Renal size is an important parameter in the assessment of renal disease in dogs. However, because of the great variability in body conformation, absolute renal measurements cannot solely be used when evaluating kidneys with ultrasonography. The use of a ratio comparing renal length and aortic luminal diameter (K/Ao) was investigated. After confirming the reproducibility of these measurements, K/Ao ratios were obtained in 92 dogs without clinical evidence of renal disease. Left and right K/Ao ratios were statistically similar. Based on 95% confidence intervals, renal size should be considered reduced if the K/Ao ratio is < 5.5 and increased when > 9.1.
Canine elbow incongruence is believed to be the consequence of underdevelopment of the radius. The purpose of this study is to determine the sensitivity and specificity of radiography to detect elbow incongruence in an in vitro model and to assess the optimal elbow angle and radiographic beam position. Five normal cadaveric canine left forelimbs were used. A four-pin, type 1 external fixator with a linear motor side bar was fixed to the cranial part of the radius of each limb and a 1 cm segment of bone was removed from the mid-diaphysis to allow radial shortening. Each elbow was subjected to the same protocol. They were radiographed at two different angles (90 degrees and 135 degrees) of flexion, with 10 different radiographic beam positions (centered on the humeral condyle, 3 cm cranial, 3 cm caudal, 3 cm distal, 3 cm proximal, 3 cm cranio-proximal, 3 cm cranio-distal, 3 cm caudo-proximal, 3 cm caudo-distal and on the shoulder joint) and at four different level of radial shortening (0, 1, 2 and 3 mm). In addition, a radiographic view centered on the elbows flexed at 135 degrees was made after simulating weight bearing. The acquired digital images were independently evaluated by three evaluators unaware of the elbows status. The elbows were judged normal, incongruent or borderline based on specific criteria. The sensitivity for detection of elbow incongruence at and beyond 2 mm was excellent at 90 degrees (median = 100% for all views) and good at 135 degrees (median = 80%) of flexion with no difference between examiners. The sensitivity at 1 mm of incongruence was unchanged at 135 degrees but was reduced at 90 degrees of flexion (median = 60%) with a significant difference between the evaluators. The specificity was significantly different between the evaluators and ranged from 70% to 90% at 90 degrees of flexion and from 50% to 80% at 135 degrees. The lowest specificities at 90 degrees were obtained with the proximal displacements of the X-ray beam. Simulating weight bearing significantly decreased the sensitivity at 1 mm (from 80% to 50%) and 3 mm (from 100% to 80%) of incongruence and slightly increased the specificity (from 55% to 65%). Radiography is a sensitive and specific test to detect moderate-to-severe radio-ulnar incongruence (2 mm and over) if the elbow is flexed at a 90 degrees angle regardless of the radiographic beam position. Finally, canine elbow incongruence appeared reduced after an in vitro weight-bearing simulation.
Radiation-inactivation studies were performed on brush-border-membrane vesicles purified from rat kidney cortex. No alteration of the structural integrity of the vesicles was apparent in electron micrographs of irradiated and unirradiated vesicles. The size distributions of the vesicles were also similar for both populations. The molecular sizes of two-brush-border-membrane enzymes, alkaline phosphatase and 5'-nucleotidase, estimated by the radiation-inactivation technique, were 104800 +/- 3500 and 89,400 +/- 1800 Da respectively. Polyacrylamide-gel-electrophoresis patterns of membrane proteins remained unaltered by the radiation treatment, except in the region of higher-molecular-mass proteins, where destruction of the proteins was visible. The molecular size of two of these proteins was estimated from their mobilities in polyacrylamide gels and was similar to the target size, estimated from densitometric scanning of the gel. Intravesicular volume, estimated by the uptake of D-glucose at equilibrium, was unaffected by irradiation. Uptake of Na+, D-glucose and phosphate were measured in initial-rate conditions to avoid artifacts arising from a decrease in the driving force caused by a modification of membrane permeability. Na+-independent D-glucose and phosphate uptakes were totally unaffected in the dose range used (0-9 Mrad). The Na+-dependent uptake of D-glucose was studied in irradiated vesicles, and the molecular size of the transporter was found to be 288,000 Da. The size of the Na+-dependent phosphate carrier was also estimated, and a value of 234,000 Da was obtained.
Lumbosacral discospondylitis may not respond well to conservative treatment because of the mobility of the affected space. Surgical treatment involving distraction and stabilization to obtain intervertebral fusion is very effective in treating lumbosacral instability caused by discospondylitis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.