Background After cerebral ischemia, disruption and subsequent reorganization of functional connections occur both locally and remote to the lesion. Recently, complexity of brain connectivity has been described using graph theory, a mathematical approach that depicts important properties of complex systems by quantifying topologies of network representations. Functional and dynamic changes of brain connectivity can be reliably analyzed via electroencephalography (EEG) recordings even when they are not yet reflected in structural changes of connections. Objective We tested whether and how ischemic stroke in the acute stage may determine changes in small-worldness of cortical networks as measured by cortical sources of EEG. Methods Graph characteristics of EEG of 30 consecutive stroke patients in acute stage (no more than 5 days after the event) were examined. Connectivity analysis was performed using eLORETA in both hemispheres. Results Network rearrangements were mainly detected in delta, theta, and alpha bands when patients were compared with healthy subjects. In delta and alpha bands similar findings were observed in both hemispheres regardless of the side of ischemic lesion: bilaterally decreased small-worldness in the delta band and bilaterally increased small-worldness in the alpha2 band. In the theta band, bilaterally decreased small-worldness was observed only in patients with stroke in the left hemisphere. Conclusions After an acute stroke, brain cortex rearranges its network connections diffusely, in a frequency-dependent modality probably in order to face the new anatomical and functional frame.
BackgroundStroke units provide patients with a multiparametric monitoring of vital functions, while no instruments are actually available for a continuous monitoring of patients motor performance. Our aim was to develop an actigraphic index able both to identify the paretic limb and continuously monitor the motor performance of stroke patients in the stroke unit environment.MethodsTwenty consecutive acute stroke patients (mean age 69.2 years SD 10.1, 8 males and 12 females) and 17 bed-restrained patients (mean age 70.5 years SD 7.3, 7 males and 10 females) hospitalized for orthopedic diseases of the lower limbs, but not experiencing neurological symptoms, were enrolled. This last group represented our control group. The motor activity of arms was recorded for 24 h using two programmable actigraphic systems showing off as wrist-worn watches. The firmware segmented the acquisition in epochs of 1 minute and for each epoch calculates two motor activity indices: MAe1 (Epoch-related Motor Activity index) and MAe2 (Epoch-related Motor Activity index 2). MAe1 is defined as the standard deviation of the acceleration module and MAe2 as the module of the standard deviation of acceleration components. To describe the 24 h motor performance of each limb, we calculated the mean value of MAe1 and MAe2 (respectively MA1_24h and MA2_24h). Then we obtained two Asymmetry Rate Indices: AR1_24h and AR2_24h to show the motor activity prevalence. AR1_24h refers to the asymmetry index between the values of MAe1 of both arms and AR2_24h to MAe2 values.The stroke patients were clinically evaluated by NIHSS at the beginning (NIHSST0) and at the end (NIHSST1) of the 24 h actigraphic recordings.ResultsBoth MA1_24h and MA2_24h indices were smaller in the paretic than in the unaffected arm (respectively p = 0.004 and p = 0.004). AR2_24h showed a better capability (95% of paretic arms correctly identified, Phi Coefficient: 0.903) to discriminate the laterality of the clinical deficit than AR1_24h (85% of paretic arms correctly identified, Phi Coefficient: 0,698). We also found that AR1_24h did not differ between the two groups of patients while AR2_24h was greater in stroke patients than in controls and positively correlated with NIHSS total scores (r: 0.714, p < 0.001 for NIHSS, IC95%: 0.42–0.90) and with the sub-score relative to the paretic upper limb (r: 0.812, p < 0.001, IC95%: 0.62–0.96).ConclusionsOur data show that actigraphic monitoring of upper limbs can detect the laterality of the motor deficit and measure the clinical severity. These findings suggest that the above described actigraphic system could implement the existing multiparametric monitoring in stroke units.
Purpose: To investigate whether prefrontal cortex (PFC) functioning during ataxic gait is linked to compensatory mechanisms or to the typical intra-subject variability of the ataxic gait. Methods: Nineteen patients with chronic ataxia and fifteen healthy subjects were evaluated. The subjects were requested to walk along a straight distance of 10 meters while PFC oxygenation and gait parameters were assessed. PFC activity was evaluated by NIRO-200 while gait analysis was performed by the SMART-D500. To investigate the intra-subject variability of gait, we calculated the coefficient of multiple correlation (CMC) of the hip, knee and ankle kinematic waveforms furthermore, we evaluated the step width. Results: We observed a positive correlation between PFC bilateral oxygenation changes and the step width (r = 0.54; p = 0.02 for the right PFC, and r = 0.50; p = 0.03 for the left PFC). No correlation was found between PFC activity and CMC of the hip, knee and ankle waveforms. Conclusions: Our results suggest that PFC activity is linked to gait compensatory mechanisms more than to the variability of the joint kinematic parameters caused by a defective cerebellar control.
