Neuroendocrine tumours displaying somatostatin receptors have been successfully visualised with somatostatin receptor imaging (SRI). However, there may be differences in sensitivity depending on the site of the primary tumour and/or its metastases. We studied 131 patients affected by neuroendocrine tumours of the gastro-entero-pancreatic (GEP) tract. A pathological diagnosis was obtained in 116 patients, while in 15 the diagnosis was based on instrumental results and follow-up. Fifty-one patients were examined for staging purposes, 80 were in follow-up. Images were acquired 24 and 48 h after the injection of 150-220 MBq of indium-111 pentetreotide. Whole-body and SPET images were obtained in all patients. Patients were also studied with computed tomography (CT), ultrasound (US), and other procedures. Tumours were classified according to their site of origin: pancreas n = 39, ileum n = 32, stomach n = 16, appendix n = 9, duodenum n = 5, jejunum n = 5, rectum n = 3, biliary tract n = 2, colon n = 2, caecum n = 1, liver metastases from unknown primary = 15, widespread metastases from unknown primary = 2. Sensitivity for primary tumour localisation was as follows: SRI = 62%; CT = 43%; US = 36%; other procedures = 45%. Sensitivity for liver metastases: SRI = 90%; CT = 78%; US = 88%; other procedures = 71%. Sensitivity for the detection of extrahepatic soft tissue lesions was: SRI = 90%; CT = 66%; US = 47%; other procedures = 61%. Sensitivity for the detection of the primary tumour in patients with metastases from unknown primary sites: SRI 4/17; CT 0/13; US 0/12; other procedures 1/10. In 28% of the patients SRI revealed previously unknown lesions, and in 21% it determined a modification of the scheduled therapy. Our study confirms the important role of SRI in the management of GEP tumours. However, we feel that a critical investigation should address its role in locating primary tumours, in particular in patients with metastases from unknown primary sites.
for the CoViD-19 Lombardia Team OBJECTIVES: The aims of this study are to report the prevalence of delirium on admission to the unit in patients hospitalized with SARS-CoV-2 infection, to identify the factors associated with delirium, and to evaluate the association between delirium and in-hospital mortality. DESIGN: Multicenter observational cohort study. SETTINGS: Acute medical units in four Italian hospitals. PARTICIPANTS: A total of 516 patients (median age 78 years) admitted to the participating centers with SARS-CoV-2 infection from February 22 to May 17, 2020. MEASUREMENTS: Comprehensive medical assessment with detailed history, physical examinations, functional status, laboratory and imaging procedures. On admission, delirium was determined by the Diagnostic and Statistical Manual of Mental Disorders (5th edition) criteria, 4AT, m-Richmond Agitation Sedation Scale, or clinical impression depending on the site. The primary outcomes were delirium rates and in-hospital mortality. RESULTS: Overall, 73 (14.1%, 95% confidence interval (CI) = 11.0-17.3%) patients presented delirium on admission. Factors significantly associated with delirium were dementia (odds ratio, OR = 4.66, 95% CI = 2.03-10.69), the number of chronic diseases (OR = 1.20, 95% CI = 1.03; 1.40), and chest X-ray or CT opacity (OR = 3.29, 95% CI = 1.12-9.64 and 3.35, 95% CI = 1.07-10.47, for multiple or bilateral opacities and single opacity vs no opacity, respectively). There were 148 (33.4%) in-hospital deaths in the no-delirium group and 43 (58.9%) in the delirium group (P-value assessed using the Gray test <.001). As assessed by a multivariable Cox model, patients with delirium on admission showed an almost twofold increased hazard ratio for in-hospital mortality with respect to patients without delirium (hazard ratio = 1.88, 95% CI = 1.25-2.83). CONCLUSION: Delirium is prevalent and associated with in-hospital mortality among older patients hospitalized with SARS-CoV-2 infection.
