PurposeWe sought to identify genes of clinical significance to predict survival and the risk for colorectal liver metastasis (CLM), the most common site of metastasis from colorectal cancer (CRC).Patients and MethodsWe profiled gene expression in 31 specimens from primary CRC and 32 unmatched specimens of CLM, and performed Significance Analysis of Microarrays (SAM) to identify genes differentially expressed between these two groups. To characterize the clinical relevance of two highly-ranked differentially-expressed genes, we analyzed the expression of secreted phosphoprotein 1 (SPP1 or osteopontin) and lymphoid enhancer factor-1 (LEF1) by immunohistochemistry using a tissue microarray (TMA) representing an independent set of 154 patients with primary CRC.ResultsSupervised analysis using SAM identified 963 genes with significantly higher expression in CLM compared to primary CRC, with a false discovery rate of <0.5%. TMA analysis showed SPP1 and LEF1 protein overexpression in 60% and 44% of CRC cases, respectively. Subsequent occurrence of CLM was significantly correlated with the overexpression of LEF1 (chi-square p = 0.042), but not SPP1 (p = 0.14). Kaplan Meier analysis revealed significantly worse survival in patients with overexpression of LEF1 (p<0.01), but not SPP1 (p = 0.11). Both univariate and multivariate analyses identified stage (p<0.0001) and LEF1 overexpression (p<0.05) as important prognostic markers, but not tumor grade or SPP1.ConclusionAmong genes differentially expressed between CLM and primary CRC, we demonstrate overexpression of LEF1 in primary CRC to be a prognostic factor for poor survival and increased risk for liver metastasis.
Monitoring blood loss is important for management of surgical patients. This study reviews a device (Triton) that uses computer analysis of a photograph to estimate hemoglobin (Hb) mass present on surgical sponges. The device essentially does what a clinician does when trying to make a visual estimation of blood loss by looking at a sponge, albeit with less subjective variation. The performance of the Triton system is reported upon in during real-time use in surgical procedures. The cumulative Hb losses estimated using the Triton system for 50 enrolled patients were compared with reference Hb measurements during the first quarter, half, three-quarters and full duration of the surgery. Additionally, the estimated blood loss (EBL) was calculated using the Triton measured Hb loss and compared with values obtained from both visual estimation and gravimetric measurements. Hb loss measured by Triton correlated with the reference method across the four measurement intervals. Bias remained low and increased from 0.1 g in the first quarter to 3.7 g at case completion. The limits of agreement remained narrow and increased proportionally from the beginning to the end of the cases, reaching a maximum range of -15.3 to 22.7 g. The median (IQR) difference of EBL derived from the Triton system, gravimetric method and visual estimation versus the reference value were 13 (74), 389 (287), and 4 (230) mL, respectively. Use of the Triton system to measure Hb loss in real-time during surgery is feasible and accurate.
The Triton Canister System was able to measure the Hb mass reliably with clinically acceptable accuracy in reconstituted blood samples representing a wide range of Hb concentrations, dilutions, hemolysis, and ambient lighting settings.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.