This paper describes a method of obtaining the temporal and frequency response of avalanche photodiodes (APD) by performing simple noise measurements. From the measured noise spectrum and by using the Hilbert transformation technique, the complex transfer function of the detector is determined. response can then easily be calculated by means of fast Fourier transforming. The method has been applied on a high speed APD, with a bandwidth of ~2 GHz, and on a relatively slow APD, with a bandwidth of 0.2 GHz, to calculate the pulse response from a short optical pulse. The calculated pulse width for the fast APD was 215 psec, and the corresponding measured width was 210 psec, while for the slow APD the calculated and the measured widths both were 3.1 nsec. Also the shapes of the pulse responses showed excellent agreement. The method depends on the essentially identical frequency response of an APD and associated circuits for noise due to steady-state illumination and for a signal.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.