Background-Patients with left ventricular dysfunction have an elevated risk of sudden cardiac death. However, the substrate for ventricular arrhythmia in patients with nonischemic cardiomyopathy remains poorly understood. We hypothesized that the distribution of scar identified by MRI is predictive of inducible ventricular tachycardia. Methods and Results-Short-axis cine steady-state free-precession and postcontrast inversion-recovery gradient-echo MRI sequences were obtained before electrophysiological study in 26 patients with nonischemic cardiomyopathy. Left ventricular ejection fraction was measured from end-diastolic and end-systolic cine images. The transmural extent of scar as a percentage of wall thickness (percent scar transmurality) in each of 12 radial sectors per slice was calculated in all myocardial slices. The percentages of sectors with 1% to 25%, 26% to 50%, 51% to 75%, and 76% to 100% scar transmurality were determined for each patient. Predominance of scar distribution involving 26% to 75% of wall thickness was significantly predictive of inducible ventricular tachycardia and remained independently predictive in the multivariable model after adjustment for left ventricular ejection fraction (odds ratio, 9.125; Pϭ0.020).
Conclusions-MR
Background-MRI has unparalleled soft-tissue imaging capabilities. The presence of devices such as pacemakers and implantable cardioverter/defibrillators (ICDs), however, is historically considered a contraindication to MRI. These devices are now smaller, with less magnetic material and improved electromagnetic interference protection. Our aim was to determine whether these modern systems can be used in an MR environment. Methods and Results-We tested in vitro and in vivo lead heating, device function, force acting on the device, and image distortion at 1.5 T. Clinical MR protocols and in vivo measurements yielded temperature changes Ͻ0.5°C. Older (manufactured before 2000) ICDs were damaged by the MR scans. Newer ICD systems and most pacemakers, however, were not. The maximal force acting on newer devices was Ͻ100 g. Modern (manufactured after 2000) ICD systems were implanted in dogs (nϭ18), and after 4 weeks, 3-to 4-hour MR scans were performed (nϭ15). No device dysfunction occurred. The images were of high quality with distortion dependent on the scan sequence and plane. Pacing threshold and intracardiac electrogram amplitude were unchanged over the 8 weeks, except in 1 animal that, after MRI, had a transient (Ͻ12 hours) capture failure. Pathological data of the scanned animals revealed very limited necrosis or fibrosis at the tip of the lead area, which was not different from controls (nϭ3) not subjected to MRI.
Conclusions-These
Radiofrequency ablation can be evaluated accurately by using gadolinium-enhanced MRI, which may allow the noninvasive assessment of procedural success. The dissimilar wash-in and wash-out kinetics compared with myocardial infarction suggest a different pathophysiological process with complete loss of microvasculature.
Background-Compared with fluoroscopy, the current imaging standard of care for guidance of electrophysiology procedures, magnetic resonance imaging (MRI) provides improved soft-tissue resolution and eliminates radiation exposure. However, because of inherent magnetic forces and electromagnetic interference, the MRI environment poses challenges for electrophysiology procedures. In this study, we sought to test the feasibility of performing electrophysiology studies with real-time MRI guidance. Methods and Results-An MRI-compatible electrophysiology system was developed. Catheters were targeted to the right atrium, His bundle, and right ventricle of 10 mongrel dogs (23 to 32 kg) via a 1.5-T MRI system using rapidly acquired fast gradient-echo images (Ϸ5 frames per second). Catheters were successfully positioned at the right atrial, His bundle, and right ventricular target sites of all animals. Comprehensive electrophysiology studies with recording of intracardiac electrograms and atrial and ventricular pacing were performed. Postprocedural pathological evaluation revealed no evidence of thermal injury to the myocardium. After proof of safety in animal studies, limited real-time MRI-guided catheter mapping studies were performed in 2 patients. Adequate target catheter localization was confirmed via recording of intracardiac electrograms in both patients. Conclusions-To the best of our knowledge, this is the first study to report the feasibility of real-time MRI-guided electrophysiology procedures. This technique may eliminate patient and staff radiation exposure and improve real-time soft tissue resolution for procedural guidance.
The results of this study demonstrate the potential utility of wireless monitoring systems in the follow-up of AF ablation patients, while also identifying poor patient compliance with an intensive monitoring protocol as an important limitation.
Background-This study sought to define the technique and results of magnetic resonance imaging (MRI) of pulmonary vein (PV) anatomy before and after catheter ablation of atrial fibrillation (AF). Methods and Results-Twenty-eight patients with AF underwent ablation. Patients underwent gadolinium-enhanced MRI before and 6 weeks after their procedures. A control group of 27 patients also underwent MRI. Variant PV anatomy was observed in 38% of patients. AF patients had larger PV diameters than control subjects, but no difference was observed in the size of the PV ostia among AF patients. The PV ostia were oblong in shape with an anteroposterior dimension less than the superoinferior dimension. The left PVs had a longer "neck" than the right PVs. A detectable PV narrowing was observed in 24% of veins. The severity of stenosis was severe in 1 vein (1.4%), moderate in 1 vein (1.4%), and mild in 15 veins (21.1%). All patients were asymptomatic, and none required treatment. Conclusions-This study demonstrates that AF patient have larger PVs than control subjects and demonstrates the value of MRI in facilitating AF ablation. The benefits of preprocedural MRI of PVs include the ability to evaluate the number, size, and shape of the PVs. MRI also provides an assessment of the severity of PV stenosis.
The results of this study demonstrate that detectable PV narrowing occurs in 38% of PVs following anatomic PV ablation. Moderate or severe PV stenosis occurs in 3.8% of PVs. The high incidence of mild stenosis likely reflects reverse remodeling rather than pathological PV stenosis. The probability of moderate or severe PV stenosis appears to be related to creation of individual encircling rather than encircling in pairs lesion.
These data support the hypothesis that histopathologically benign mucosa of the upper aerodigestive tract may harbor foci of clonal, preneoplastic cells that are genetically related to metastatic HNSCC and that such mucosal sites are the sites of origin of unknown primary HNSCC. Microsatellite analysis may represent a clinically useful tool for determining such sites.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.