streuelektronen gemessen. Aus den MeBergebnissen lassen sich fur einen Elektronenstrahler, der die Elektronen richtungsisotrop emittiert, die Energie-und Winkelverteilung der riickgestreuten Elektronen sowie der totale Riickstreukoeffizient errechnen. Die Ergebnisse dieser Rechnung werden mit den von anderen Autoren in verschiedenerlei Geometrie gemessenen Riickstreukoeffizienten verglichen. 10) H. R a n t e r , Marburger Diplomarbeit 1953.
For a current-driven Josephson junction shunted by an Ohmic resistance, the dc voltage response and impedance to external high-frequency currents is calculated with a second-order perturbation method based on the unperturbed solution for the time evolution of the voltage as given by Aslamazov and Larkin. The response is proportional to signal power and has three characteristic-frequency regions depending on whether the internal self-generated Josephson frequency, ω0, is larger than, equal to, or smaller than the signal frequency, ω. For ω0< or >ω the response could be expressed by easily observable parameters of the dc voltage-current characteristics. This permits comparison of the predictions with experimental results obtained on point-contact junctions whose dc characteristics were only approximately represented by the simple model chosen for analysis. For ω0≪ω the response is found to be proportional to (i) the slope of the dc characteristic, (ii) the inverse square of the applied frequency, (iii) the inverse battery current in terms of the critical current, and (iv) the voltage amplitude of the inherent Josephson oscillations. For ω0≫ω ``classical'' detection proportional to curvature is obtained. For ω0∼ω resonance detection occurs, which depends to a considerable degree on fluctuations of the average contact voltage. These predictions are in reasonable agreement with experiments in which point-contact junctions were illuminated with klystron radiation at 10 and 90 GHz. Evidence is presented that the voltage fluctuations limiting the resonance response are the result of noise generated in the junction. Comparison of the noise-equivalent power expected from the simple model with measured results suggests that parasitic elements, such as shunt capacity, are not negligible at 90 GHz.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.