Introduction:Preanalytical errors, along the process from the beginning of test requests to the admissions of the specimens to the laboratory, cause the rejection of samples. The aim of this study was to better explain the reasons of rejected samples, regarding to their rates in certain test groups in our laboratory.Materials and methods:This preliminary study was designed on the rejected samples in one-year period, based on the rates and types of inappropriateness. Test requests and blood samples of clinical chemistry, immunoassay, hematology, glycated hemoglobin, coagulation and erythrocyte sedimentation rate test units were evaluated. Types of inappropriateness were evaluated as follows: improperly labelled samples, hemolysed, clotted specimen, insufficient volume of specimen and total request errors.Results:A total of 5,183,582 test requests from 1,035,743 blood collection tubes were considered. The total rejection rate was 0.65 %. The rejection rate of coagulation group was significantly higher (2.28%) than the other test groups (P < 0.001) including insufficient volume of specimen error rate as 1.38%. Rejection rates of hemolysis, clotted specimen and insufficient volume of sample error were found to be 8%, 24% and 34%, respectively. Total request errors, particularly, for unintelligible requests were 32% of the total for inpatients.Conclusions:The errors were especially attributable to unintelligible requests of inappropriate test requests, improperly labelled samples for inpatients and blood drawing errors especially due to insufficient volume of specimens in a coagulation test group. Further studies should be performed after corrective and preventive actions to detect a possible decrease in rejecting samples.
This study has shown that maternal vitamin D deficiency is related with an increased risk of SGA delivery. Further studies are needed to explain the relationship with vitamin D deficiency and poor perinatal outcomes.
IL-37 was expressed in all biofluids. According to our findings, the total amount of IL-37 in gingival crevicular fluid, or salivary or plasma concentrations of IL-37, may not be useful diagnostic markers to differentiate periodontal disease and the periodontally healthy condition. The difference in gingival crevicular fluid IL-37 concentration between the study groups may be a result of the variation in gingival crevicular fluid volume, as suggested by the negative correlation between gingival crevicular fluid volume and gingival crevicular fluid IL-37 concentration. In the light of our findings, it seems that IL-37 is not involved in periodontal disease. Further comprehensive studies may clarify this issue more clearly.
Objective. This study was designed to investigate the impact of using suture material impregnated with platelet-rich plasma (PRP) in different platelet concentrations on colonic anastomotic wound healing in rats. Methods. A total of 24 Sprague Dawley female rats were separated into 3 groups (n=8 for each) including the control group (CON; standard vicryl suture repair), the low platelet concentrate PRP group (L-PRP; suture material impregnated with PRP containing average 2.7-fold (range, 2.0 to 3.1) higher amount of platelets vs. control), and the high platelet concentrate PRP group (H-PRP; suture material impregnated with PRP containing average 5.1-fold (range, 4.8 to 5.4) higher amount of platelets vs. control). Rats were sacrificed on the postoperative 7th day for analysis of colonic anastomosis region including macroscopic observation, measurement of anastomotic bursting pressure (ABP), and the hydroxyproline levels and histopathological findings in colon tissue samples. Results. Total injury scores were significantly lower in the L-PRP and H-PRP groups than those in the control group (median (range) 13.00 (7.00) and 11.50 (6.00) vs. 15.50 (4.00), p<0.05 and p<0.01, respectively). ABP values (180.00 (49.00) vs. 124.00 (62.00) and 121.00 (57.00) mmHg, p<0.001 for each) and tissue hydroxyproline levels (0.56 (0.37) vs. 0.25 (0.17) and 0.39 (0.10) μg/mg tissue, p<0.001 and p<0.05, respectively) were significantly higher in the L-PRP group as compared with those in the control and H-PRP groups. Conclusion. In conclusion, our findings revealed PRP application to colonic anastomosis sutures to promote the anastomotic healing process. The platelet concentration of PRP seems to have a significant impact on the outcome with superior efficacy of L-PRP over H-PRP in terms of bursting pressures and collagen concentration at the anastomotic site.
BACKGROUND:Pulmonary embolism (PE) is a common and potentially life-threatening disorder. Patients with PE often have nonspecific symptoms, and the diagnosis is often delayed.AIM:The aim of our study was to investigate the role of signal peptide-complement C1r/C1s, Uegf, and Bmp1-epidermal growth factor domain-containing protein 1 (SCUBE1) used in the diagnosis of PE.METHODS:The study was designed prospectively. A total of 57 patients who were admitted to emergency service with clinically suspected PE were included in the study. The patients diagnosed with PE were defined as PE group (n = 32), and the patients with undetectable embolism on computerized tomographic pulmonary angiography were defined as non-PE group (n = 25). Twenty-five age- and sex-matched healthy cases were chosen for the study. Routine biochemical analysis, complete blood count, D-dimer, SCUBE1, and arterial blood gas analysis were performed early after admission.RESULTS:Mean SCUBE1 levels were higher in the PE group (0.90 ng/mL) than in the non-PE (0.38 ng/mL) and control groups (0.47 ng/mL) (P < 0.01). A cutoff point of 0.49 ng/mL for SCUBE1 indicated 100% sensitivity and 64% specificity in patients with PE. Mean D-dimer levels were not different between PE and non-PE groups (P = 0.591). A multivariable logistic regression analysis (with dichotomous PE groups as the response variable; age, gender, chest pain, syncope, diabetes mellitus, chronic obstructive pulmonary disease, hypertension, D-dimer, neutrophil-lymphocytes ratio, and SCUBE1 variables as predictors) showed that the significant and independent predictors of PE diagnosis were SCUBE1 and chest pain.CONCLUSION:This study suggests that serum SCUBE1 measurement might be used as a diagnostic biomarker in PE.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.