Introduction: In clinical practice, evaluation of postural control is based on the neurological examination, including Romberg's test, examination of gait and performance of pull test as part of the Unified Parkinson's Disease Rating Scale (UPDRS). The goal of our study was to identify posturographic parameters since quantitative technical methods for the measurement of postural control are not established in clinical routine yet. Methods: In this cross-sectional study design we examined patients with Parkinson's disease (PD) (Hoehn and Yahr < 3; PD n = 12) on a static posturographic platform (eyes open and eyes closed), performing a standard Romberg's test during neurological examination and compared the results with an age-matched healthy adult control (HAC n = 10) and a healthy young control (HYC n = 21). Results: In the platform Romberg's test with open eyes, the patients with PD showed a significantly greater mean sway [PD: 14.98 vs. HAC: 8.77 (mm), p < 0.003 vs. HYC 7.80 (mm)], greater mean radius [PD: 28.31 vs. HAC: 16.36 (mm), p < 0.008 vs. HYC: 14.19 (mm)] and greater marked area [PD: 2.38 vs. HAC: 0.88 (cm2), p < 0.016 vs. HYC: 0.78 (cm2)] compared to the HAC. The Romberg's test with closed eyes revealed a significantly greater mean sway [PD: 13.83 vs. HAC: 10.12 (mm), p < 0.033 vs. HYC: 5.82 (mm)] and greater mean radius [PD: 25.03 vs. HAC: 18.15 (mm), p < 0.045 vs. HYC: 9.11 (mm)] compared to both groups. Conclusions: The platform Romberg-test with closed eyes detected significant differences in elderly people and patients with Parkinson's disease, which could be objectively quantified with static posturography testing. Age alone showed significant changes, only detectable with closed eyes. Therefore, balance testing with a new computerized approach could help to identify balance problems in a geriatric assessment in clinical routine, especially with the parameters marked area and mean sway.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.