Purpose Revision of a shoulder arthroplasty to a reverse arthroplasty is a highly demanding procedure. The aim of this study is to report the clinical results of hemi and total shoulder prosthesis revisions to reverse implants without removal of the humeral stem, using a modular shoulder replacement system (SMR Lima LTD). We retrospectively reviewed 26 patients who underwent an operation from 2004 to 2009. Methods The patients were divided into two groups: in Group I, 18 patients underwent a revision of hemiarthroplasty implanted for fracture; in Group II, eight patients underwent a revision of anatomical total prosthesis. All patients were evaluated at a mean follow-up of 32.3 (±12.7) months using the Constant score rating scale and by range of motion evaluation, EQ-VAS, X-ray and CT scan. Results The Constant score of each patient was 47.88 (±5.88) after the revision. The EQ-VAS improved from 40 (±20) to 70 (±10). All patients improved in terms of range of motion.The radiographs and CT scans obtained after revision showed good integration and no signs of loosening of the implant. The mean time of surgery was recorded as 62′ (±8′), with a maximum blood loss of less than 300 ml in all cases. Conclusions Our study demonstrates that using a full modular system at the time of the first implant allows avoidance of the step to remove the humeral stem and metal back in cases of shoulder prosthesis revision to a reverse prosthesis, resulting in a short operative time, few intraoperative complications and a satisfactory clinical outcome at medium-term follow-up.
CFR-PEEK plates proved as reliable as metallic plates in the treatment of proximal humeral fractures. The advantages of these new devices include a better visualization of fracture reduction during intraoperative fluoroscopic assessment and easy hardware removal due to the absence of screw-plate cold fusion.
The study findings indicate that the biomimetic scaffold that was investigated is an off-the-shelf, cell-free, and cost-effective implant that can regenerate either cartilage or subchondral bone. The scaffold allows a 1-step surgical procedure that can be used for osteochondral lesions, OCD, and in some cases osteonecrosis.
Unrepairable comminuted fractures of the radial head Mason type III or type IV have poor outcomes when treated by open reduction and internal fixation. Radial head resection has been proposed as good option for surgical treatment, while in the last decades, the development of technology and design in radial head prosthesis has increased efficacy in prosthetic replacement. The present review was conducted to determine the best surgical treatment for comminuted radial head when ORIF is not possible. Better outcomes are reported for radial head arthroplasty in terms of elbow stability, range of motion, pain, and fewer complications compared to radial head excision. Nevertheless, radial head resection still can be considered an option of treatment in isolated radial head fractures with no associated ligament injuries lesion of ligaments or in case of older patients with low demanding function.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.