Dislocation is one of the most common complications of total hip arthroplasty (THA). To the authors' knowledge, late recurrent dislocation of a THA with a ceramic-on-ceramic coupling secondary to fatigue fracture of the ceramic liner has never been described. A 76-year-old woman with right hip osteoarthritis underwent cementless modular THA with a ceramic-on-ceramic coupling. Approximately 10 years postoperatively, she experienced right hip pain with no trauma, which resolved in 14 days. Family members reported that the patient had shown a progressive cognitive and muscular decline in the previous months. Six months later, the patient was admitted for THA dislocation, which was immediately reduced. Computed tomography revealed that the right acetabular component had a retroversion of 4° and an inclination angle of 45°. An orthopedic brace was applied, but dislocation recurred 2 days after discharge. A 3-dimensional CT reconstruction showed a fracture of the ceramic liner in the posterolateral region. The patient underwent revision surgery, and the ceramic liner breakage was confirmed. After removal of the acetabular components, a cemented polyethylene cup was implanted. The stability of the stem was verified. The existing modular neck was replaced with a chromium-cobalt neck, and a new ceramic head was applied. At 7-month follow-up, the patient had good functional recovery with no hip instability. Fatigue failure of a ceramic liner should be considered as responsible for late dislocation after ceramic-on-ceramic THA. As part of the diagnostic strategy, 3-dimensional CT reconstruction should be used to evaluate ceramic liner breakage.
Total hip arthroplasty (THA) is a highly effective surgical treatment for severe joint involvement. However, due to the release of metal ions in the blood, the patients who undergo hip replacement with metal-on-metal (MOM) bearings may develop signs of allergic skin disease. We report a case of a 60-year-old man who had received MOM hip resurfacing 5 years earlier for osteoarthritis. He presented with a 3-year history of diffuse dermatitis that did not respond to antihistamines and corticosteroids and also had elevated serum levels of chromium and cobalt. A patch test revealed chromium-sulfate hypersensitivity. A skin biopsy showed nonspecific perivascular lymphocytic infiltrate associated with histiocytes. A biopsy of an inguinal lymph node demonstrated large aggregates of Langerhans cells, suggesting type IV delayed-type hypersensitivity. The prosthesis was replaced using ceramic-on-ceramic bearings and the dermatitis resolved after 3 months. The lymph nodes decreased in volume and the serum chromium levels normalized within 24 months of revision surgery. The high levels of serum ions associated with the metal debris from MOM-THAs may induce sensitization and type IV hypersensitivity reactions. Replacing the prosthesis using alternative coupling surfaces is the only approach that has the capacity to resolve these symptoms. Physicians who are not familiar with this issue may misdiagnose systemic symptoms and provide inadequate treatment.
Background: During the COVID-19 emergency, the incidence of fragility fractures in elderly patients remained unchanged. The management of these patients requires a multidisciplinary approach. The study aimed to assess the best surgical approach to treat COVID-19 patients with femoral neck fracture undergoing hemiarthroplasty (HA), comparing direct lateral (DL) versus direct anterior approach (DAA). Methods: A single-center, observational retrospective study including 50 patients affected by COVID-19 infection (30 males, 20 females) who underwent HA between April 2020 to April 2021 was performed. The patients were allocated into two groups according to the surgical approach used: lateral approach and anterior approach. For each patient, the data were recorded: age, sex, BMI, comorbidity, oxygen saturation (SpO2), fraction of the inspired oxygen (FiO2), type of ventilation invasive or non-invasive, HHb, P/F ratio (PaO2/FiO2), hemoglobin level the day of surgery and 1 day post operative, surgical time, Nottingham Hip Fractures Score (NHFS) and American Society of Anesthesiologists Score (ASA). The patients were observed from one hour before surgery until 48 h post-surgery of follow-up. The patients were stratified into five groups according to Alhazzani scores. A non-COVID-19 group of patients, as the control, was finally introduced. Results: A lateral position led to a better level of oxygenation (p < 0.01), compared to the supine anterior approach. We observed a better post-operative P/F ratio and a reduced need for invasive ventilation in patients lying in the lateral position. A statistically significant reduction in the surgical time emerged in patients treated with DAA (p < 0.01). Patients within the DAA group had a significantly lower blood loss compared to direct lateral approach. Conclusions: DL approach with lateral decubitus seems to preserved respiratory function in HA surgery. Thus, the lateral position may be associated with beneficial effects on gas exchange.
Transient lateral patellar dislocation (TLPD) is a common lesion in young adults. Vascular injury as a complication of TLPD has not been previously described. We report a case of descending genicular artery (DGA) injury after TLPD. Immediate angiography demonstrated rupture of DGA. Embolization was performed with sudden interruption of bleeding. DGA injury should be considered as a complication after TLPD and prompt diagnosis and intervention are required. We propose selective embolization as a safe and effective procedure to stop bleeding.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.