Ankle joint kinematics is mainly stabilized by the morphology of the talar dome and the articular surface of tibiofibular mortise as well as the medial and lateral ligament complexes. Because of this the bicondylar geometry of talus dome is believed to be crucial for ankle implant design. However, little data exist describing the precise anatomy of the talar dome and the talocrural joint axis. The aim of this study is to document the anatomy of the talar dome and the axis of the talocrural joint using three-dimensional (3D) computed tomographic (CT) modeling. Seventy-one participants enrolled for CT scanning and 3D talar model reconstruction. All the ankles were held in a neutral position during the CT scanning. Six points on the lateral and medial crest of the talar dome were defined. The coordinate of the six points; radii of lateral-anterior (R-LA), lateral-posterior (R-LP), medial-anterior (R-MA), and medial-posterior (R-MP) sections; and inclination angle of the talar dome were measured, and the inclination and deviation angles of the talocrural joint axis were determined. The mean values of R-LA, R-LP, R-MA, and R-MP were 19.23 ± 2.47 mm, 18.76 ± 2.90 mm, 17.02 ± 3.49 mm, and 22.75 ± 3.04 mm. The mean inclination angle of the talar dome was 9.86 ± 3.30 degrees. Gender variation was found in this parameter. The mean inclination and deviation angles were 8.60 ± 0.07 and 0.76 ± 0.69 degrees for the dorsiflexion axis and −7.34 ± 0.07 and 0.09 ± 0.18 degrees for the plantarflexion axis. Bilateral asymmetries between the medial and lateral crest of the talar dome were found, which resulted in different dorsiflexion and plantarflexion axes of the talocrural joint. Currently, no ankle implants replicate this talar anatomy, and these findings should be considered in future implant designs.
PurposeMounting evidence highlights the essential role of TRIM44 in tumor initiation and malignant progression in several cancers; however, the function of TRIM44 in osteosarcoma (OS) remains unknown. In this study, we aim to investigate the role of TRIM44 and reveal its regulation by deregulated miRNAs in OS.Materials and methodsThe expression profiles of TRIM44 were examined by immunohistochemistry, Western blotting, and qRT-PCR. The biological functions of TRIM44 were investigated through siRNA-mediated knockdown experiments. The regulation of TRIM44 by miR-410 was confirmed by Western blotting, dual luciferase reporter assays, and rescue experiments.ResultsTRIM44 was upregulated in OS tissues and cell lines, and its overexpression was positively correlated with TNM stage, metastasis, and recurrence. Knockdown of TRIM44 in OS cells suppressed cell proliferation, migration, invasion, and epithelial–mesenchymal transition. In addition, we identified TRIM44 as a novel target gene of miR-410 and miR-410 was remarkably downregulated in OS. Moreover, overexpression of miR-410 suppressed proliferation, migration, invasion, and epithelial–mesenchymal transition of OS cells by directly targeting TRIM44 expression. Furthermore, reintroduction of TRIM44 partially reversed miR-410-induced inhibitory effects on OS cells.ConclusionCollectively, our findings indicate that the miR-410/TRIM44 link is critical in the control of OS progression.
An ankle brace is commonly used by patients after they suffer from initial ankle sprains, reducing the incidents of recurrent sprain or limiting laxity in joints with functional ankle instability (FAI). However, whether the application of a semirigid ankle brace can improve the abnormal ankle gait kinematics of patients with FAI remains unknown. This study aimed to determine the effect of a semirigid ankle brace on the gait kinematics of ankle joints through 3D-2D fluoroscopy image registration. A total of 8 subjects with FAI (3 males and 5 females, 10 feet) as FAI group and 10 subjects without FAI (6 males and 4 females, 10 feet) as control group were enrolled in this study. Three-dimensional bone models created from computed tomography images were matched to fluoroscopic images to compute the 6 degrees of freedom (DOF) talocrural, subtalar, and ankle joints complex kinematics for control and FAI group with or without brace during the stance phase of walking. FAI patients had significantly less ROMs in inversion/eversion rotation of the talocrural and subtalar joint after wearing semirigid ankle brace. Laxity was observed in most of the displacements of the talocrural and subtalar joints in FAI group. The brace partly altered the ankle joints movement in opposite directions, especially joint rotation, and restricted the talocrural and subtalar joints in the dorsiflexion position during the touch down phase of walking.
Understanding the shape of superior talar dome is essential for a better size compatibility between talar component of ankle implant and bone. The purpose of this study was to determine whether there were gender variations in (1) width (TW) and length (TL) of talus, as well as anterior width (DAW), middle width (DMW), posterior width (DPW), and length (DL) of superior talar dome; (2) differences between the DAW, DMW, and DPW; (3) the ratios between these parameters. Fifty-one cadaveric ankle specimens were included. Two observers measured all the specimens using vernier caliper. Intraclass correlation coefficients (ICCs) were used for intraobserver and interobserver reliability analysis and the reliability was thought to be good if the ICC>0.75. A two-tailed unpaired t-test or the rank-sum test was used to investigate gender variations. A single-factor ANOVA was utilized to identify the differences between the width of the superior talar dome surface and p value of <0.05 was considered significant. Intraobserver and interobserver reliability were good. Significant gender variations were found, in which TW, TL, DAW, DMW, DPW, and DL of female specimens were much smaller than those of male. The width of talar dome linearly decreased from DAW to DPW; however, the linearly decreased rate from anterior to posterior width was bigger in female. Moreover, significant differences were found in DAW/DPW, DMW/DPW, DL/DAW, DL/DMW, and DL/DPW between male and female. Based on our result, there was no difference in the 2D shape of the whole talus instead gender variation existed in the 2D shape of superior talar dome between male and female. The current 2D data could contribute to figure out more suitable size of talar component for Chinese population and might indicate a gender-specific shape of bone-implant interface, which could reduce the potential bone-component incompatibility when performing ankle replacement using standard component.
Purpose: This study was designed to investigate (1) the contour of the distal tibial cutting surface, and (2) the bone mineral density (BMD) of the distal tibial cutting surface used during total ankle arthroplasty (TAA). Methods: Eight-four distal tibial models were created using foot and ankle computerized tomographic (CT) images taken from normal people. The distal tibial cutting surface for TAA was determined to be 10 mm proximal to the tibial plafond. The bony contour and BMD values were determined from the CT image at that level. A bounding box was made on the contour and the width and length of the contour was measured. Regional BMD was evaluated by Hounsfield units (HU) value measurement, with 7 regions of interest (ROI) on 8 different directions for all the 84 CT images. Two different observers made independent measurements and mean HU values for all the 56 ROIs were calculated. Results: Great variations were found among the contours of the cutting surface especially in term of the shape of the anterior and posterior tibial tubercle, and the fibular notch. These variations could be grouped into six categories. For the BMD of the cutting surface, the medial border of the cutting surface did not included cortical bone. The HU value of seven ROIs, which included cortical bone, were significantly greater than all the other ROIs. Few statistical differences were found by multiple comparisons among HU value of all the 49 ROIs without cortex. Conclusions: Great variability existed in the shape and the BMD of the distal tibial cutting surface.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.