Our results indicate that F-18 FDG-PET/CT is a useful diagnostic tool in patients with differentiated thyroid carcinoma and with negative I-131 total body scans and high Tg levels. The levothyroxine therapy regimen does not influence F-18 FDG-PET/CT results and the rate of F-18 FDG-PET/CT positive results appears to correlate with the Tg levels. The highest accuracy is reached when the study is performed for patients with Tg levels higher than 21 ng/mL.
Considering the similarities with other pandemics due to respiratory virus infections and subsequent development of neurological disorders (e.g. encephalitis lethargica after the 1918 influenza), there is growing concern about a possible new wave of neurological complications following the worldwide spread of SARS-CoV-2. However, data on COVID-19-related encephalitis and movement disorders are still limited. Herein, we describe the clinical and neuroimaging (FDG-PET/CT, MRI and DaT-SPECT) findings of two patients with COVID-19-related encephalopathy who developed prominent parkinsonism. None of the patients had previous history of parkinsonian signs/symptoms, and none had prodromal features of Parkinson’s disease (hyposmia or RBD). Both developed a rapidly progressive form of atypical parkinsonism along with distinctive features suggestive of encephalitis. A possible immune-mediated etiology was suggested in Patient 2 by the presence of CSF-restricted oligoclonal bands, but none of the patients responded favorably to immunotherapy. Interestingly, FDG-PET/CT findings were similar in both cases and reminiscent of those observed in post-encephalitic parkinsonism, with cortical hypo-metabolism associated with hyper-metabolism in the brainstem, mesial temporal lobes, and basal ganglia. Patient’s FDG-PET/CT findings were validated by performing a Statistical Parametric Mapping analysis and comparing the results with a cohort of healthy controls ( n = 48). Cerebrum cortical thickness map was obtained in Patient 1 from MRI examinations to evaluate the structural correlates of the metabolic alterations detected with FDG-PET/CT. Hypermetabolic areas correlated with brain regions showing increased cortical thickness, suggesting their involvement during the inflammatory process. Overall, these observations suggest that SARS-CoV-2 infection may trigger an encephalitis with prominent parkinsonism and distinctive brain metabolic alterations.
We recently demonstrated in a clinical trial the ability of a new protocol, IQ SPECT, to acquire myocardial perfusion imaging (MPI) studies in a quarter of the time (12 s/view) of the standard protocol, with preserved diagnostic accuracy. We now aim to establish the lower limit of radioactivity that can be administered to patients and the minimum acquisition time in SPECT MPI using an IQ SPECT protocol, while preserving diagnostic accuracy. Methods: An anthropomorphic cardiac phantom was used to acquire clinical rest scans with a simulated in vivo distribution of 99m Tc-tetrofosmin at full dose (740 MBq) and at doses equal to 50%, 25%, and 18%. For each dose, 2 sets of images were acquired, with and without a transmural defect (TD). Variable acquisition times were also used for each dose. We analyzed raw data and reconstructed images, including no correction and correction for attenuation (AC), for scatter (SC), or for both (ACSC). Images were evaluated qualitatively and quantitatively in order to assess left ventricle (LV) wall thickness (full width at half maximum of the medial sections), TD, and cavity contrast in the LV wall. Data were compared across different acquisition times within the same dose and across doses with the same acquisition time. Results: Images were visually scored as very-good quality except those acquired with 4 s/view or less at 100% dose and 6 s/view or less with 50%, 25%, or 18% dose, due to falsepositive defects. LV wall thickness was not significantly different among all acquisitions. Cavity contrast remained unchanged within the same dose for all images and tended to be higher in AC and ACSC images. TD contrast remained unchanged within the same dose for all images. In SC and no-correction images, contrast was constant for all doses. AC images had significantly higher TD contrast values, and ACSC images showed a drop in TD contrast for a 50% dose. Conclusion: IQ SPECT effectively preserved both image quality and quantitative measurements with reduced acquisition time or administered dose in a phantom study. These findings suggest that approximately one eighth of the time, compared with standard protocols with a full dose, or a lower dose at an acquisition time of 12 s/view can be applied in MPI without the loss of diagnostic accuracy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.