The aim of this article is to show the use of the Balters' Bionator in pseudo-Class III treatment. The importance of differentiating between true Class III and pseudo-Class III is emphasized. The therapeutic results of a Balters' Bionator appliance are presented in three case reports of subjects in the mixed dentition. In this stage of development it is possible to correct an isolated problem. The use of the Bionator III in this kind of malocclusion enabled the correction of a dental malocclusion in a few months and therapeutic stability of a mesially-positioned mandible encouraging favourable skeletal growth.
In open bite case treatments, a proper diagnostic differentiation is essential in determining the appropriate corrective procedures. Dental open bites are generally more responsive to treatment with orthodontics alone, whereas skeletal open bites often require a combination of orthodontics and orthognathic surgery. Patient selection and treatment principles for non-surgical open bite treatment routinely include fixed appliances both labial or lingual. However, removable clear aligners have gained a consistent popularity in the treatment of complex cases including open bite malocclusions. In this article, the authors describe three different clinical cases in which open bite cases had been satisfactorily treated by using clear aligners.
Background The purpose of the in vitro study is to investigate and compare the morphological features and the chemical stability in weight of two different polyurethane-based blends, Smart Track (LD30) and Exceed30 (EX30), used for orthodontic aligners manufacture before and after the oral usage. Methods Twenty orthodontic aligners were randomly selected: 10 LD30 and 10 EX30, each group was divided in two subgroups, never used and intra-orally aged. By the employment of a Stereomicroscope, a section of 5 × 5 mm was cut from the buccal surface of the incisal region of each aligner. All samples were subjected to Scanning Electron Microscopy and Ageing tests in different solutions to simulate the hostility of the oral environment. The statistical method used was t-test. Results At SEM images, LD30 appears more homogeneous in texture respect to EX30. However, after clinical usage, both materials show significant structural alterations: findings have been supported by higher magnifications at SEM, by which it is clearly to observe many superficial cracks cross through the polymer structures of LD30U, absent in never used samples. LD30U surface becomes also smoother due to the disappearance of most of the conglomerates, but at the same time also rougher while EX30U shows a greater irregularity and porosity in which large and deep cracks are also highlighted. Although these changes occur persistently, in the aging tests no significant weight loss from both materials has been found, confirming the initial hypothesis of a good chemical stability and safety of both polyurethane mixtures even in conditions of severe hostility. Conclusion LD30 is the expression of the technological evolution of EX30, this is made evident above all by its morphological architecture, more homogeneous and defined but also by the chemical stability that can be appreciated even in evident critic situations.
BackgroundThe aim of the present investigation was to evaluate enamel reduction efficiency, abrasive property decay, and enamel effects between oscillating mechanical and manual systems for interproximal enamel reduction (IPR).MethodsThree oscillating strips and three manual strips were tested on twelve freshly extracted premolars blocked in an acrylic cylinder pot by means of a material testing machine. Each strip underwent one test of 8 cycles (30 s each). Both abrasive tracks and teeth surfaces were qualitative evaluated before and after IPR by means of SEM analysis. Efficiency and abrasive property decay of both IPR systems were investigated by the amount of enamel reduction within the eight-cycle testing. Independent t-test was used to evaluate differences in variables between the two systems.ResultsMechanical IPR system showed higher efficiency in terms of enamel reduction (p < 0.005) when compared with manual IPR system (0.16 mm and 0.09 mm, respectively). Quantity of removed enamel decreased throughout the 8 cycles for both systems. Less presence of enamel debris and detachment of abrasive grains were observed on mechanical strips rather than manual strips. SEM analysis revealed more regular surface of teeth undergone mechanical IPR procedures.ConclusionOscillating diamond strips showed more controlled efficiency when compared with the manual IPR system leading to a more regular enamel surface.
Bacterial adhesion to the surface of orthodontic materials is an important step in the formation and proliferation of plaque bacteria, which is responsible for enamel demineralization and periodontium pathologies. With the intent of investigating if adhesive resins used for bracket bonding are prone to bacteria colonization, the surface roughness of these materials has been analyzed, combining information with a novel methodology to observe the internal structures of orthodontic composites. Scanning electron microscopy, combined with focus ion bean micromachining and stylus profilometry analyses, were performed to evaluate the compositional factors that can influence specific pivotal properties facilitating the adhesion of bacteria to the surface, such as surface roughness and robustness of three orthodontic adhesive composite resins. To confirm these findings, contact angle measurements and bacteria incubation on resin slide have been performed, evaluating similarities and differences in the final achievement. In particular, the morphological features that determine an increase in the resins surface wettability and influence the bacterial adhesion are the subject of speculation. Finally, the focused ion beam technique has been proposed as a valuable tool to combine information coming from surface roughness with specific the internal structures of the polymers.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.