Bioabsorbable calcium sulphate antibiotic beads may be a useful addition for TMA for patients with non-healing diabetic ulcerations of the forefoot. The single-stage procedure could have a significant impact on the management of diabetic forefoot ulcerations by preventing additional hospital stays, improving the patient's quality of life and minimizing cost.
Previously, we developed a balloon transducer to measure the constraint of the pericardium (i.e., pericardial pressure) on the surface of the heart. It was validated physiologically in that it was shown to measure a pressure equal to the difference between the left ventricular end-diastolic pressure measured before and after pericardiectomy at the same left ventricular volume. To define its static operating characteristics, we loaded the balloon nonuniformly with weights that covered fractions of the balloon surface and found that the balloon accurately recorded the average stress if the stress was applied over at least 23% of its surface. To test its performance when curved, we placed it in large and small cylinders (minimum diameter 31 mm) and found that the balloon accurately recorded the stress. To define its dynamic operating characteristics, we applied sinusoidal stresses and found that its frequency response was limited only by that of the connecting catheter. When better dynamic response is required, we introduce a micromanometer-tipped catheter to obtain a unity-gain frequency response that is flat to 200 Hz.
To determine whether pericardial liquid pressure accurately measures pericardial constraint, we developed a technique in which a catheter was positioned perpendicular to the epicardial surface. This device, which occupies little or no pericardial space, couples the thin film of liquid to a transducer. In six open-chest dogs, we also measured left ventricular (LV) end-diastolic pressure (LVEDP) and anteroposterior and septum-to-free wall diameters. LVEDP was raised incrementally to approximately 25 mmHg by saline infusion. With the use of the product of the two diameters as an index of area (A(LV)), LVEDP-A(LV) relationships were obtained with the pericardium closed and again after the pericardium had been widely opened to obtain the isovolumic difference in LVEDP (DeltaLVEDP). In all dogs, the technique yielded values of pericardial pressure equal to DeltaLVEDP as well as equal to that measured using a previously placed balloon transducer in the same location and at the same A(LV). We conclude that, when the pressure of the pericardial liquid is appropriately measured, it (in addition to the balloon-measured contact stress) defines the diastolic constraining effect of the pericardium. Furthermore, we suggest that earlier measurements of pericardial "liquid pressure" were low, due to an artifact of measurement.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.