Ferahame when conjugated with protamine and heparin was cytotoxic at the higher and lower doses, as revealed by the XTT assay. Endorem and FluidMag-L were not toxic at the studied concentrations. Feraheme non-conjugated solutions and Lumirem solutions provided were harmless but were not internalized by ARPE-19 cells. All the studied nanoparticles were attracted to the magnetic field except Feraheme in the non-conjugated form.
Endothelial keratoplasty has been adopted by corneal surgeons worldwide as an alternative to penetrating keratoplasty (PK) in the treatment of corneal endothelial disorders. Since the first surgeries in 1998, different surgical techniques have been used to replace the diseased endothelium. Compared with penetrating keratoplasty, all these techniques may provide faster and better visual rehabilitation with minimal change in refractive power of the transplanted cornea, minimal induced astigmatism, elimination of suture-induced complications and late wound dehiscence, and a reduced demand for postoperative care. Translational research involving cell-based therapy is the next step in work on endothelial keratoplasty. The present review updates information on comparisons among different techniques and predicts the direction of future treatment.
Análise da pressão intra-ocular após ceratectomia fotorrefrativa com excimer laser Objetivo: Comparar os valores pré-operatórios da pressão intraocular (Po) com os valores pós-operatórios em pacientes submetidos à ceratectomia fotorrefrativa com excimer laser, bem como, avaliar os efeitos do uso de corticosteróide tópico na Po nesse grupo.Pacientes e métodos: Foram analisados retrospectivamente 122 pacientes submetidos à ceratectomia fotorrefrativa com excimer laser para correção de miopia, no período de fevereiro de 1994 a dezembro de 1996. Esse grupo teve sua Po tomada com o tonômetro de aplanação de Goldmann no pré-operatório, 30º e 60º dias e sexto mês pós-operatório. Receberam cuidados pós-operatórios padronizados, incluindo o uso de corticosteróide tópico. Resultados: Foi observado um aumento estatisticamente significante em relação aos valores pré-operatórios nas médias da Po no 30º dia pós-operatório, ao passo que no pós-operatório de seis meses obteve-se diminuição estatisticamente significante nos valores médios da Po em relação ao pré-operatório.Conclusão: Nas fases iniciais do período pré-operatório, observou-se um aumento da Po possivelmente relacionado ao uso de corticosteróides. Após 6 meses, os valores da Po foram estatisticamente menores que os pré-operatórios.
OBJECTIVE: To assess the usefulness of corneal esthesiometry for screening diabetic retinopathy. METHODS: A cross-sectional study was carried out comprising 575 patients attending a diabetic retinopathy-screening program in the city of São Paulo. Corneal esthesiometry was assessed with the Cochet-Bonnet esthesiometer. The presence of diabetic retinopathy was detected with indirect fundoscopy. The validity of corneal esthesiometry in identifying diabetic retinopathy was evaluated by the Receiver Operating Characteristic (ROC) curve. RESULTS: Sensitivity and specificity analyses of the corneal esthesiometry for detecting the stages of diabetic retinopathy using different cut-offs showed values less than 80%. The best indices (72.2% sensitivity and 57.4% specificity) were obtained for the identification of patients with proliferative diabetic retinopathy. CONCLUSIONS: In the study series, corneal esthesiometry was not a good indicator of diabetic retinopathy.
RESUMOObjetivo:Na última década os computadores de mão se popularizaram entre profissionais da saúde. Nos EUA, por exemplo, cerca de 60-70% dos estudantes de medicina já os utilizam. A disponibilização de informação clínica nestes dispositivos pode auxiliar no ensino de práticas médicas, no entanto, a maneira como são estruturadas pode influenciar na satisfação e no aprendizado dos alunos. Portanto, este artigo objetiva apresentar os resultados da avaliação do MDFluxo: um programa para auxílio ao ensino de oftalmologia em computadores de mão. Métodos: O programa foi desenvolvido com fluxogramas estruturados, extraídos do Guia de Oftalmologia da Universidade Federal de São Paulo. A avaliação foi realizada, comparando o desempenho de 20 estudantes de medicina na solução de casos clínicos, utilizando o programa, o livro ou nenhum material. Resultados: Os resultados mostram que o desempenho dos estudantes na avaliação com o livro foi equivalente ao MDFluxo nas questões sobre etiologia (p<0,01) e conduta (p<0,05) na solução dos casos clínicos, desempenho melhor do que sem a utilização de nenhum material. Conclusão: Na avaliação de satisfação com o uso do programa 82,5% dos estudantes aprovou sua utilização na solução de casos clínicos.
Descritores
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.