Elaboration of Bayesian phylogenetic inference methods has continued at pace in recent years with major new advances in nearly all aspects of the joint modelling of evolutionary data. It is increasingly appreciated that some evolutionary questions can only be adequately answered by combining evidence from multiple independent sources of data, including genome sequences, sampling dates, phenotypic data, radiocarbon dates, fossil occurrences, and biogeographic range information among others. Including all relevant data into a single joint model is very challenging both conceptually and computationally. Advanced computational software packages that allow robust development of compatible (sub-)models which can be composed into a full model hierarchy have played a key role in these developments. Developing such software frameworks is increasingly a major scientific activity in its own right, and comes with specific challenges, from practical software design, development and engineering challenges to statistical and conceptual modelling challenges. BEAST 2 is one such computational software platform, and was first announced over 4 years ago. Here we describe a series of major new developments in the BEAST 2 core platform and model hierarchy that have occurred since the first release of the software, culminating in the recent 2.5 release.
The focus of this article is a Bayesian method for inferring both species delimitations and species trees under the multispecies coalescent model using molecular sequences from multiple loci. The species delimitation requires no a priori assignment of individuals to species, and no guide tree. The method is implemented in a package called STACEY for BEAST2, and is a extension of the author's DISSECT package. Here we demonstrate considerable efficiency improvements by using three new operators for sampling from the posterior using the Markov chain Monte Carlo algorithm, and by using a model for the population size parameters along the branches of the species tree which allows these parameters to be integrated out. The correctness of the moves is demonstrated by tests of the implementation. The practice of using a pipeline approach to species delimitation under the multispecies coalescent, has been shown to have major problems on simulated data (Olave et al. in Syst Biol 63:263-271. doi: 10.1093/sysbio/syt106 , 2014). The same simulated data set is used to demonstrate the accuracy and improved convergence of the present method. We also compare performance with *BEAST for a fixed delimitation analysis on a large data set, and again show improved convergence.
No abstract
BACKGROUND: Proficiency testing (PT), or external quality assessment (EQA), is intended to verify on a recurring basis that laboratory results conform to expectations for the quality required for patient care.CONTENT: Key factors for interpreting PT/EQA results are knowledge of the commutability of the samples used and the process used for target value assignment. A commutable PT/EQA sample demonstrates the same numeric relationship between different measurement procedures as that expected for patients' samples. Noncommutable PT/EQA samples frequently have a matrix-related bias of unknown magnitude that limits interpretation of results. PT/EQA results for commutable samples can be used to assess accuracy against a reference measurement procedure or a designated comparison method. In addition, the agreement of the results between different measurement procedures for commutable samples reflects that which would be seen for patients' samples. PT/EQA results for noncommutable samples must be compared to a peer group mean/ median of results from participants who use measurement procedures that are expected to have the same or very similar matrix-related bias. Peer group evaluation is used to asses whether a laboratory is using a measurement procedure in conformance to the manufacturer's specifications and/or in conformance to other laboratories using the same technology. A noncommutable PT/EQA sample does not give meaningful information about the relationship of results for patients' samples between different measurement procedures.
Reference intervals are a vital part of the information supplied by clinical laboratories to support interpretation of numerical pathology results such as are produced in clinical chemistry and hematology laboratories. The traditional method for establishing reference intervals, known as the direct approach, is based on collecting samples from members of a preselected reference population, making the measurements and then determining the intervals. An alternative approach is to perform analysis of results generated as part of routine pathology testing and using appropriate statistical techniques to determine reference intervals. This is known as the indirect approach. This paper from a working group of the International Federation of Clinical Chemistry (IFCC) Committee on Reference Intervals and Decision Limits (C-RIDL) aims to summarize current thinking on indirect approaches to reference intervals. The indirect approach has some major potential advantages compared with direct methods. The processes are faster, cheaper and do not involve patient inconvenience, discomfort or the risks associated with generating new patient health information. Indirect methods also use the same preanalytical and analytical techniques used for patient management and can provide very large numbers for assessment. Limitations to the indirect methods include possible effects of diseased subpopulations on the derived interval. The IFCC C-RIDL aims to encourage the use of indirect methods to establish and verify reference intervals, to promote publication of such intervals with clear explanation of the process used and also to support the development of improved statistical techniques for these studies.
Supplementary data are available at Bioinformatics online.
electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modication of the content of the paper are prohibited. Additional information:Use policyThe full-text may be used and/or reproduced, and given to third parties in any format or medium, without prior permission or charge, for personal research or study, educational, or not-for-prot purposes provided that:• a full bibliographic reference is made to the original source • a link is made to the metadata record in DRO • the full-text is not changed in any way The full-text must not be sold in any format or medium without the formal permission of the copyright holders.Please consult the full DRO policy for further details. ABSTRACTStereoscopic images are hard to get right, and comfortable images are often only produced after repeated trial and error. The main difficulty is controlling the stereoscopic camera parameters so that the viewer does not experience eye strain or double images from excessive perceived depth. Additionally, for head tracked displays, the perceived objects can distort as the viewer moves to look around the displayed scene. We describe a novel method for calculating stereoscopic camera parameters with the following contributions:(1) Provides the user intuitive controls related to easily measured physical values. (2) For head tracked displays; necessarily ensures that there is no depth distortion as the viewer moves. (3) Clearly separates the image capture camera/scene space from the image viewing viewer/display space. (4) Provides a transformation between these two spaces allowing precise control of the mapping of scene depth to perceived display depth.The new method is implemented as an API extension for use with OpenGL, a plug-in for 3D Studio Max and a control system for a stereoscopic digital camera. The result is stereoscopic images generated correctly at the first attempt, with precisely controlled perceived depth. A new analysis of the distortions introduced by different camera parameters was undertaken.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.