BACKGROUNDIn patients with type 1 diabetes who are not pregnant, closed-loop (automated) insulin delivery can provide better glycemic control than sensor-augmented pump therapy, but data are lacking on the efficacy, safety, and feasibility of closed-loop therapy during pregnancy. METHODSWe performed an open-label, randomized, crossover study comparing overnight closed-loop therapy with sensor-augmented pump therapy, followed by a continuation phase in which the closed-loop system was used day and night. Sixteen pregnant women with type 1 diabetes completed 4 weeks of closed-loop pump therapy (intervention) and sensor-augmented pump therapy (control) in random order. During the continuation phase, 14 of the participants used the closed-loop system day and night until delivery. The primary outcome was the percentage of time that overnight glucose levels were within the target range (63 to 140 mg per deciliter [3.5 to 7.8 mmol per liter]). RESULTSThe percentage of time that overnight glucose levels were in the target range was higher during closed-loop therapy than during control therapy (74.7% vs. 59.5%; absolute difference, 15.2 percentage points; 95% confidence interval, 6.1 to 24.2; P = 0.002). The overnight mean glucose level was lower during closed-loop therapy than during control therapy (119 vs. 133 mg per deciliter [6.6 vs. 7.4 mmol per liter], P = 0.009). There were no significant differences between closed-loop and control therapy in the percentage of time in which glucose levels were below the target range (1.3% and 1.9%, respectively; P = 0.28), in insulin doses, or in adverseevent rates. During the continuation phase (up to 14.6 additional weeks, including antenatal hospitalizations, labor, and delivery), glucose levels were in the target range 68.7% of the time; the mean glucose level was 126 mg per deciliter (7.0 mmol per liter). No episodes of severe hypoglycemia requiring third-party assistance occurred during either phase. CONCLUSIONSOvernight closed-loop therapy resulted in better glucose control than sensor-augmented pump therapy in pregnant women with type 1 diabetes. Women receiving day-and-night closed-loop therapy maintained glycemic control during a high proportion of the time in a period that encompassed antenatal hospital admission, labor, and delivery.
Supplemental Digital Content is available in the text.
BackgroundPatients with chronic heart failure (HF) secondary to left ventricular systolic dysfunction (LVSD) are frequently deficient in vitamin D. Low vitamin D levels are associated with a worse prognosis.ObjectivesThe VINDICATE (VitamIN D treatIng patients with Chronic heArT failurE) study was undertaken to establish safety and efficacy of high-dose 25 (OH) vitamin D3 (cholecalciferol) supplementation in patients with chronic HF due to LVSD.MethodsWe enrolled 229 patients (179 men) with chronic HF due to LVSD and vitamin D deficiency (cholecalciferol <50 nmol/l [<20 ng/ml]). Participants were allocated to 1 year of vitamin D3 supplementation (4,000 IU [100 μg] daily) or matching non−calcium-based placebo. The primary endpoint was change in 6-minute walk distance between baseline and 12 months. Secondary endpoints included change in LV ejection fraction at 1 year, and safety measures of renal function and serum calcium concentration assessed every 3 months.ResultsOne year of high-dose vitamin D3 supplementation did not improve 6-min walk distance at 1 year, but was associated with a significant improvement in cardiac function (LV ejection fraction +6.07% [95% confidence interval (CI): 3.20 to 8.95; p < 0.0001]); and a reversal of LV remodeling (LV end diastolic diameter -2.49 mm [95% CI: -4.09 to -0.90; p = 0.002] and LV end systolic diameter -2.09 mm [95% CI: -4.11 to -0.06 p = 0.043]).ConclusionsOne year of 100 μg daily vitamin D3 supplementation does not improve 6-min walk distance but has beneficial effects on LV structure and function in patients on contemporary optimal medical therapy. Further studies are necessary to determine whether these translate to improvements in outcomes. (VitamIN D Treating patIents With Chronic heArT failurE [VINDICATE]; NCT01619891)
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.