The estimate of a consistent and clinically meaningful joint kinematics using wearable inertial and magnetic sensors requires a sensor-to-segment coordinate system calibration. State-of-the-art calibration procedures for the upper limb are based on functional movements and/or pre-determined postures, which are difficult to implement in subjects that have impaired mobility or are bedridden in acute units. The aim of this study was to develop and validate an alternative calibration procedure based on the direct identification of palpable anatomical landmarks (ALs) for an inertial and magnetic sensor-based upper limb movement analysis protocol. The proposed calibration procedure provides an estimate of three-dimensional shoulder/elbow angular kinematics and the linear trajectory of the wrist according to the standards proposed by the International Society of Biomechanics. The validity of the method was assessed against a camera-based optoelectronic system during uniaxial joint rotations and a reach-to-grasp task. Joint angular kinematics was found as characterised by a low-biased range of motion (<−2.6°), a low root mean square deviation (RMSD) (<4.4°) and a high waveform similarity coefficient (R2 > 0.995) with respect to the gold standard. Except for the cranio–caudal direction, the linear trajectory of the wrist was characterised by a low-biased range of motion (<11 mm) together with a low RMSD (8 mm) and high waveform similarity (R2 > 0.968). The proposed method enabled the estimation of reliable joint kinematics without requiring any active involvement of the patient during the calibration procedure, complying with the metrological standards and requirements of clinical movement analysis.
Background. Patients suffering from cerebellar ataxia have extremely variable gait kinematic features. We investigated whether and how wearable inertial sensors can describe the gait kinematic features among ataxic patients. Methods. We enrolled 17 patients and 16 matched control subjects. We acquired data by means of an inertial sensor attached to an ergonomic belt around pelvis, which was connected to a portable computer via Bluetooth. Recordings of all the patients were obtained during overground walking. From the accelerometric data, we obtained the harmonic ratio (HR), i.e., a measure of the acceleration patterns, smoothness and rhythm, and the step length coefficient of variation (CV), which evaluates the variability of the gait cycle. Results. Compared to controls, patients had a lower HR, meaning a less harmonic and rhythmic acceleration pattern of the trunk, and a higher step length CV, indicating a more variable step length. Both HR and step length CV showed a high effect size in distinguishing patients and controls (p < 0.001 and p = 0.011, respectively). A positive correlation was found between the step length CV and both the number of falls (R = 0.672; p = 0.003) and the clinical severity (ICARS: R = 0.494; p = 0.044; SARA: R = 0.680; p = 0.003). Conclusion. These findings demonstrate that the use of inertial sensors is effective in evaluating gait and balance impairment among ataxic patients.
Background: It is often challenging to formulate a reliable prognosis for patients with acute ischemic stroke. The most accepted prognostic factors may not be sufficient to predict the recovery process. In this view, describing the evolution of motor deficits over time via sensors might be useful for strengthening the prognostic model. Our aim was to assess whether an actigraphic-based parameter (Asymmetry Rate Index for the 24 h period (AR2_24 h)) obtained in the acute stroke phase could be a predictor of a 90 d prognosis. Methods: In this observational study, we recorded and analyzed the 24 h upper limb movement asymmetry of 20 consecutive patients with acute ischemic stroke during their stay in a stroke unit. We recorded the motor activity of both arms using two programmable actigraphic systems positioned on patients’ wrists. We clinically evaluated the stroke patients by NIHSS in the acute phase and then assessed them across 90 days using the modified Rankin Scale (mRS). Results: We found that the AR2_24 h parameter positively correlates with the 90 d mRS (r = 0.69, p < 0.001). Moreover, we found that an AR2_24 h > 32% predicts a poorer outcome (90 d mRS > 2), with sensitivity = 100% and specificity = 89%. Conclusions: Sensor-based parameters might provide useful information for predicting ischemic stroke prognosis in the acute phase.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.