Early markers of cardiac disease including hypertrophy and diastolic dysfunction of the left ventricle are present in youths with obesity prior to the development of sustained hypertension.
Background: It is unclear whether the heart is affected in pediatric patients with milder forms of spinal muscular atrophy (SMA). Therefore, we aimed to determine the presence of any cardiac abnormalities in these patients. Methods: We conducted a cross-sectional study of children and adolescents with SMA types 2 and 3 between July 2018 and July 2019. All patients underwent a comprehensive cardiac evaluation, including history-taking, physical examination, electrocardiography, echocardiography, measurement of cardiac biomarkers (cardiac troponin T [cTnT] and N-terminal pro-brain natriuretic peptide [NT-proBNP]), and 24-hour Holter monitoring. Results: In total, 42 patients were enrolled (27 and 15 with SMA type 2 and 3, respectively). No patient had structural heart disease, except for one with mitral valve prolapse. None had signs of ventricular dysfunction on echocardiography. Both cTnT and NT-proBNP levels were normal in all patients. Electrocardiography showed sinus tachycardia in seven patients (16.7%), and prolonged P-R interval in one (2.4%). Holter monitoring detected benign ventricular arrhythmias in two patients (4.8%), and rare supraventricular premature beats in one. The mean 24-hour heart rate was elevated in six patients (14.3%), whereas both the minimum 24-hour heart rate and the maximum R-R interval were increased in 23 (54.8%).
Oral propranolol for IHs does not remarkably affect heart rhythm including circadian variations throughout hospital initiation. Therefore, there is no necessity for Holter monitoring in additional safety assessment.
BackgroundThe Electrocardiogram ECG is one of the most important non-invasive tools for cardiac diseases diagnosis. Taking advantage of the developed telecommunication infrastructure, several approaches that address the development of telemetry cardiac devices were introduced recently. Telemetry ECG devices allow easy and fast ECG monitoring of patients with suspected cardiac issues. Choosing the right device with the desired working mode, signal quality, and the device cost are still the main obstacles to massive usage of these devices.MethodsIn this paper, we introduce design, implementation, and validation of a multi-purpose telemetry system for recording, transmission, and interpretation of ECG signals in different recording modes. The system consists of an ECG device, a cloud-based analysis pipeline, and accompanied mobile applications for physicians and patients. The proposed ECG device’s mechanical design allows laypersons to easily record post-event short-term ECG signals, using dry electrodes without any preparation. Moreover, patients can use the device to record long-term signals in loop and holter modes, using wet electrodes. In order to overcome the problem of signal quality fluctuation due to using different electrodes types and different placements on subject’s chest, customized ECG signal processing and interpretation pipeline is presented for each working mode.ResultsWe present the evaluation of the novel short-term recorder design. Recording of an ECG signal was performed for 391 patients using a standard 12-leads golden standard ECG and the proposed patient-activated short-term post-event recorder. In the validation phase, a sample of validation signals followed peer review process wherein two experts annotated the signals in terms of signal acceptability for diagnosis.We found that 96% of signals allow detecting arrhythmia and other signal’s abnormal changes. Additionally, we compared and presented the correlation coefficient and the automatic QRS delineation results of both short-term post-event recorder and 12-leads golden standard ECG recorder.ConclusionsThe proposed multi-purpose ECG device allows physicians to choose the working mode of the same device according to the patient status. The proposed device was designed to allow patients to manage the technical requirements of both working modes. Post-event short-term ECG recording using the proposed design provide physicians reliable three ECG leads with direct symptom-rhythm correlation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.